• Title/Summary/Keyword: Tube-by-Tube

Search Result 7,118, Processing Time 0.04 seconds

Studies on the Development of Acid Tolerant and Superior Nitrogen Fixation Symbionts for Pasture on Hilly Land -III. Inoculation Effect of R. meliloti "YA03" to Alfalfa on Hilly Acid Soil (야산(野山) 목초지용(牧草地用) 내산성(耐酸性) 우수(優秀) 질소고정균주(窒素固定菌株) 개발(開發) -III. 야산(野山) 개간지(開墾地)에서 R. meliloti "YA03"의 알팔파 접종효과)

  • Kang, Ui-Gum;Choi, Ju-Hyeon;Lee, Jae-Saeng;Jung, Yeun-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.3
    • /
    • pp.219-224
    • /
    • 1991
  • An acid tolerant R. meliloti "YA03" which was characterized through both acidified tube and pot soil experiment, was examined on its inoculation effect to alfalfa[Medicago sativa (L.)]cv. Vernal on hilly acid soil. It was conducted for 2 years to evaluate inoculation residual effect and there were two-fertilizer factors of nitrogen(0.8kg/10a) and lime(0,162kg/10a)as urea and $Ca(OH)_2$, respectively. The results obtained were summarized as follows : 1. In the 1st-year experiment, YA03 inoculated without nitrogen and lime application showed higher symbiotic effectiveness than check strains, YA026 and Rm2011 in nodule mass, $N_2$-fixing activity, and dry matter yield, but with N 8kg/10a application lower effectiveness than Rm2011. 2. In the 2nd-year experiment, Alfalfa dry matter yield by YA03 inoculation with N application(without lime) was 74% higher than that(276 kg/10a) in the 1st year, and the value showed 166%, 20%, and 21% increments as compared with noninoculated control(180kg/10a). YA026(399kg/10a), and Rm2011(397kg/10a), respectively. 3. In the 2nd-year experiment of N applicated plote(without lime), especially, YA03 showed higher shoot nitrogen(7.7kg N/10a/Yr.) fixed and soil rhizobial population($1{\times}10^4\;cells/g.\;soil$) than check strains. 4. On the basis of lime application, application effect of three major fertilizers with YA03 inoculation on alfalfa yield and soil rhizobial population was in the order of $N+P_2O_5+K_2O>P_2O_5+K_2O>P_2O_5+K_2O$. 5. On the whole, alfalfa yield by acid tolerant R. meliloti YA03 inoculation on hilly acid soil was enhanced with nitrogen application, and besides it appeared 44% higher with lime than without lime.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Quality and Storage Characteristics of Low Salted Onion and Five Cereals-Doenjang (저염 양파 오곡된장의 품질 및 저장 특성)

  • Shin, A-Ga;Lee, Ye-Kyung;Jung, Yoo-Kyung;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 2008
  • The quality and storage characteristics of low salted onion and five cereals-doenjang (DFO) were investigated. At the DFO, soybean koji ($57{\sim}62%$), onion (3%) and salt (8%) were mixed with equal amount of rice, barley, glutinous millet and glutinous indian millet ($10{\sim}30%$), and water ($7{\sim}12%$). The storage of DFO was done by vacuum packing in polypropylene tube, and sterilized at $121^{\circ}C$. The fermentation and storage was conducted for 60 days at $25^{\circ}C$ at each condition. Control doenjang (GD) was the salinity of 16% soybean doenjang that was not sterilized and packed in plastic containers for storage. During the fermentation, pH of DFO was lower than GD. The pH maintained stability during the storage, and revealed to be lowered, as the proportion of mixed cereals was higher. During the fermentation of DFO, the brix degree revealed to be higher than GD and maintained s1ability during the storage. During the fermentation and storage, the amino nitrogen content of DFO was ranged $400{\sim}470mg%$ by showing higher content than GD and maintained stable content during the storage. During the fermentation, the activities of protease and ${\beta}$-amylase were maintained to be high at DFO, but the activities during the storage were high at GD. The color $L^*$ value of DFO during fermentation and storage maintained higher values than GD, but $a^*$ value revealed lower pattern. Total free amino acids of DFO was ranged $1,918{\sim}2,290mg%$ which was higher than GD that recorded 1,291 mg%. When the sensory evaluation was conducted for DFO that was fermented and stored for 60 days, the DFO mixed with $20{\sim}30%$ of cereals resulted to have more savory taste, flavor, and sweeter than GD, and overall acceptability for color and overall taste was high.

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF

Comparison of a whole blood Interferon-γ assay and A tuberculin skin test for detecting latent tuberculosis infection in children (소아 잠복 결핵 감염 진단에 있어서 투베르쿨린 피부반응 검사와 결핵 특이항원 자극 Interferon-γ 분비능 측정의 비교)

  • Chun, Jin-Kyong;Kim, Chang Ki;Kim, Hyun Sook;Jung, Ghee Young;Linton, John A.;Kim, Ki Hwan;Lee, Taek Jin;Jeon, Ji Hyun;Kim, Dong Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.971-976
    • /
    • 2008
  • Purpose : Surveillance for detecting and managing latent tuberculosis infection (LTBI) is a key component of tuberculosis control. The classic surveillance tool, the tuberculin skin test (TST), may have some limitations when used in the Bacillus Calmette-$Gu{\acute{e}}rin$ (BCG)-vaccinated population. The object was to perform a blood test $QuantiFERON^{(R)}$-TB Gold In Tube (QFT-G IT) based on the detection of interferon-$\gamma$ ($IFN-{\gamma}$) released by T cells in response to Mycobacterium tuberculosis-specific antigens, and to compare the efficacy of this new diagnostic tool for LTBI with that of TST. Methods : For six months, between October 1, 2006 and April 30, 2007, data were collected from 111 patients under 15 years of age at Severance Children's Hospital. TST and QFT-G IT tests were performed with children with or without contact histories of tuberculosis. In addition to these tests, we examined comparative data from 29 adults who had tuberculosis, to detect false negative rates in the QFT-G IT method. Results : Thirty-three children had household contact histories. In this group, 15% and 42% of cases were found to be positive using the QFT-G IT assay and TST, respectively. Agreement was low between these two tests (${\kappa}=0.39$). In the adult active tuberculosis group, the QFT-G IT false negative rate defined as a positive culture and a negative QFT-G IT result was 12.5%. Conclusion : In diagnosing LTBI in children, the usefulness of a whole-blood $IFN-{\gamma}$ assay employing TB-specific antigens will be revealed only by examining additional longitudinal clinical data; this study serves as a starting point in that process.

Bilateral Sequential Lung Transplantation in Dogs (황견에서 동종 순차적 양측 폐이식 수술에 관한 연구)

  • 이두연;김해균;문동석;윤용한;홍윤주;이성수
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.108-112
    • /
    • 1998
  • Experimental trials of unilateral lung transplantation in dogs have been attempted and satisfactory results were obtained without any noticeable difficulty in surgical techniques. Fourteen dogs with the body weight of around 25 kg were anesthesized by 20~30 mg/kg of intravenous Entobar,; one was sacrificed to make available blood for use during transplantation for the recipient dog. A mid-sternotomy incision was performed and 20 mg/kg of Prostaglandin E1 was infused through the pulmonary artery and Euro-Collin's(E-C) preservation solution, cooled down to 4$^{\circ}C$, was perfused at the rate of 70cc/kg by a pressure of 30 cmH2O. The heart-lung block was then resected out and promptly immersed in the prepared preservation solution at 4$^{\circ}C$. One lung preserved in the EC solution at 4$^{\circ}C$ was anastomosed to the recipient dog in the order of the pulmonary vein, bronchus then pulmomary artery and the thoracotomy incision was closed after the bleeding control and tube thoracostomy. Then the pneumonectomy in the opposite side was perfomed in the same manner and the tailored lung was transplanted in the order of the pulmonary vein, bronchus, then pulmonary artery. We conclude that in the bilateral sequential lung transplantation, the right lung transplantation should precede to better expose the operative field and to prevent reperfusion injury; also, the cardiopulmonary bypass should be consider for certain appropriate cases.

  • PDF

Characteristics and Virulence Assay of Entomopathogenic Fungus Nomuraea rileyi for the Microbial Control of Spodoptera exigua (Lepidoptera: Noctuidae) (파밤나방의 미생물적 방제를 위한 병원성 곰팡이 Nomuraea rileyi의 특성 및 병원성 검정)

  • Lee, Won Woo;Shin, Tae Young;Ko, Seung Hyun;Choi, Jae Bang;Bae, Sung Min;Woo, Soo Dong
    • Korean Journal of Microbiology
    • /
    • v.48 no.4
    • /
    • pp.284-292
    • /
    • 2012
  • To date, chemical control remains the most common way to reduce beet armyworm (Spodoptera exigua) populations. However, this insect has become more tolerant or resistant to many chemical insecticides and the insect larvae usually hide inside hollow, tube-like leaves of host plant so they were difficult to kill by spraying insecticides. The use of viral and bacterial insecticide to solve these problems has not been successful because of their novel feeding habit. To overcome these problems, in this study, the biological characteristics and virulence of an entomopathogenic fungus isolated from the cadaver of larvae beet armyworm were investigated. Isolated entomopathogenic fungus was identified as Nomeraea rileyi (Farlow) Samson by morphological examinations and genetic identification using sequences of the ITS, ${\beta}$-tubulin gene and EF1-${\alpha}$ regions. This fungus was named as N. rileyi SDSe. Virulence tests against 3rd larvae of beet armyworm were conducted with various conidial suspensions from $1{\times}10^4$ to $10^8$ conidia/ml of N. rileyi SDSe in laboratory conditions. Mortality rate of beet armyworm showed from 20 to 54% and the virulence increased with increasing conidial concentrations. Although N. rileyi SDSe showed low mortality rate against beet armyworm, it is expected that N. rileyi SDSe will be used effectively in the integrated pest management programs against the beet armyworm.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

Staged Fontan Operation Via Bidirectional Glenn Operation (양방향성 GLENN 수술을 통한 단계적 FONTAN 수술의 임상분석)

  • 한재진;김웅한
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1062-1068
    • /
    • 1997
  • From August 1989 to January 1996, a total of 105 cases of bidirectional Glean operations have been done as the interim stage for the patien s with some risk of univentricular correction at Sejong General Hospital. From December 1992, we started the conversion to Fontal operations for them, and 42 cases underwent Fontal-stage operation till February 1996. Their diagnoses were univentricular heart in 19(right ventricular type : 14), tricuspid atresia 11, double outlet of right ventricle 9, and others in 3 cases. The median age of bidirectional Glerln-stage operation was 12.5 months(range 2 months to 8 years) and Fontan-stage operation was at 59.6 months of median age(range 1 year 5 months to ,9 year 7 months). The mean waiting interval between the two operations was 33.88 $\pm$ 17.85 months with a range of 10 months to 6 years 3 months. During the waiting periods, 18 patients developed significant systemic-pulmonary collaterals andfor systemic verso-veno collateral channels. There were 5 hospital deaths after operations due to low cardiac output in 4 and sepsis in one. Most of the Fontal-stage operations were done by the late al tunneling with Core-Tex tube graft patch and fenestrated with the size of 2.5 ~6 mm. All the patients were followed-up(7 months to 4 years 2 months, mean 21.97$\pm$10.82 months) and there were 5 late deaths(postoperatively 6 months to 2 years) due to thromboembolism in 1, after heart transplantation 1, plastic bronchitis 1, protein loosing enteropathy 1, and pneumonia in 1. Dividing the patients by the waiting interval of 2 years, the early correction to Fontal group (N=16) showed the better results(hospital mortality 1116, late mortality 1116, significant collateral development 2/16) compared to the other group(N=26) (4/26, 4/26, 16/26). In conclusion, after the bidirectional Glean-stage operation successfully got rid of the previous risk factors, we recommand to do the Fontan-stage operation no later than 2 years of interval.

  • PDF

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF