• Title/Summary/Keyword: Triple Beam

Search Result 33, Processing Time 0.025 seconds

A study on the Framed Structure with Triple Beam In the Korean Wooden Architecture (한국 목조건축의 삼중량(三重樑) 가구(架構)에 관한 연구)

  • Yang, Jae-Young
    • Journal of architectural history
    • /
    • v.17 no.3
    • /
    • pp.61-80
    • /
    • 2008
  • The purpose of this study is to discover the characteristics and the change of the framed structure with triple beam. 61 existing buildings with the triple beam structure were selected and analyzed extensively. The result of this study could be described in detail like below. The triple beam structure is used in the highly graded and symbolized building like the Buddhist sanctum and the Confucian sanctum. And the triple beam structure was chiefly used in $1600{\sim}1800's$. Generally, 1 Koju-type with Toikan(退間) is applied to the triple beam structure. Despite of the sameness of framed structure, there is a tendency that the rear Toikan(後退間) is used in the Buddhist sanctum and the front Toikan(前退間) is used in the Confucian sanctum. This different application of the Toikan(退間) resulted from the different spatial characteristics which reflect function and grade of the building. The application of Sangjungdori(上中道里, upper purlin) and two Danyeon(短椽, short rafter) is a necessary consequence, because Jungbo(중보, middle beam) is located between Daebo(대보, beam) and Jongbo(종보, small and high located beam) as an additional member of frame. And these are essential characteristics of the framed structure with triple beam. The triple beam structure is formed in a transitional period, as the result from eliminating the inner high-column from the 2 Koju and double beam structure. Though the Daebo is longer, the structure is more stable. But the rate of application of the triple beam structure is low, because it does not exceed the double beam structure in merits. Some of buildings with the triple beam structure has the asymmetrical characteristic in design, which is appeared in the latter period of Joseon Dynasty.

  • PDF

Commissioning of neutron triple-axis spectrometers at HANARO

  • Hiraka, Haruhiro;Lee, Jisung;Jeon, Byoungil;Seong, Baek-Seok;Cho, Sangjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2138-2150
    • /
    • 2020
  • We report the status of the cold neutron triple-axis spectrometer (Cold TAS) and thermal neutron triple-axis spectrometer (Thermal TAS) installed at HANARO. Cold TAS, whose specifications are standard across the world, is in the final phase of commissioning. Proper instrument operation was confirmed through a feasibility study of phonon measurements and data analyses with resolution convolution. In contrast, Thermal TAS is in the initial phase of commissioning, and improvement of the monochromator drum is now in progress from the viewpoint of radiation shielding. In addition, we report recent activities in the development of neutron basic elements, that is, film-coated Si-wafer collimators, which are promising for use in triple-axis spectroscopy, particularly in Cold TAS.

A Study of 0.5-bit Resolution for True-Time Delay of Phased-Array Antenna System

  • Cha, Junwoo;Park, Youngcheol
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.96-103
    • /
    • 2022
  • This paper presents the analysis of increasing the resolution of True-Time-Delay (TTD) by 0.5-bit for phased-array antenna system which is one of the Multiple-Input and Multiple Output (MIMO) technologies. For the analysis, a 5.5-bit True-Time Delay (TTD) integrated circuit is designed and analyzed in terms of beam steering performance. In order to increase the number of effective bits, the designed 5.5-bit TTD uses Single Pole Triple Throw (SP3T) and Double Pole Triple Throw (DP3T) switches, and this method can minimize the circuit area by inserting the minimum time delay of 0.5-bit. Furthermore, the circuit mostly maintains the performance of the circuit with the fully added bits. The idea of adding 0.5-bit is verified by analyzing the relation between the number of bits and array elements. The 5.5-bit TTD is designed using 0.18 ㎛ RF CMOS process and the estimated size of the designed circuit excluding the pad is 0.57×1.53 mm2. In contrast to the conventional phase shifter which has distortion of scanning angle known as beam squint phenomenon, the proposed TTD circuit has constant time delays for all states across a wide frequency range of 4 - 20 GHz with minimized power consumption. The minimum time delay is designed to have 1.1 ps and 2.2 ps for the 0.5-bit option and the normal 1-bit option, respectively. A simulation for beam patterns where the 10 phased-array antenna is assumed at 10 GHz confirms that the 0.5-bit concept suppresses the pointing error and the relative power error by up to 1.5 degrees and 80 mW, respectively, compared to the conventional 5-bit TTD circuit.

Theoretical analysis of chirality and scale effects on critical buckling load of zigzag triple walled carbon nanotubes under axial compression embedded in polymeric matrix

  • Bensattalah, Tayeb;Zidour, Mohamed;Daouadji, Tahar Hassaine;Bouakaz, Khaled
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.269-277
    • /
    • 2019
  • Using the non-local elasticity theory, Timoshenko beam model is developed to study the non- local buckling of Triple-walled carbon nanotubes (TWCNTs) embedded in an elastic medium under axial compression. The chirality and small scale effects are considered. The effects of the surrounding elastic medium based on a Winkler model and van der Waals' (vdW) forces between the inner and middle, also between the middle and outer nanotubes are taken into account. Considering the small-scale effects, the governing equilibrium equations are derived and the critical buckling loads under axial compression are obtained. The results show that the critical buckling load can be overestimated by the local beam model if the small-scale effect is overlooked for long nanotubes. In addition, significant dependence of the critical buckling loads on the chirality of zigzag carbon nanotube is confirmed. Furthermore, in order to estimate the impact of elastic medium on the non-local critical buckling load of TWCNTs under axial compression, the use of these findings are important in mechanical design considerations, improve and reinforcement of devices that use carbon nanotubes.

Painful Boney Metastases

  • Smith, Howard S.;Mohsin, Intikhab
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.223-241
    • /
    • 2013
  • Boney metastasis may lead to terrible suffering from debilitating pain. The most likely malignancies that spread to bone are prostate, breast, and lung. Painful osseous metastases are typically associated with multiple episodes of breakthrough pain which may occur with activities of daily living, weight bearing, lifting, coughing, and sneezing. Almost half of these breakthrough pain episodes are rapid in onset and short in duration and 44% of episodes are unpredictable. Treatment strategies include: analgesic approaches with "triple opioid therapy", bisphosphonates, chemotherapeutic agents, hormonal therapy, interventional and surgical approaches, steroids, radiation (external beam radiation, radiopharmaceuticals), ablative techniques (radiofrequency ablation, cryoablation), and intrathecal analgesics.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Flexural Strength of RC Beam Strengthened by Partially De-bonded Near Surface-Mounted FRP Strip

  • Seo, Soo-yeon;Choi, Ki-bong;Kwon, Young-sun;Lee, Kang-seok
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.149-161
    • /
    • 2016
  • This paper presents an experimental work to study the flexural strength of reinforced concrete (RC) beams strengthened by partially de-bonded near surface-mounted (NSM) fiber reinforced polymer (FRP) strip with various de-bonded length. Especially, considering high anchorage capacity at end of a FRP strip, the effect of de-bonded region at a central part was investigated. In order to check the improvement of strength or deformation capacity when the bonded surface area only increased without changing the FRP area, single and triple lines of FRP were planned. In addition, the flexural strength of the RC member strengthened by a partially de-bonded NSM FRP strip was evaluated by using the existing researchers' strength equation to predict the flexural strength after retrofit. From the study, it was found that where de-bonded region exists in the central part of a flexural member, the deformation capacity of the member is expected to be improved, because FRP strain is not to be concentrated on the center but to be extended uniformly in the de-bonded region. Where NSM FRP strips are distributed in triple lines, a relatively high strength can be exerted due to the increase of bond strength in the anchorage.

An Effective Quasi-static Modeling of the Piezoelectric Benders (압전 벤더의 효과적인 모델링 기법)

  • Park, Jong-Kyu;Moon, Won-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.133-142
    • /
    • 2004
  • In this article, the constitutive relations of three types of piezoelectric benders, which are a unimorph bender, a bimorph bender and a triple-layer bender, are derived based on the beam theory under the quasi-static equilibrium condition. The relation coefficients are described as the geometry and material properties of the benders. More general constitutive relations involving fixed-free, fixed-roll, and fixed-simply supported boundary conditions under the inconsistent length condition between the piezoelectric layer and the nonpiezoelectric one are discussed. The complicated constitutive relations can be easily calculated and checked by using the symbolic function in ‘Mathematica’. The relation coefficients for the benders are plotted in three dimensional graph using the developed program.

A Study of World Map Building for Mobile Robot with Tri-Acral Ultrasonic Sensor System (세 개의 초음파 센서를 사용한 이동 로보트용 월드 맵 구성에 관한 연구)

  • 전형조;김병국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.6
    • /
    • pp.840-848
    • /
    • 1995
  • A new tri-aural ultrasonic sensor system is suggested to build more accurate world maps for mobile robots with less scanning. In ordinary single sensor systems, the inherent beam-width of sonar transmitter causes ambiguity in sensing direction. Dual sensors may be used to discriminate plane and corner with several scans. However, the proposed method uses triple sensors, and achieves more accuracy with less scanning.

  • PDF

The Fast Intelligent Tracking (F!T) Tube: Feedback Signal Acquisition

  • Lieshout, P.J.G. van;Engelaar, P.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.351-354
    • /
    • 2002
  • The F!T tube is a new type of CRT without a shadow mask. Correct color reproduction is performed by an electronic system that measures the landing positions of the electron beams and corrects through a dedicated deflection system. This paper describes in detail the position sensor and some of the electronics needed to build a functional control system. The principle has been shown in single- and triple-beam 17" and 32" tubes, of which results are included.

  • PDF