• 제목/요약/키워드: Triangular Number

검색결과 303건 처리시간 0.024초

삼각형 내부냉각유로에 설치된 다양한 형태의 리브에 관한 수치해석적 연구 (Numerical Study on Various Ribs in a Triangular Internal Cooling Channel)

  • 박민정;문미애;김광용
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.19-26
    • /
    • 2012
  • In this paper, a parametric study on ribs which are installed in an equilateral triangular internal cooling channel is presented. The numerical analysis of the flow structure and heat transfer characteristics is performed using three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model. The numerical results are obtained at Reynolds number, 20,000. The parametric study is performed for the parameters, the angle of a rib, rib pitch-to-hydraulic diameter ratio, rib width-to-hydraulic diameter ratio, and rib height-to-hydraulic diameter ratio. The computational results are validated with the experimental data for area-averaged Nusselt number.

PARAMETRIC INVESTIGATIONS ON THE DOUBLE DIFFUSIVE CONVECTION IN TRIANGULAR CAVITY

  • Kwon, SunJoo;Oh, SeYoung;Yun, Jae Heon;Chung, Sei-Young
    • 충청수학회지
    • /
    • 제20권4호
    • /
    • pp.419-432
    • /
    • 2007
  • Double-diffusive convection inside a triangular porous cavity is studied numerically. Galerkin finite element method is adopted to derive the discrete form of the governing differential equations. The first-order backward Euler scheme is used for temporal discretization with the second-order Adams-Bashforth scheme for the convection terms in the energy and species conservation equations. The Boussinesq-Oberbeck approximation is used to calculate the density dependence on the temperature and concentration fields. A parametric study is performed with the Lewis number, the Rayleigh number, the buoyancy ratio, and the shape of the triangle. The effect of gravity orientation is considered also. Results obtained include the flow, temperature, and concentration fields. The differences induced by varying physical parameters are analyzed and discussed. It is found that the heat transfer rate is sensitive to the shape of the triangles. For the given geometries, buoyancy ratio and Rayleigh numbers are the dominating parameters controlling the heat transfer.

  • PDF

핀끝이 절연되었다는 가정하에 삼각핀 해석에서의 오차 (Errors in the Triangular Fin Analysis under Assuming the Fin Tip is Insulated)

  • 강형석;김성준
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1783-1788
    • /
    • 1994
  • A comparison of the temperature distributions along the wall and center of the fin and the heat loss from the fin, computed assuming the fin tip is insulated and assuming it is not insulated in a triangular fin, is performed by the two-dimensional forced analytic method. When the fin tip is not insulated, a comparison between forced analytic method and analytic method is made in the heat loss and temperature along the fin wall. The value of Biot number varies from 0.01 to 1.0. The root temperature and surrounding convection coefficients of the fin are assumed as a constant. The results are (1) the analysis on the triangular fin assuming the fin tip is insulated does not produce a good value as compared to that of not-insulated case as the non-dimensional fin length decreases and as the value of Biot number increases and (2) the errors between forced analytic method and analytic method are very small, but the former method is better for computer running time and accuracy.

Sharp Shape를 유지하는 trimmed NURBS 곡면의 삼각화 방법 (Trimmed NURBS surface tessellation with sharp shape constraint)

  • 조두연;김인일;이규열;김태완
    • 한국게임학회 논문지
    • /
    • 제2권1호
    • /
    • pp.62-68
    • /
    • 2002
  • 본 연구에서는 기존의 곡면 삼각화 방법들이 많은 수의 삼각형 메쉬를 사용하면서도 정확하게 표현하기가 힘들었던, 날카로운 모서리를 가지는 곡면을 처리할 수 있는 trammed NURBS곡면 삼각화 방법을 제안, 구현하였다. 기존의 매개변수영역에서의 삼각화의 문제점인 3차원공간상의 삼각형 메쉬를 계산할 때의 왜곡현상을 해결하기 위해서 곡면의 펼친영역을 근사적으로 계산하여 삼각화 하는 방법을 사용했다. 곡선, 곡면의 날카로운 점과 모서리를 자동으로 인식하기 위해서 1차미분 연속조건을 이용하였고, 이를 제약조건으로 constraint Delaunay 삼각화방법을 사용하여 곡면의 날카로운 형상(sharp shape)을 유지하면서 삼각화를 수행할 수 있었다. 제안된 삼각화 방법은 기존의 삼각화 방법에 비하여 적은수의 삼각형 메쉬로 곡면의 날카로운 모서리를 보다 정확하게 표현 할 수 있는 장점을 가지고 있어서 삼각형의 개수에 따라 가시화 성능이 큰 영향을 받는 컴퓨터게임 같은 분야에 도움을 줄 수 있으리라 예상된다.

  • PDF

액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향 (The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor)

  • 남호윤;김종만;최종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF

LINEAR STABILITY OF TRIANGULAR EQUILIBRIUM POINTS IN THE PHOTOGRAVITATIONAL RESTRICTED THREE BODY PROBLEM WITH TRIAXIAL RIGID BODIES, WITH THE BIGGER ONE AN OBLATE SPHEROID AND SOURCE OF RADIATION

  • KUMAR, AVDHESH;ISHWAR, B.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.297-299
    • /
    • 2015
  • In this paper we have examined the linear stability of triangular equilibrium points in the photogravitational restricted three body problem when both primaries are triaxial rigid bodies, the bigger one an oblate spheroid and source of radiation. The orbits about the Lagrangian equilibrium points are important for scientific investigation. A number of space missions have been completed and some are being proposed by various space agencies. We analyze the periodic motion in the neighbourhood of the Lagrangian equilibrium points as a function of the value of the mass parameter. Periodic orbits of an infinitesimal mass in the vicinity of the equilibrium points are studied analytically and numerically. The linear stability of triangular equilibrium points in the photogravitational restricted three body problem with Poynting-Robertson drag when both primaries are oblate spheroids has been examined by A. Kumar (2007). We have found the equations of motion and triangular equilibrium points for our problem. With the help of the characteristic equation we have discussed stability conditions. Finally, triangular equilibrium points are stable in the linear sense. It is further seen that the triangular points have long or short periodic elliptical orbits in the same range of ${\mu}$.

Fuzzy analysis for stability of steel frame with fixity factor modeled as triangular fuzzy number

  • Tran, Thanh Viet;Vu, Quoc Anh;Le, Xuan Huynh
    • Advances in Computational Design
    • /
    • 제2권1호
    • /
    • pp.29-42
    • /
    • 2017
  • This study presents algorithms for determining the fuzzy critical loads of planar steel frame structures with fixity factors of beam - column and column - base connections are modeled as triangular fuzzy numbers. The finite element method with linear elastic semi-rigid connection and Response Surface Method (RSM) in mathematical statistic are applied for problems with symmetric triangular fuzzy numbers. The ${\alpha}$ - level optimization using the Differential Evolution (DE) involving integrated finite element modeling is proposed to apply for problems with any triangular fuzzy numbers. The advantage of the proposed methodologies is demonstrated through some example problems relating to for the twenty - story, four - bay planar steel frames.

Comparing U. S. and Taiwanese Pre-service Teachers' Solving Triangular Arithmagons

  • LIN, Cheng-Yao;KUO, Yu-Chun
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제19권2호
    • /
    • pp.89-100
    • /
    • 2015
  • The study investigated pre-service teachers' knowledge and computational skills by using Triangular Arithmagon. Participants included 90 pre-service teachers from two schools in the United States and Taiwan. The Triangular Arithmagons Test (TAT) was used to measure pre-service teachers' performance in whole number, fractions, and decimals operations (i.e., addition, subtraction, multiplication, and division), each of which included level-1 (basic) and level-2 (advanced) tests. MANOVA analysis was performed to compare the performance between teachers from the United States and Taiwan. Results indicated that overall, pre-service teachers in Taiwan outperformed those in the United States, especially on the advanced-level tests. Pre-service teachers in the United States were found to have poor ability of solving complex operation problems. Different curriculum plans and teaching methods may lead to the performance gap between the two countries.

DIFFERENCE CORDIALITY OF SOME SNAKE GRAPHS

  • Ponraj, R.;Narayanan, S. Sathish
    • Journal of applied mathematics & informatics
    • /
    • 제32권3_4호
    • /
    • pp.377-387
    • /
    • 2014
  • Let G be a (p, q) graph. Let f be a map from V (G) to {1, 2, ${\ldots}$, p}. For each edge uv, assign the label ${\mid}f(u)-f(\nu){\mid}$. f is called a difference cordial labeling if f is a one to one map and ${\mid}e_f(0)-e_f(1){\mid}{\leq}1$ where $e_f(1)$ and $e_f(0)$ denote the number of edges labeled with 1 and not labeled with 1 respectively. A graph with admits a difference cordial labeling is called a difference cordial graph. In this paper, we investigate the difference cordial labeling behavior of triangular snake, Quadrilateral snake, double triangular snake, double quadrilateral snake and alternate snakes.

삼각형 멀티 탭을 이용한 충돌제트 열전달 향상 연구 (Enhancement of Impinging Jet Heat Transfer Using Triangular Multi-Tabs)

  • 이정욱;이상준
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1139-1146
    • /
    • 2004
  • The effect of triangular tabs attached at the perimeter of jet nozzle on heat transfer enhancement was investigated experimentally. The modified flow structure was visualized using a smoke-wire method. Four different types of jet nozzle having 0, 4, 6 and 8 tabs were tested at jet Reynolds number Re=15,000 to investigate the effect of tabs on the variation of heat transfer rate. The local and average Nusselt numbers are increased with increasing the number of tabs. At nozzle-to-plate distance of L/D=4, the average Nusselt number was increased about 9.9% at Re=15,000 in the impingement region for the case of 8 tabs attachment. As the nozzle-to-plate distance increases, however, the heat transfer enhancement effect of triangular tabs is reduced. For the case of 4 tabs, the heat transfer enhancement is not so distinctive at L/D=8. As the protrusion depth of tabs into the jet flow increases, the heat transfer rate is also enhanced when the nozzle-to-plate distance is smaller than L/D=6.