• Title/Summary/Keyword: Trichloroethylene

Search Result 341, Processing Time 0.029 seconds

Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process (접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가)

  • Jaemin Woo;Dongjun Kim;Jihun Shin;Gihong Min;Chaekwan Lee;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

Phytochemical and Anti-Termite Efficiency Study of Guibourtia tessmanii (harms) J. Léonard (Kévazingo) Bark Extracts from Gabon

  • NKOGO, Ley-Fleury ELLA;BOPENGA, Christ Stone Arnaud BOPENGA;NGOHANG, Franck Estime;MENGOME, Line Edwige;ANGONE, Sophie ABOUGHE;ENGONGA, Prosper EDOU
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.113-125
    • /
    • 2022
  • This study aimed to explore the biodiversity of chemical compounds found in the bark of Guibourtia tessmannii from Gabon, commonly called Kévazingo, and evaluate their anti-termite activity to determine their potential values as a source of development of anti-termite products that can be valued in the fields of fine chemicals and wood preservation. Extraction of G. tessmannii bark powders was carried out using the cold maceration method with trichloroethylene, acetone, ethanol, and water. Phytochemical screening made it possible to highlight groups of chemical families present in the extracts. Anti-termite activity was tested on the wild termites "Cubitermes sp" of the genus Isoptera. The yield of the extracts were 17.11% for the buttress and 13.42% for the height at 6 m. Phytochemical tests revealed that alkaloids, polyphenols, sterols, tannins, reducing compounds, flavonoids, saponins, and anthraquinones were present in the extracts. Results of anti-termite activity indicated that anti-termite activity varied with the different parts of the bark studied, extraction solvent, and concentration (50/50) and (25/75) of the extracts used. The extracts at 50/50 concentration showed a slightly better anti-termite activity compared to the 25/75 concentration. In addition, the buttress Kévazingo or buttress showed the strongest anti-termite activity for the aqueous extract with a survival rate of 0% after 2 days.

Estimating anaerobic reductive dechlorination of chlorinated compounds in groundwater by indigenous microorganisms

  • Park, Sunhwa;Kim, Deok Hyun;Yoon, JongHyun;Kwon, JongBeom;Choi, Hyojung;Kim, Ki-In;Han, Kyungjin;Kim, Moonsu;Shin, Sun-Kyoung;Kim, Hyun-Koo
    • Membrane and Water Treatment
    • /
    • v.13 no.2
    • /
    • pp.85-95
    • /
    • 2022
  • Tetrachloroethylene (PCE) and trichloroethylene (TCE), critical pollutants to human health and groundwater ecosystems, are managed by groundwater quality standards (GQS) in South Korea. However, there are no GQSs for their by-products, such as cis-dichloroethylene (DCE) and vinyl chloride (VC) produced through the dechlorination process of PCE and TCE. Therefore, in this study, we monitored PCE, TCE, cis-DCE, and VC in 111 national groundwater wells for three years (2016 to 2018) to evaluate their distributions, a biological dechlorination possibility, and human risk assessment. The detection frequency of them was 30.2% for PCE, 45.1% for TCE, 43.9% for cis-DCE and 13.4% for VC. The four chlorinated compounds were commonly detected in 21 out of 111 wells. In the results of statistical analysis with 21 wells data, DO and ORP also had a negative correlation with four organic chlorinated compounds, while EC and sulfate has a positive correlation with the compounds. This indicates that the 21 wells were relatively met with suitable environments for a biological dechlorination reaction compared to the other wells. Finally, cis-DCE had a non-carcinogenic risk of 10-1 and the carcinogenic risk of VC was 10-6 or higher. Through this study, the distribution status of the four chlorinated compounds in groundwater in South Korea and the necessity of preparing plans to manage cis-DCE and VC were confirmed.

Present Trend and Prospect of Catalyst Technology at Room Temperature for Controlling Indoor Air Quality (IAQ) (실내대기오염물질 제어를 위한 상온산화 촉매 기술의 동향과 전망)

  • Lee, Sang-Hyun;Kim, Sung Su
    • Prospectives of Industrial Chemistry
    • /
    • v.19 no.5
    • /
    • pp.1-11
    • /
    • 2016
  • 우리나라는 1970년대를 기점으로 하여 급격한 경제성장과 산업기술의 발전이 이루어졌다. 경제성장과 함께 주택의 보급 또한 급격하게 증가하게 되었고, 주택의 보급을 위한 건축자재 및 생활용품의 개발이 급속도로 이루어졌다. 이에 따라 실내에서 사용하는 기구 및 건축재료가 매우 다양해졌으며, 이로 인한 새로운 오염물질의 배출이 급격히 증가하게 되었다. 최근 새로운 기술로 소개되고 있는 촉매 산화법의 경우 제거하려는 대상 실내대기오염물질을 촉매를 이용하여 CO2나 H2O 등으로 산화시켜 제거하는 방법이며, 최근 많은 연구가 활발하게 수행되고 있다. 촉매를 이용하는 촉매 산화법은 광촉매 산화법과, 촉매의 성능만을 이용하여 대상물질을 산화하는 촉매산화법으로 구분된다. 광촉매 산화법은 특정 파장에서 반응하는 촉매에 자외선을 조사하여 실내오염물질을 산화제거하는 방법으로, 산화성능이 우수하여 여러 가지 실내오염가스에 적용되고 있으나, 별도의 광원이 필요하며, 포름알데히드 산화 시 CO2와 H2O 이외에도 dichloroacetyl chloride (C2HCl3O), trichloroethylene (C2HCl3), phosgene (COCl2) 등과 같은 부수적인 2차 유해물질이 발생함에 따라 이를 처리하기 위한 대책이 수반되어야 한다. 반면, 촉매 산화법의 경우 별도의 광원이나 에너지원 없이, 촉매를 이용하여 대기오염물질을 인체에 무해한 물질로 완전 산화시키는 방법으로써, 최근 많은 연구가 수행되어 상온에서 구동 가능한 촉매가 개발되었고, 이의 연구가 활발히 이루어지고 있다. 이에 상온산화촉매기술의 연구동향 및 사례를 확인하고, 향후 상온산화촉매기술이 나아가야 할 방향을 제시하고자 한다. 본 연구는 환경부 환경산업선진화기술개발사업의 지원을 받아 수행되었습니다(2016000140004).

Association with Combined Occupational Hazards Exposure and Risk of Metabolic Syndrome: A Workers' Health Examination Cohort 2012-2021

  • Dongmug Kang ;Eun-Soo Lee ;Tae-Kyoung Kim;Yoon-Ji Kim ;Seungho Lee ;Woojoo Lee ;Hyunman Sim ;Se-Yeong Kim
    • Safety and Health at Work
    • /
    • v.14 no.3
    • /
    • pp.279-286
    • /
    • 2023
  • Background: This study aimed to evaluate the association between exposure to occupational hazards and the metabolic syndrome. A secondary objective was to analyze the additive and multiplicative effects of exposure to risk factors. Methods: This retrospective cohort was based on 31,615 health examinees at the Pusan National University Yangsan Hospital in Republic of Korea from 2012-2021. Demographic and behavior-related risk factors were treated as confounding factors, whereas three physical factors, 19 organic solvents and aerosols, and 13 metals and dust were considered occupational risk factors. Time-dependent Cox regression analysis was used to calculate hazard ratios. Results: The risk of metabolic syndrome was significantly higher in night shift workers (hazard ratio = 1.45: 95% confidence interval = 1.36-1.54) and workers who were exposed to noise (1.15:1.07-1.24). Exposure to some other risk factors was also significantly associated with a higher risk of metabolic syndrome. They were dimethylformamide, acetonitrile, trichloroethylene, xylene, styrene, toluene, dichloromethane, copper, antimony, lead, copper, iron, welding fume, and manganese. Among the 28 significant pairs, 19 exhibited both positive additive and multiplicative effects. Conclusions: Exposure to single or combined occupational risk factors may increase the risk of developing metabolic syndrome. Working conditions should be monitored and improved to reduce exposure to occupational hazards and prevent the development of the metabolic syndrome.

Control of Chlorinated Volatile Pollutants at Indoor Air Levels Using Polymer-based Photocatalyst, Composite

  • Kim, Byeong-Chan;Kim, Hye-Jin;Kim, Ji-Eun;Park, Eun-Ju;Noh, Ji-Sun;Kang, Hyun-Jung;Shin, Seung-Ho;Jo, Wan-Kuen
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.105-112
    • /
    • 2013
  • In this study, polyaniline (PANI)-based $TiO_2$ (PANI-$TiO_2$) composites calcined at different temperatures were prepared and their applications for control of trichloroethylene (TCE) and tetrachloroethylene (TTCE) at indoor air levels were investigated. For these target compounds, the photocatalytic control efficiencies of PANI-$TiO_2$ composites did not exhibit any trend with varying calcination temperatures (CTs). Rather, the average control efficiencies of PANI-$TiO_2$ composites over 3-h photocatalytic process increased from 61 to 72% and from 21 to 39% for TCE and TTCE, respectively, as the CT increased from 350 to $450^{\circ}C$. However, for both the target compounds, the average control efficiencies of PANI-$TiO_2$ composites decreased gradually as the CT increased further to 550 and $650^{\circ}C$. These results were ascribed to contents of anatase crystal phase and specific surface area of different particle sizes in the PANI-$TiO_2$ composites, which were demonstrated by the X-ray diffraction and scanning electron microscopy images, respectively. At the lowest input concentration (IC, 0.1 ppm), average control efficiencies of TCE and TTCE were 72 and 39%, respectively, whereas at the highest IC (1.0 ppm) they were 52 and 18%, respectively. As stream flow rate increased from 0.1 to 1.0 L $min^{-1}$, the average control efficiencies of TCE and TTCE decreased from ca. 100 to 47% and ca. 100 to 18%, respectively. In addition, the average control efficiencies of TCE and TTCE decreased from ca. 100 to 23% and ca. 100 to 8%, respectively as the relative humidity increased from 20 to 95%. Overall, these findings indicated that as-prepared PANI-$TiO_2$ composites could be used efficiently for control of chlorinated compounds at indoor air levels;if operational conditions were optimized.

A Study on the Method for Removing the Paraffin used on Iron Artifacts as Surface Coating Agent - As Focused on the Iron Artifacts Owned by the Kyunghee University Central Museum - (철제유물 표면코팅제로 사용된 파라핀 제거방법에 관한 연구 - 경희대학교박물관 소장 철제유물을 중심으로 -)

  • Kang, Seokin;Wi, Koangchul;Lee, Hoyeon;Lim, Seongjin
    • Conservation Science in Museum
    • /
    • v.13
    • /
    • pp.23-31
    • /
    • 2012
  • The object artifacts of this study are the iron artifacts owned by the Kyunghee University Central Museum. The surfaces of the iron artifacts are opaque due to the coated materials which are presumed to be paraffin or bee's wax while they are plate-shaped and exist in thickly exfoliated condition caused by severe corrosion developed on the overall surfaces. Therefore, in order to remove the coated materials away from the surfaces of the artifacts rather safely, reversibility tests have been carried out and the conservation treatment was performed upon the basis of and in application of the experimental results. The study methodologies are that: first, the FT-IR analysis was carried out to determine the ingredients of the coating-treated material on the surface; second, by applying various kinds of organic solvents, the kinds of agents that allow the artifact's surface-coating material to be reversible have been identified through experiments; third, the most suitable agent for removing coating material was selected and applied to the real artifacts on the basis of the results of the reversibility tests. Results from the study: first, as a result of the FT-IR analysis, the coating agent used on the artifacts was identified to be of the same ingredients as those of paraffin; second, among organic solvents, xylene, toluene, trichloroethylene and methyl alcohol were identified to be usable for dissolving paraffin whereas toluene was judged to be the most suitable for removing the coating agent; third, when applying the selected agents on the real artifacts, due to the fact that removing the whole paraffin might cause the artifact to disintegrate, the paraffin of only the part that covered the surfaces opaquely was removed using cotton swab or gauze, thus completing the conservation treatment.

Study on characteristics of specific hazardous substances in the industrial wastewater effluent (사업장 방류수 중 특정수질유해물질 배출 특성 연구)

  • Kim, Seungho;Choi, Youngseop;Kim, Yunhee;Kim, Jongmin;Chang, Gilsik;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.114-125
    • /
    • 2016
  • In this study, 165 wastewater discharge facilities in 10 business types were investigated with regard to 24 specific hazardous substances that included heavy metals, VOCs, CN, and phenol in the Gwangju city. Cu in the range from from 0.008 to 35.420 mg/L was detected in all business types and the detection rate was 46.8 %. Other heavy metals, such as Cd, As, Hg, Pb, and Cr+6 were detected as well. However, their detection rates ranged between 0.6 and 1.8 %. CN and phenol were detected in one and five facilities, respectively. 12 species of VOCs were detected: chloroform 80.6 % (0.42 to 81.60 μg/L), benzene 16.4 % (1.49 to 3.31 μg/L), trichloroethylene 11.5 % (1.78 to 6.02 μg/L), 1,1-dichloroethylene 10.3 % (1.23 to 5.89 μg/L), and dichloromethane 8.5 % (0.28 to 968.86 μg/L) in the detection rate order. The concentration of VOCs was detected in trace amounts, except for dichloromethane that exceeded the effluent quality standard in three business types, namely, metal manufacturing, food industry, and car washing facility. Chloroform was detected in all business types, where 24.88 μg/L were detected in the laundry business and 53.41 μg/L in the water supply business; the mean concentration of chloroform in these two business types was higher than elsewhere. Therefore, for the disposal of non-degradable specific hazardous substances in industrial wastewater, it is necessary to introduce physical and chemical processes, such as activated carbon adsorption, fenton oxidation, ozone treatment, as well as photocatalyst and the UV radiation.

Evaluation of Microbial PCE Reductive Dechlorination Activity and Microbial Community Structure using PCE-Contaminated Groundwater in Korea (사염화에틸렌(PCE)으로 오염된 국내 4개 지역 지하수 내 생물학적 PCE 탈염소화 활성 및 미생물 군집의 비교)

  • Kim Young;Kim Jin-Wook;Ha Chul-Yoon;Kwon Soo-Yeol;Kim Jung-Kwan;Lee Han-Woong;Ha Joon-Soo;Park Hoo-Won;Ahn Young-Ho;Lee Jin-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.52-58
    • /
    • 2005
  • In Korea, little attention has been paid to microbial perchloroethylene (PCE) and/or trichloroethylene (TCE) dechlorination activity and identification of microorganisms involved in PCE reductive dechlorination at a PCE-contaminated aquifer. We performed microcosm tests using the groundwater samples from 4 different contaminated sites (i.e. Changwon A, Changwon B, Bucheon and Yangsan) to assess PCE reductive dechlorination activity. We also adapted molecular techniques to screen what types of known reductive dechlorinators are present at the PCE-contaminated aquifers. In the Changwon A and Changwon B active microcosms where potential electron donors such as sodium propionate, sodium lactate, sodium butyrate, and sodium fumarate, were added, ethylene, an end-product of complete reductive dechlorination of PCE, was detected after a period of 90 days of incubation. In the Bucheon and Yangsan active microcosms, cis-1,2-dichloroethylene (c-DCE) was accumulated without the production of vinyl chloride (VC) and ethylene. Molecular techniques were used to evaluate the microbial community structures in the Changwon B and Yangsan aquifer. We found two sequence types that were closely related to a known PCE to ethylene dechlorinator, named uncultured bacterium clone DCE47, in the Changwon B site clone library. However, in the Yangsan site clone library, no sequence type was closely related to known PCE dechlorinators reported. It is plausible that microorganisms being capable of completely dechlorinating PCE to ethylene may be present in the Changwon B site aquifer. In this study we find that complete PCE reductive dechlorinators are present at some PCE-contaminated sites in Korea. In an engineering point of view this information makes it feasible to apply a biological reductive dechlorination process for remediating PCE- and/or TCE-contaminated aquifers in Korea.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.