• Title/Summary/Keyword: True coincidence

Search Result 11, Processing Time 0.026 seconds

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Uranium Enrichment Determination Using a New Analysis Code for the U XKα Region: HyperGam-U

  • Kim, Junhyuck;Choi, Hee-Dong;Park, Jongho
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.778-784
    • /
    • 2016
  • HyperGam-U was recently developed to determine uranium enrichment based on ${\gamma}$- and X-ray spectroscopy analysis. The $XK_{\alpha}$ region of the uranium spectrum contains 13 peaks for $^{235}U$ and $^{238}U$ and is used mainly for analysis. To describe the X-ray peaks, a Lorentzian broadened shape function was used, and methods were developed to reduce the number of fitting parameters for decomposing the strongly overlapping peaks using channel-energy, energy-width, and energy-efficiency calibration functions. For validation, eight certified reference material uranium samples covering uranium enrichments from 1% to 99% were measured using a high-resolution planar high-purity germanium detector and analyzed using the HyperGam-U code. When corrections for the attenuation and true coincidence summing were performed for the detection geometry in this experiment, the goodness of fit was improved by a few percent. The enrichment bias in this study did not exceed 2% compared with the certified values for all measured samples.

Positron Emission Computed Tomographs and Image Reconstruction Methods (PET 장치와 화상 재구성법)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • This paper reviews recent major activities on instrumentation and methodology of PET. The performance of the PET instrumentation can be expressed by four physical characteristics, 1) spatial resolution, 2) coincidence resolving time, 3) energy resolution, and 4) detection efficiency. The physical and technical aspects of PET systems are briefly discussed along with these characteristics. Toward high resolution PET the recent trend has been to design multiple rings of densely packed detector arrays with scintillators. In order to satisfy the sampling requirement in reconstruction, continuous detector units has been developed. Iterative image reconstruction algorithms have received considerable attention for improvement of both the sampling requirement and image quality toward the stationary PET. Better resolving time improves the maximum true coincidence rate, which is also increased with more detectors placed in coincidence with each other. It suggests that volume PET is promising for enhancement of detection efficiency. The scattered coincidence event rate may be reduced by using detectors with better energy resolution. The use of interplane septa, however, takes over improvement of energy resolution in 2D PET. Energy resolution becomes an important factor for image quality under the condition of septa removal such as volume PET. Toward full utilization of emitting photons, 3D reconstruction incorporating oblique rays has been studied, and volume reconstruction algorithms have been developed. Practical volume PET systems impose heavy burden not only to detector sets and coincidence circuits, but also to computers in the memory requirements and the data processing. In conclusion, there have been many ingenious methods in development of PET instrumentation, which are based on unique capability of PET. They will be expected to overcome technical limitations, and to approach the fundamental limits.

  • PDF

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer (비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할)

  • Lee, Sun-Min;Choi, Young-Hwa;Oh, Yoon-Jung;Cheong, Seong-Cheoll;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong;Park, Chan-H;Hahn, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.642-649
    • /
    • 1999
  • Background: It is very important to determine an accurate staging of the non-small cell lung cancer(NSCLC) for an assessment of operability and it's prognosis. However, it is difficult to evaluate tumor involvement of mediastinal lymph nodes accurately utilizing noninvasive imaging modalities. PET is one of the sensitive and specific imaging modality. Unfortunately PET is limited use because of prohibitive cost involved with it's operation. Recently hybrid SPECT/PET(single photon emission computed tomography/positron emission tomography) camera based PET imaging was introduced with relatively low cost. We evaluated the usefulness of coincidence detection(CoDe) PET in the detection of metastasis to the mediastinal lymph nodes in patients with NSCLC. Methods: Twenty one patients with NSCLC were evaluated by CT or MRI and they were considered operable. CoDe PET was performed in all 21 patients prior to surgery. Tomographic slices of axial, coronal and sagittal planes were visually analysed. At surgery, mediastinal lymph nodes were removed and histological diagnosis was performed. CoDe PET findings were correlated with histological findings. Results: Twenty of 21 primary tumor masses were detected by the CoDe PET. Thirteen of 21 patients was correctly diagnosed mediastinal lymph node metastasis by the CoDe PET. Pathological N0 was 14 cases and the specificity of N0 of CoDe PET was 64.3%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N1 node was 83.3%, 73.3%, 55.6%, 91.7%, and 76.2% respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N2 node was 60.0%, 87.5%, 60.0%,87.5%, and 90.0% respectively. There were 3 false negative cases but the size of the 3 nodes were less than 1cm. The size of true positive nodes were 1.1cm, 1.0cm, 0.5cm respectively. There were 1 false positive among the 12 lymph nodes which were larger than 1cm. False positive cases consisted of 1 tuberculosis case, 1 pneumoconiosis case and 1 anthracosis case. Conclusion: CoDe PET has relatively high negative predictive value in the enlarged lymph node in staging of mediastinal nodes in patients with NSCLC. Therefore CoDe PET is useful in ruling out metastasis of enlarged N3 nodes. However, further study is needed including more number of patients in the future.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A Study on the Narratives of Lee Ae-rim's Comic Books -Focusing on the Characteristics of Repetition, Coincidence, and Fantasy (이애림 만화 서사 연구 -반복, 우연, 환상의 특성을 중심으로)

  • Lee, Cheong
    • Journal of Popular Narrative
    • /
    • v.25 no.1
    • /
    • pp.281-313
    • /
    • 2019
  • This paper was written to investigate the narrative traits of Lee Ae-rim's Comic Books. Lee Ae-rim arrived on the scene with the boom of comic book magazines in the 1990s. Although she started her career as a Comic Book writer, she expanded her own area gradually and has been working actively as an animation director as well. The superficial characteristics of Lee Ae-rim's works can be summed up as sexuality, grotesqueness, and fantasy. In other words, Lee Ae-rim's comic books are mainly characterized by the visualization of sexual, grotesque, and fantastic shapes. Lee Ae-rim has faced challenges with her own overwhelming and compelling images like no one else. For that reason, it is true that people haven't paid careful attention to the hidden stories behind her pictures. This paper considers that looking back on the narratives that Lee Ae-rim has been interested in, from early days to recent days, that is to say, the contexts of stories, is a shortcut to reveal a point of contact between her past, present, and future. Especially, this paper focused on the properties of the circulated and repeated stories, the stories ruled by fate and coincidence, and the stories in which elements of fantasy encounter an attempt of violation. As a result, it was found that the narratives of Lee Ae-rim's comic books demand us to face suppressed desires in a new way, by wrapping up the most fundamental aspects of human being in universality and constancy with specificity and grotesqueness. The reason why Lee Ae-rim has continued the avant-garde and omnidirectional works thus far explains what our society suppresses, inversely. Moreover, the narratives of Lee Ae-rim are significant, by being devoted to the right function of art not only to disclose suppressed desires but to satisfy them. Making an in-depth investigation of the narratives of Lee Ae-rim's comic books in various contexts, this research is intended to establish a diversity of Korean comic books, by adding meaning to the creative values of individual writers.

A Study on Hybrid Expressed in Modern Fashion - Focusing on the End of 1990s - (현대패션에 표현된 하이브리드 경향 연구 - 1990년대 후반을 중심으로 -)

  • 임영자;한윤숙
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.5
    • /
    • pp.113-134
    • /
    • 2001
  • This study was carried out with an objective to prepare the framework of conformity for the 21st century modern fashion, which is interactive with mankind, based on a position that the 21st century contemporary fashion with its amalgamating trend of diversified artistic forms may not be elucidated on a standpoint centering on one certain modality. The hybrid fashion trend of historical modality which provides freedom and satisfaction in creation of an individuals expressive power in expressing true desire of mans inside through man-centered thought of the times has made multifarious motives of the past and present fragmentary. It thus extracts inner divisions and the concept of consolidation through three-dimensional form. Modern fashion is newly interpreted by the material and details of high technologies. and is harmonized by mix and match with various expressions. By having it, it is being expressed together with many types of dresses and ornaments. Modern fashion is being expressed together with many types of dresses and ornaments by new interpretations with the material and details of high technologies and by being harmonized with mix and match with various expressions. The hybrid fashion design trend of regional elements formed by stimuli and contacts of diverse local culture by globalization of network that was achieved by scientific technologies of the contemporary information society has disintegrated varied boundaries in the conventional culture by the latest communication technology-new media on the basis of newly created culture. The fact that regional elements could be expressed as if they were interrelated without each being deprived of originality may be explained with an interpretation on pluralism. The hybrid fashion design trend of cultural aspect, which manifests in the background of scientific technological culture as it transcends the societal-cultural boundaries based on the de-centralization theory of Frederic Jameson, has supplemented the imperfect meanings through conversional correlation with other forms and internal program changes. The middle stratal and polyhedral characteristics are seen as each cultural element is dismantled and reassembled by application of 'multiple-time point expression'. Design forming method is not to bring destruction from outside, but to embrace instability and chaos through radical dismantling of the inside. and to pursue diversity and openness. Thus. it is implemented by an approach that takes the role of design process. In communication of discontinuity, continuity was dismantled through forms of mixing, overlap, perversion, insertion and coincidence.

  • PDF