• Title/Summary/Keyword: Trigger generator system

Search Result 14, Processing Time 0.036 seconds

A study on the design of triggering pulse generator for the triggered vacuum switch (진공스위치 트리거 발생기 설계에 관한연구)

  • Kim, Mu-Sang;Son, Yun-Gyu;Park, Ung-Hwa;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

Development of the Spark-gap Switch with Dual Trigger System (쌍방향 시동방식의 고속투입스위치 개발)

  • Kim, Maeng-Hyeon;Seo, Yun-Taek;Park, Seung-Jae;Park, Byeong-Rak;Go, Ui-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Agent based real-time fault diagnosis simulation (에이젼트기반 실시간 고장진단 시뮬레이션기법)

  • 배용환;이석희;배태용;이형국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.670-675
    • /
    • 1994
  • Yhis paper describes a fault diagnosis simulation of the Real-Time Multiple Fault Dignosis System (RTMFDS) for forcasting faults in a system and deciding current machine state from signal information. Comparing with other diagnosis system for single fault,the system developed deals with multiple fault diagnosis,comprising two main parts. One is a remotesignal generating and transimission terminal and the other is a host system for fault diagnosis. Signal generator generate the random fault signal and the image information, and send this information to host. Host consists of various modules and agents such as Signal Processing Module(SPM) for sinal preprocessing, Performence Monotoring Module(PMM) for subsystem performance monitoring, Trigger Module(TM) for multi-triggering subsystem fault diagnosis, Subsystem Fault Diagnosis Agent(SFDA) for receiving trigger signal, formulating subsystem fault D\ulcornerB and initiating diagnosis, Fault Diagnosis Module(FDM) for simulating component fault with Hierarchical Artificial Neural Network (HANN), numerical models and Hofield network,Result Agent(RA) for receiving simulation result and sending to Treatment solver and Graphic Agent(GA). Each agent represents a separate process in UNIX operating system, information exchange and cooperation between agents was doen by IPC(Inter Process Communication : message queue, semaphore, signal, pipe). Numerical models are used to deseribe structure, function and behavior of total system, subsystems and their components. Hierarchical data structure for diagnosing the fault system is implemented by HANN. Signal generation and transmittion was performed on PC. As a host, SUN workstation with X-Windows(Motif)is used for graphic representation.

  • PDF

Active Network Management System with Automatic Generation of Network Management Program using Triggers (트리거를 이용한 네트워크관리프로그램 자동생성 기능을 가진 능동적인 네트워크 관리 시스템)

  • Shin, Moon-Sun;Lee, Myong-Jin
    • Journal of Internet Computing and Services
    • /
    • v.10 no.1
    • /
    • pp.19-31
    • /
    • 2009
  • Network management involves configuring and operating various network elements in a suitable manner. Generally, a network management system can perform basic functionalities such as configuration management, performance management, and fault management. Due to the open structure of the Internet, the volume of network traffic and the network equipment used have increased in size and complexity. Therefore, it is expensive and time consuming to develop a network management program for heterogeneous network equipment in an SNMP.based network. In order to facilitate the management of network environments and the control of heterogeneous devices in an efficient manner, we propose an Active Network Management System (ANMS) comprising an automatic generator that uses triggers to generate a network management program. The concept of triggers can be represented through event condition action rules performed in response to a change in the status of a network environment. The proposed ANMS comprises basic components for real time network management and also includes an automatic generator (AG). When the ANMS is monitoring network elements that are newly added or changed, a trigger rule is activated and these components are then able to collaborate and automatically generate a new network management program by using the information provided along with the SNMP libraries. Our method is useful for expanding the network structure and replacing network equipment. Through experiments, we have proved that our ANMS is useful when new network objects are added or changed in the network environment to expand the network structure. Further, we have verified that our ANMS system reduces the time and cost required to develop a network management program as compared to the manual method used in existing network management systems.

  • PDF

A Study on the NDT System U sing Piezoelectric Transducers (압전트랜스듀서를 이용한 비파괴검사장치에 관한 연구)

  • Hwang, Hyun-Suk;Song, Joon-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1594-1596
    • /
    • 1996
  • The NDT(nondestructive test) using pulse echo method with piezoelectric transducers and the system for NDT including image processing were studoed. The system consisted of pulse generator and receiver, two step motors for X-Y scanner, PC-Scope for data aquisition and PC-Lab for trigger and motor driving. We tested and estimated at one point under the following conditions : 1) just water, 2) Aluminum without any crack and 3) Aluminum with hole. The estimated NDT result of whole area (point : $35{\times}20$) is compared with real samples.

  • PDF

The Study on the Characteristics and Design Method of High-Tc Superconducting Persistent Current Switch (고온초전도 영구전류스위치의 특성 및 설계에 관한 연구)

  • 박상건;강형구;배덕권;윤용수;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.216-219
    • /
    • 2003
  • Persistent Current Switch (PCS) is used in many superconducting magnet system. To apply the high-Tc superconductor in superconducting machine such as motor, generator, MAGLEV, MRI and NMR, the study on the persistent current mode should be performed. Because persistent current mode provide best stability and homogeneous characteristics to the superconducting machine. To stabilize the superconductor system, it is important to estimate the length of PCS. If the proper length of PCS is too short, it cause serious injury to system in fault state. So we calculated the optimal length of PCS in this paper.

  • PDF

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

A Method of Fault Diagnosis for Engine Synchronization Using Analytical Redundancy (해석적 중복을 이용한 내연 기관 엔진의 동기화 처리 이상 진단)

  • 김용민;서진호;박재홍;윤형진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.89-95
    • /
    • 2003
  • We consider a problem of application of analytical redundancy to engine synchronization process of spark ignition engines, which is critical to timing for every ECU process including ignition and injection. The engine synchronization process we consider here is performed using the pulse signal obtained by the revolution of crankshaft trigger wheel (CTW) coupled to crank shaft. We propose a discrete-time linear model for the signal, for which we construct FDI (Fault Detection & Isolation) system consisting residual generator and threshold based on linear observer.

An Adaptive Received Signal Strength Prediction Model for a Layer 2 Trigger Generator in a WLAM System (무선 LAN 시스템에서 계층 2 트리거 발생기 설계를 위한 적응성 있는 수신 신호 강도 예측 모델)

  • Park, Jae-Sung;Lim, Yu-Jin;Kim, Beom-Joon
    • The KIPS Transactions:PartC
    • /
    • v.14C no.3 s.113
    • /
    • pp.305-312
    • /
    • 2007
  • In this paper, we present a received signal strength (RSS) prediction model to timely Initiate link layer triggers for fast handoff in a wireless LAN system. Noting that the distance between a mobile terminal and an access point is not changed abruptly in a short time interval, an adaptive RSS predictor based on a stationary time series model is proposed. RSS data obtained from ns-2 simulations are used to identity the time series model and verify the predictability of the RSS data. The results suggest that an autoregressive process of order 1 (AR(1)) can be used to represent the measured RSSs in a short time interval and predict at least 1-step ahead RSS with a high confidence level.