• Title/Summary/Keyword: Tunnel current

Search Result 499, Processing Time 0.035 seconds

Voltage Fluctuation of a Nb/Al-Al$O_{x}$/Nb Tunnel Junction Observed at the Gap Voltage (갭전압에서 나타난 Nb/Al-Al$O_{x}$/Nb 터널 접합의 전압 요동 현상)

  • 홍현권;김규태;박세일;김구현;남두우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.123-126
    • /
    • 2002
  • Samples of Nb/Al-Al$O_{x}$/Nb tunnel junction with the size of 50$\mu$m $\times$ 50$\mu$m were fabricated by employing self-aligning and reactive ion etching technique. In the samples with high-quality, $V_{m}$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density $J_{c}$ = 500 A/$cm^{2}$ and $V_{g}$ value (the gap voltage) was 2.8 mV. In the higher $J_{c}$, voltage fluctuation in the current rising at the gap voltage was observed. The $V_{m}$ and $J_{c}$ value were 8 mV and 900 A/$cm^{2}$, respectively.

  • PDF

The Electrical Conduction Properties of Polyethylene Thin Film for Power Cable with Manufacturing Methods (제작방법에 따른 전력케이블용 폴리에틸렌 박막의 전기전도특성)

  • 조경순;이용우;이수원;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.453-460
    • /
    • 1997
  • In order to investigate the electrical conduction properties of polyethylene thin film for power cable with manufacturing methods, the thickness of specimen was the 30, 100[${\mu}{\textrm}{m}$] of LDPE and 200[${\mu}{\textrm}{m}$] of XLPE were manufactured. The experimental condition for conduction properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and the electric field from 1$\times$10$^3$to 5$\times$10$^{6}$ [V/cm]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high electric field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy. At low electric field, the XLPE showed dominant electrical conduction properties by thermal excitation, and transformation of the electron was resisted by the crystal at high electric field.

  • PDF

Channel Doping Effect at Source-Overlapped Gate Tunnel Field-Effect Transistor (소스 영역으로 오버랩된 TFET의 Channel 도핑 변화 특성)

  • Lee, Ju-Chan;Ahn, Tae-Jun;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.527-528
    • /
    • 2017
  • Current-voltage characteristics of source-overlapped gate tunnel field-effect transistor (SOG-TFET) with different channel doping concentration are proposed. Due to the gaussian doping in which the channel region near the source is highly doped and that far from the source is lightly doped, the ambipolar current was reduced, compared with the uniformly-doped SOG-TFET. On-current is almost similar in P-P-N and P-I-N structure but subthreshold swing (SS) of P-P-N TFET enhanced 5 times higher than those of P-I-N TFET. off-current and ambiploar current of the proposed SOG-TFET decrease 10 times and 100 times than those of the uniformly-doped SOG-TFET.

  • PDF

Mitigation of wind-induced responses of cylinder solar tower by a tiny eddy current tuned mass damper based on elastic wind tunnel tests

  • Liu, Min;Li, Shouying;Chen, Zhengqing
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.619-629
    • /
    • 2020
  • Solar towers, which often has a large aspect ratio and low fundamental natural frequency, were extremely prone to large amplitude of wind-induced vibrations, especially Vortex-Induced Vibration (VIV). A tiny Tuned Mass Damper (TMD) with conveniently adjustable eddy current damping was specially designed and manufactured for elastic wind tunnel tests of a solar tower. A series of numerical simulations by using the COMSOL software were conducted to determine three key parameters, including the thickness of the back iron plate and the conductive plate (Tb and Tc), the distance between the magnet and the conductive plate (Td). Based on the results of numerical simulations, a tiny TMD was manufactured and its structural parameters were experimentally identified. The optimized values of the tiny TMD can be conveniently realized. The tiny TMD was installed at the top of the elastic test model of a 243-meter-high solar tower, and a series of wind tunnel tests were carried out to examine the effectiveness of the TMD in suppressing wind-induced responses of the test model. The results showed that the wind-induced responses could be obviously reduced by the TMD, especially in the cross-wind direction. The cross-wind RMS and peak responses at the critical wind velocity can be reduced by about 86% and 75%, respectively. However, the maximum reduction of the responses at the design wind velocity is about 45%, obviously less than that at the critical wind velocity.

Crosswind effects on high-sided road vehicles with and without movement

  • Wang, Bin;Xu, You-Lin;Zhu, Le-Dong;Li, Yong-Le
    • Wind and Structures
    • /
    • v.18 no.2
    • /
    • pp.155-180
    • /
    • 2014
  • The safety of road vehicles on the ground in crosswind has been investigated for many years. One of the most important fundamentals in the safety analysis is aerodynamic characteristics of a vehicle in crosswind. The most common way to study the aerodynamic characteristics of a vehicle in crosswind is wind tunnel tests to measure the aerodynamic coefficients and/or pressure coefficients of the vehicle. Due to the complexity of wind tunnel test equipment and procedure, the features of flow field around the vehicle are seldom explored in a wind tunnel, particularly for the vehicle moving on the ground. As a complementary to wind tunnel tests, the numerical method using computational fluid dynamics (CFD) can be employed as an effective tool to explore the aerodynamic characteristics of as well as flow features around the vehicle. This study explores crosswind effects on a high-sided lorry on the ground with and without movement through CFD simulations together with wind tunnel tests. Firstly, the aerodynamic forces on a stationary lorry model are measured in a wind tunnel, and the results are compared with the previous measurement results. The CFD with unsteady RANS method is then employed to simulate wind flow around and wind pressures on the stationary lorry. The numerical aerodynamic forces are compared with the wind tunnel test results. Furthermore, the same CFD method is extended to investigate the moving vehicle on the ground in crosswind. The results show that the CFD results match with wind tunnel test results and the current way using aerodynamic coefficients from a stationary vehicle in crosswind is acceptable. The CFD simulation can provide more insights on flow field and pressure distribution which are difficult to be obtained by wind tunnel tests.

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

Crack Detection Method for Tunnel Lining Surfaces using Ternary Classifier

  • Han, Jeong Hoon;Kim, In Soo;Lee, Cheol Hee;Moon, Young Shik
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3797-3822
    • /
    • 2020
  • The inspection of cracks on the surface of tunnel linings is a common method of evaluate the condition of the tunnel. In particular, determining the thickness and shape of a crack is important because it indicates the external forces applied to the tunnel and the current condition of the concrete structure. Recently, several automatic crack detection methods have been proposed to identify cracks using captured tunnel lining images. These methods apply an image-segmentation mechanism with well-annotated datasets. However, generating the ground truths requires many resources, and the small proportion of cracks in the images cause a class-imbalance problem. A weakly annotated dataset is generated to reduce resource consumption and avoid the class-imbalance problem. However, the use of the dataset results in a large number of false positives and requires post-processing for accurate crack detection. To overcome these issues, we propose a crack detection method using a ternary classifier. The proposed method significantly reduces the false positive rate, and the performance (as measured by the F1 score) is improved by 0.33 compared to previous methods. These results demonstrate the effectiveness of the proposed method.

A study on Actual Quantity of Shotcrete Sprayed in a NATM tunnel (NATM 산악터널의 숏크리트 투입율에 관한 연구)

  • Lee, Cheol-Ju;Kim, Sung-Yun;Kim, Dong-Gun;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.57-64
    • /
    • 2009
  • This study has analysed actual overbreak, shotcrete rebound and the ratio between the actual quantity of shotcrete to designed shotcrete measured during a NATM tunnel construction. The measured shotcrete rebound was about 7.2% in average which was about half the allowable rebound (15%), showing shotcrete spraying was performed well. Based on the measurement of excavated tunnel shape, average overbreak was about 28.5cm after tunnel excavation by drill and blasting method. This was about 260% of allowable overbreak. In addition, due to the rebound and overbreak actual amount of shotcrete used in the tunnelling work was about 116.5 % of the designed value. According to the field measurement the ratio of actual shotcrete to designed value showed some relation with standard support pattern, but the size of overbreak did not show the correlation with standard support pattern. Hence current design specifications stating the size of overbreak based entirely on standard support pattern should perhaps be reestablished. The insight into the design guideline regarding overbreak and shotcrete.

  • PDF

A study for application plan of rational residual water pressure on the tunnel linings (터널 라이닝에 작용하는 합리적인 잔류수압 적용방안 검토)

  • Jung, Kuk-Young;Kim, Ji-Yeop;Kim, Ji-Hun;Moon, Hoon-Ki
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.463-499
    • /
    • 2011
  • Control of ground water is one of the most important factors for long-term operation of tunnel because most tunnels are located under the ground water level. In case of a drainage tunnel, there is no pore water pressure on the lining when the drainage system is properly working. After long-term operation, however, residual pore water pressure can be developed on the lining due to the deterioration of the drainage system. In this study, the water pressure distribution under obstruction condition of drainage material and conduit on the tunnel is numerically investigated using the ICFEP program and compared with the current value being applied to the residual water pressure for rational application plan of residual water pressure on the tunnel linings.

Traditional Korean Medicine Therapy for Treating Carpal Tunnel Syndrome in Patients with Wrist Pain: A Systematic Review

  • Kim, Jung Hyun;Song, Ho Sueb
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.59-64
    • /
    • 2015
  • Objectives : This study aims to evaluate current clinical evidence of traditional Korean medicine treatment on wrist pain with carpal tunnel syndrome. Methods : Ten Korean databases were searched for prospective clinical trials of traditional Korean medicine therapy on wrist pain with carpal tunnel syndrome from the time of their inception to February, 2015. Studies conducted in Korean, Chinese and English were searched. Risk of bias in included non-randomized controlled trials was assessed by the Cochrane handbook procedure. Results : Four non-randomized controlled trials were included. A high risk of bias was observed in all trials. All of the included studies reported favorable effects being experienced by an intervention group compared to a baseline or control group. Included studies never described any occurrence of adverse events. Conclusions : There is no evidence that traditional Korean medicine treatments are effective for treating wrist pain associated with carpal tunnel syndrome. All of the included studies lacked appropriate methodological qualities and internal validity. Future well-designed clinical trials that evaluate the effects and safety of traditional Korean medicine treatment for patients with carpal tunnel syndrome are needed.