Estimating PMSG Wind Turbines by Inertia and Droop Control Schemes with Intelligent Fuzzy Controller in Indian Development

  • Josephine, R.L.;Suja, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1196-1201
    • /
    • 2014
  • This paper presents an exploration on the effect of wind turbine contribution to the frequency control of individual systems that can be used for efficient power production in India. The research includes the study of Permanent Magnet Synchronous Generator (PMSG), in wind farms. The WTs are tested for inertia and for droop responses with intelligent fuzzy logic controllers (FLC) that choose Double Input Single Output (DISO) strategy that automatically sets gain constants, as well as combined responses for the WTs. Quantitative analyses are presented for the WTs for benefits and drawbacks including appropriate selection parameters. The analysis includes inertia, droop and combined inertia, droop schemes. The reconnaissance also incorporates inertia with FLC, droop with FLC, inertia and droop with FLC schemes for detailed study of WTs, so as to forecast and achieve proper frequency control. Moreover, the analysis provides the best suited method for frequency control in PMSG.

Capacity Optimizing method of Distributed Generators in Stand-Alone Microgrid Considering Grid Link-Characteristics

  • Han, Soo-Kyeong;Choi, Hyeong-Jin;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1483-1493
    • /
    • 2018
  • Recently, more power facilities are needed to cope with the increasing electric demand. However, the additional construction of generators, transmission and distribution installations is not easy because of environmental problems and citizen's complaints. Under this circumstance, a microgrid system with distributed renewable resources emerges as an alternative of the traditional power systems. Moreover, the configuration of power system changes with more DC loads and more DC installations. This paper is written to introduce an idea of a genetic algorithm-based solution to determine the optimal capacity of the distributed generators depending on the types of system configuration: AC-link, DC-link and Hybrid-link types. In this paper, photovoltaic, wind turbine, energy storage system and diesel generator are considered as distributed generators and the feasibility of the proposed algorithm is verified by comparing the calculated capacity of each distributed resource with HOMER simulation results for 3 types of system configuration.

Fuzzy Control Strategy for Damping Sub-Synchronous Resonance

  • Qader, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1791-1797
    • /
    • 2018
  • Sub-Synchronous Resonance (SSR) is a phenomenon that harms turbine generator shafts because the phenomenon induces sub-synchronous wavering in the system. In the study presented in this paper, a dynamic resistance bank is used to mitigate the occurrence of sub-synchronous phenomenon. A fuzzy logic controller using rotor speed deviation and its derivative as inputs is implemented to damp sub-synchronous oscillations more efficiently. An eigenvalue technique is used to analyse the stability of the system, and a simulation in MATLAB is conducted, based on the IEEE Second Benchmark, to validate the effectiveness of the proposed method under a 3-phase fault condition at an infinite bus. The time-domain simulation and eigenvalues are used to observe the proposed method's superior ability to damp sub-synchronous oscillation.

Analysis of On-Line Partial Discharge Trend in High Voltage Motors (고압전동기 운전중 부분방전 추이 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Chung-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1472-1473
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) measurements were peformed with turbine generator analyzer(TGA) in two high voltage motors(rated 6.6 kV). These high voltage motors were installed with 80 pF capacitive couplers at the terminal box. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude (Qm). The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in stator windings of high voltage motors.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

Calculation of Rotor Loss according to analysis of Harmonics for Permanent Magnet High Speed Motor (영구자석 고속모터의 고조파 분석을 통한 회전자 손실해석)

  • Jang, S.M.;Cho, H.W.;Lee, S.H.;Yang, H.S.;Jeong, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1042-1044
    • /
    • 2003
  • High speed PM machines are being developed as motor/generators for gas-turbine generator sets in smaller power sizes, and as motors for number of applications including gas compressors, machine tools and turbo molecular pumps. Due to the high peripheral speed of the rotor and the relatively high conductivity of the magnets used, rotor eddy current loss can be substantial. This paper deals with the calculation of rotor eddy-current losse in permanent magnet(PM) high speed motor using the analysis of harmonics.

  • PDF

A study on the hierachical optimization methods for the optimal control of nonlinear systems (계층 최적화 기법에 의한 비선형 계통의 최적 제어에 관한 연구)

  • Chun, Hee-Young;Park, Gwi-Tae;Lee, Jong-Ryeol;Lee, Hee-Jeung
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.129-134
    • /
    • 1987
  • In this paper, "Revised two-level costate prediction method" is developed to optimize the quadratic performance of a class of nonlinear dynamic systems. To show the merit, of this algorithm, the proposed algorithm is compared With "The new prediction method" and "Two-level costate prediction method". Advantages of this algorithm are illustrated by applying it to three examples, turbine generator system, fermentation Process, power control system in nuclear reactor.

  • PDF

Modeling and Experiment of LCI system for Gas Turbine Synchronous Generator (가스터빈용 동기발전기를 위한 LCI 시스템 모델링 및 실험)

  • An, Hyunsung;Ryu, Hoseon;Kim, Kyung-seo;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.267-268
    • /
    • 2014
  • 본 논문에서는 LCI (Load Commuted Inverter) 시스템의 구동원리와 제어방식에 대해서 서술하였으며, 알고리즘 검증을 위한 모델링을 매트랩/시뮬링크를 사용하여 진행하였으며, 5kW급 프로토타입을 통해 제어 알고리즘의 성능을 확인하였다. 시스템 속도에 따라 달리하는 구동방식인 강제전류 모드와 자연전류 모드는 동기발전기의 정격속도 10%인 180rpm에서 모드 전환이 이루어지며, 과도상태 및 정격속도까지 안정적인 동작을 확인하였다.

  • PDF

Speed Estimation Method of Turbine and Generator using Variable Frequency type PR controller and Positive-phase-sequence Component Computation in ORC Generation System (ORC 발전 시스템에서 주파수 가변형 PR 제어기와 정상분 추출을 이용한 발전기 속도추정 방법)

  • Park, Hyung-Seok;Heo, Hong-Jun;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.377-378
    • /
    • 2015
  • 본 논문에서는 유기랭킨 사이클(organic rankine cycle: ORC) 발전 시스템에서 터빈과 발전기의 속도를 추정하는 방법을 제안한다. 다이오드 정류기에 의해 왜곡된 발전기 3상 단자 전압은 PLL 기법을 이용한 속도추정의 성능을 저하시키므로, 정상분 추출과 맥동성분 제거를 위한 상태관측기와 주파수 가변형 PR 제어기를 동기좌표계 PLL 기법에 적용하여 발전기의 속도를 추정한다. 제안하는 터빈과 발전기의 속도추정 방법은 실험 결과를 통해 그 성능을 검증한다.

  • PDF