• 제목/요약/키워드: Turbine flowmeter

검색결과 20건 처리시간 0.029초

천연가스 유량계 교정 시스템의 설계${\cdot}$구축 및 운영 (Design, Construction & Operation of Natural Gas Flowmeter Calibration System)

  • 이승준;이강진;정종태;하영철;안승희;이철구;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.389-393
    • /
    • 2001
  • Korea Gas Corporation(KOGAS) have constructed a gas flowmeters' calibration facilities at Jungdong Bucheon. The facilities consisting of 6 reference turbine meters can perform calibrations of large capacity natural gas flowmeters up to $9,600 m^3/h$ at 95 kPa. This large capacity and high pressure natural gas facilities is traceable to the national standard of gas flow rate (KRISS). In this article the motive of construction and description of design are summarized.

  • PDF

소형 푸루버의 유량계 검증 오차 연구 (Study on Flowmeter Proving Errors of a Small Volume Prover)

  • 백종승;임기원;최용문
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.259-266
    • /
    • 1990
  • 본 연구에서는 지금까지 개발된 각종 소형 푸루버의 작동원리 및 장단점을 분 석 비교한 결과에 따라 이중 실린더형의 소형 푸루버를 직접 설계 제작하고, 개발된 소형 푸루버를 사용하여 펄스 주기 변동특성이 각각 다른 유량계를 대상으로 펄스보간 오차 시험을 실시하였다. 실험결과는 통계적 방법을 도입하여 분석함으로써 유량계 각각에 대하여 기대 검증 정확도 수준을 선정하였다. 또 기대검증 정확도가 좋지 않 게 예상되는 유량계에 대해서는 검증 정확도 향상 방안을 제시하였다.

엔진 고공 시험에서 공기 유량 측정용 벤투리 파이프의 제작 및 측정 불확도 분석 (Manufacture and Measurement Uncertainty Analysis of a Venturi Pipe for Airflow Measurement in Altitude Engine Test)

  • 양인영;오중환
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.36-41
    • /
    • 2010
  • Design, manufacture and calibration procedures of a venturi pipe flowmeter for airflow measurement in altitude engine test were discussed. Altitude engine test using venturi pipe was given as an example. The venturi was designed per the ISO standard of ISO5167, and was intented to include the entire airflow range in the test envelope of the gas turbine engine. Measurement uncertainty analysis was performed in the design procedure to investigate the effect of venturi geometry and sensor specification upon the measurement uncertainty. Manufacturing process was designed to minimize the deviation from the geometry of design. Calibration was performed to get the relationship between the discharge coefficient and the pipe Reynolds number. Then the uncertainty was assessed again using real data acquired during engine test. Through these procedures, it was possible to maintain the uncertainty of airflow measurement under 1 % for most of the operating envelope of the gas turbine engine. The discharge coefficient of the venturi pipe showed agreement with the value suggested in the ISO standard ISO5167-4 within 0.6 %.

차압을 이용한 터빈유량계 성능 진단 (Diagnosis on performance of turbine flowmeter using differential pressure in the meter)

  • 하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;김용열;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

소수력 발전설비의 성능시험센터 구축 (Establishing performance test center for a small hydropower)

  • 김영준;김상균;이동근;박주영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.660-663
    • /
    • 2009
  • Currently in Korea, the lack of facilities and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic small hydropower turbine, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore Korean institute of water and environment in K-water planned making a basis of performance test of small hydropower by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system. Improving the efficiency of small hydropower system can achieve the additional development benefit about 1.5 billion won per year.

  • PDF

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.206.2-206.2
    • /
    • 2011
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.

Modeling and Simulation for Level & Flow Control System Using Microcontroller

  • Unhavanich, Sumalee;Dumawipata, Teerasilapa;Tangsrirat, Worapong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.5-86
    • /
    • 2001
  • This work describes a design and implementation of the level & flow rate control system by using a single-chip microcontroller. The proposed model system is designed based on the use of the single-chip microcontroller 8031 with the EPROM emulator for programming the computer software. The microcontroller reaches the input level and flow signals from the level sensor and the turbine flowmeter, respectively, via the signal conditioning circuits and A/D converters in order to calculate the control signal. Moreover, the status of the process variable can easily be set up and controlled by program monitoring through the emulator, and can be graphically displayed on the computer screen. Experiment results were carried out which can be ...

  • PDF

잉여 유출수를 이용한 소수력발전용 수차의 유동특성 해석 및 시험 (Flow characteristics analysis and test in the Pelton turbine for pico hydro power using surplus water)

  • 정선용;이계복
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.325-331
    • /
    • 2016
  • 대형 빌딩에 설치된 냉각탑의 순환수를 이용한 소수력 발전용 수차를 개발하기 위해 펠톤 수차설계를 상용코드인 CFX를 사용한 전산유체 해석을 통해 수행하였다. 소수력 발전용 펠톤 수차의 최적설계를 구하기 위해 파이프 단면에 적합한 형태로 펠톤 휠을 절단한 버킷 모양과 버킷 개수 등 관련 주요 설계 인자를 변화시키며 수차 특성을 해석하여 수차 성능에 대한 영향을 평가하였다. 전산수치 해석에 의한 펠톤 수차설계 방법을 검증하기 위해 축소된 크기의 수차를 제작하고 실험을 통한 벤치마크 시험을 수행하였다. 초음파유량계와 압력 트랜스듀서, 오실로스코프를 사용하여 측정한 유동특성과 출력을 수치해석 결과와 비교하여 수치해석 설계방법의 타당성을 증명하였다. 또한 전산수치 해석을 통해 원하는 출력을 얻기 위한 버킷의 모양과 개수를 선정하여 냉각탑이 설치된 대형빌딩에서 건물 내의 냉각수 순환평균속도는 1.2 m/s이고 빌딩의 높이는 30 m인 경우에 대해 순환하는 냉각수인 잉여수를 이용한 kW급 소수력 발전용 펠톤 수차의 개발 가능성을 확인하였다.