• Title/Summary/Keyword: Tube Voltage

Search Result 597, Processing Time 0.026 seconds

Electric Field Simulation and Characteristics of Water Treatment Apparatus using Dielectrics (유전체를 이용한 수처리장치의 전계시뮬레이션 및 수처리 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.333-335
    • /
    • 2005
  • The simulation of electric field distribution of discharge tube with globular $ZrO_2$ and the removal characteristic of Escherichia coli by the discharge tube with globular $ZrO_2$ were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the particle size of $ZrO_2$ beads increased, the removal time of Escherichia coli was shortened due to the dielectric polarization of $ZrO_2$ beads.

  • PDF

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

Experimental Study on the Enhancement of Condensation Heat Transfer on a Single Horizontal Tube Utilizing EHD (전장을 이용한 수평관 주위에서의 응축 열전달촉진에 관한 실험적 연구)

  • 유갑종;추홍록;김석준;이성진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3008-3020
    • /
    • 1994
  • Condensation heat transfer on a single horizontal tube with electric fields (Electro-Hydro-Dynamics, (EHD)) has been studied experimentally. Results are presented for EHD enhanced condensation of R-113 on a single horizontal tube using several electrode geometries. Especially, its attention was focused on the effects of electrode geometry, electric field strength and the gap of the electrode. In this study, single wire, helical, ring and mesh electrode were used. The range of the imposed voltage was 0~20 kV. As the voltage was increased the surface of liquid became an unstable wave, stream jet, liquid column and then liquid extraction in sequence. Among the various kinds of electrodes, the single wire electrode is suitable for practical application.

A study on Harmful Bacillus Detection used discharge in water (수중 방전을 이용한 유해 세균 검출 분석 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Cho, Moon-Soo;Park, Bo-Hyun;Shin, Kwang-Chul;Lee, Dong-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.285-289
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads$(SiO_2,\;Al_2O_3,\;or\;ZrO_2)$ for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric $bead(ZrO_2)$, the removal characteristics of Escherichia coli was better than cases of else.

  • PDF

A study on Harmful Bacillus Removal Analysis (유해 세균 제거 분석 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Cho, Moon-Soo;Park, Bo-Hyun;Shin, Kwang-Chul;Lee, Dong-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.38-42
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads($SiO_2$, $Al_2O_3$, or $ZrO_2$), and discharge in water for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric bead($ZrO_2$), the removal characteristics of Escherichia coli was better than cases of else.

  • PDF

Study on the High Tension on Radiography and Density of Barium Sulphate (관전압(管電壓)과 황산(黃酸)바륨의 농도(濃度)에 관(關)한 연구(硏究))

  • Kyong, Kwang-Hyon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 1980
  • An experimental study was carried out to make a comparison between tube voltage and density of barium sulphate in the stomach radiography. The results were summarized as follows: 1. The percentage of density on concentrations of barium sulphate as contrast media could not show in differences with changes of voltages applied X-ray tube. 2. The changes of density visualized on X-ray film mainly depend upon with thickness of stomach filled barium sulphate than the ratio of barium sulphite and plain water volume. 3. The lesions positioned in upper part within stomach exhibited their best discrimination performanance with depth in the low tube voltage, followed in order by the middle part and lower part. However, the discrimination performanance at the high tension radiography uniformly visualized over X-ray film without density in change.

  • PDF

Correction Factor for the Eenergy Dependence of a Optically Stimulated Luminescent Dosimeter in Diagnostic Radiography (진단방사선촬영에서 광자극형광선량계의 에너지의존성에 대한 보정인자)

  • Kim, Jong-Eon;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.261-265
    • /
    • 2011
  • The purpose of this study is to calculate correction factors for energy dependence of a nanoDotdosimeter to measure patient's skin dose in diagnostic radiography. The correction factors were calculated by using the values of mean energy for the RQR standard radiation qualities of IEC publicated by Rosado et al. and the energy response graph of dosimeter relative X-ray on phantom calibration provided by landaur corporation. Results showed the correction factors of 1-1.33 over the tube voltage range of 40-50 kVp. Acquired correction factors are considered to be useful in the clinics for the measurement of accurate skin dose at each tube voltage.

An experimental study for boiling heat transfer enhancement under electric fields (전기장하에서의 비등 열전달 촉진에 관한 실험적 연구)

  • O, Si-Deok;Gwak, Ho-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2298-2314
    • /
    • 1996
  • Electric field effect on boiling of refrigerants R11, R113, and FC72 has been investigated experimentally. One purpose of the experimental investigation is to determine the effects of the electrode arrangements on electrohydrodynamic boiling of the above mentioned liquids. The test equipment employed in the experiment consists of a shell and tube heat exchanger with six or six and twelve rows of electrode wires around the tube. It has been found that the applied voltage promotes the boiling heat transfer coefficient except FC72. Boiling heat transfer enhancement obtained is about 230% for R11, 280% for R113. It has also been observed that bubbles detached from the tube aggregate at the place where the electrical gradient force balances with the buoyancy one. These aggregated bubbles force to decrease the boiling heat transfer coefficient as well as to reduce the voltage needed to the dielectric breakdown.

The Electrical Breakdown Characterization of Gas Discharge Tube using Brass Electrode for Surge Protector (과전압 보호용 황동전극 기체방전관의 절연파괴 특성)

  • Kim, Min Il;Jeong, Euigyung;Lee, Sei-Hyun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.205-210
    • /
    • 2010
  • In this study, a brass electrode gas discharge tube (GDT) was prepared to investigate its discharge characterization, which affects surge protection efficiency and lifetime of GDT. Discharge characterization of GDT using a brass electrode was investigated by changing applied voltage gradient and nitrogen gas pressure inside the GDT. As applied voltage gradient in GDT increased, electrical breakdown voltage and threshold energy largely increased and electrical breakdown time delay decreased. It was found that electrical breakdown voltage, electrical breakdown time delay, and threshold energy were largely decreased with decreasing the nitrogen gas pressure in GDT. As a result, electrical breakdown voltage, electrical breakdown time delay, threshold energy needed to be decreased to increase surge protection efficiency and lifetime. It was also found that the nitrogen gas pressure of GDT influenced strongly the performances as well as life span of it.

A Characteristics on Water Quality Analysis Used the High-Voltage Discharge (고전압 방전을 이용한 수질분식에 관한 특성)

  • Cho, Kook-Hee;Kim, Young-Bae;Cho, Moon-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.156-161
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads(SiO$_2$, $Al_2$O$_3$, or ZrO$_2$), and discharge in water at High-voltage pulse$.$DC power supply for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric bead(ZrO$_2$), the removal characteristics of Escherichia coli was better than cases of else. And discharge used DC Power, the removal characteristics of Escherichia coli was better than AC Pulse Power.