• Title/Summary/Keyword: Trial lenses

Search Result 16, Processing Time 0.018 seconds

Comparative Analysis of Refractive Power on Trial Case Lenses (검안렌즈의 굴절력 비교 분석)

  • Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.321-334
    • /
    • 2012
  • Purpose: In this study, the distribution and differences in refractive powers on trial case lenses were investigated. Methods: We measured refractive powers at optical center and periphery using 4 trial case lens sets. According to international standards, the distribution and uniformity in refractive powers were investigated. Results: The lens shapes were different in different kinds of trial case lenses and some of lenses were out of tolerance according international standards. In some cases, the power differences were found between front and back side as well as between optical center and peripheral regions and also the cylindrical power on spherical lens and spherical power on the cylindrical lens were measured. Conclusions: Trial case lens are used to assess the refractive error, therefore, more precise control of the manufacturing process for trial case lenses and more thorough quality control will be required to offer an accurate vision test. More careful attention in using trial case lens is also required.

A Study on Assessment of MTF Performance and Theoretical Analysis of Convex Trial Lenses (볼록 검안렌즈의 MTF 성능 분석 및 이론적 해석에 대한 연구)

  • Bang, Hyun Jin;Lee, Jong Ung;Son, Byung Ho;Ahn, Kyo Hoon;Choi, Eun Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.217-223
    • /
    • 2013
  • White light MTF(Modulation Transter Function)s of biconvex trial lenses from 10 to 20 diopter (D) were represented as a function of angular frequency and visual acuity, and then they were compared with AIM(Aerial Image Modulation) curves. All of the biconvex trial lenses evaluated in on-axis mode had MTF performance that could resolve Landolt's ring up to visual acuity 2.0. However, in a half field angle of five degrees, the trial lens of 10 diopters was able to resolve Landolt's ring up to visual acuity 0.9, and that of 20 diopter only up to visual acuity 0.8. This means that the trial lenses in the case of a half field angle of five degrees do not have sufficient resolution to measure visual acuity by 1.0.

Study on Mounting Status of Trial Case Lenses (검안렌즈의 장착상태에 대한 연구)

  • Cho, Hyun-Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.405-411
    • /
    • 2013
  • Purpose: In this study, the mounting status of trial case lens was investigated. Methods: We measured distances between geometric center of lens mount and optical center of lens and angle deviations between axis mark on lens and real axis using arbitrary trial case lens sets distributed in Korea, and then, compared those results with international standards. Results: In some of lenses, the prismatic power on geometric center of lens mount and the angle deviations between axis mark and real axis of cylindrical lens were out of tolerance according international standards. Conclusions: The more precise control of the manufacturing process and more thorough quality control for trial case lenses will be required to offer an accurate vision test.

The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops (안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태)

  • Park, Mijung;Lee, Unjung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.391-401
    • /
    • 2011
  • Purpose: In the present study, the actual management state of trial contact lenses and lens care products in local optical shops was surveyed and analyzed to reduce the risk of lens complication possibly induced by neglecting lens care. Methods: The feeling of contact lens wearers during the wear of trial contact lenses was surveyed. Futhermore, the actual management state of trial contact lenses such as cosmetic lens and RGP lens and lens care products was also investigated by surveying opticians who trade contact lenses in local optical shops. Results: It was found that consumers trusted the sanitary conditions of the lens since trial cosmetic contact lens and RGP lens were cleaned before and after trails by over 98% of opticians in local optical shops. For trial cosmetic lens, cleaning with normal saline, multipurpose solution for soft lens and combination of saline and multipurpose solution were 38.5%, 40.5% and 21%, respectively, before trials. After trials, cosmetic lenses were cleaned with normal saline, multipurpose solution for soft lens and a combination of saline and multipurpose solution were 13%, 75%, and 12%, respectively. On the other hand, cleaning with normal saline, multipurpose solution for RGP lens and combination of saline and multipurpose solution were 28.5%, 38.5% and 33%, respectively, before trying trial RGP lens. After trials, RGP lenses were cleaned with normal saline, multipurpose solution for RGP lens and a combination of saline and multipurpose solution were 2.5%, 70%, and 27.5%, respectively, indicating that relatively many opticians followed the lens cleaning regimen. In local optical shops, the cleaning trial cosmetic lens was mainly conducted at every 10 days or a month and the washing cycle of cosmetic lens case was in a month or 2~3 months. The cleaning interval of trial RGP lens was primarily in a month or 2~3 months. For those lens cases, more than 75% of opticians washed them with a surfactant and then rinsed with cold water. The storing periods of lens care products were primarily in a week for saline and in a month and 2~3 months indicating that storing period of lens care products was relatively well-kept in local optical shops. Conclusions: It is thought that the concern about any microbial infection is not that high since trial contact lenses and lens care products were generally well-managed by opticians in local optical shops from the results above. However, better public eye health and better public confidence in opticians may be possible if further strengthen in avoidance of lens cleaning with saline, keep of cleaning cycles within 2 weeks and rinsing of lens cases with hot water happens.

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

Empirical Fitting Curve for Luminous Transmittance in Tinted Lenses Using Superposition of Exponential Decay Curves (지수감소곡선의 중첩을 이용한 착색렌즈 시감투과율의 실험적 맞춤곡선)

  • Choi, Eun Jung;Lee, Sin Ui;Lee, Eun Jin;Yoon, Moon Joo;Jeong, Ji-Hyeon;Kim, Chang-Jin;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.283-291
    • /
    • 2011
  • Purpose: To find an empirical fitting curve to represent the relationship between the luminous transmittance and tinted time in tinted lenses using exponential decay curves. Methods: Total ninety tinted lenses were prepared with CR-39 lenses and six different colored dyes. Single, double and triple exponential decay curves were used as trial curves in order to find the empirical fitting curve. Result: The results showed that the best empirical fitting curve was triple exponential decay curves. Conclusions: We propose triple exponential decay curves as proper empirical fitting curves to represent the tinted-time dependence of the luminous transmittance in tinted lenses.

Changes of Visual Acuity and Visual Function in the Elderly Generation and their Subjective Satisfaction by the Use of Tinted Ophthalmic Lenses (착색안경렌즈의 사용에 따른 노년층의 시력 및 시기능 변화와 자각적 만족도)

  • Ryu, Deok-Hyeon;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Purpose: The study was aimed to suggest the most effective color of the tinted lenses by evaluating the effect of the prescription with tinted lenses on the visual quality of the elderly at the age of the sixty or more. Methods: The visual acuity of fifty subjects at the age of sixty or more (17 males, 33 females with the averaged age of $71.0{\pm}6.3$) were corrected to have the visual acuity at a far distance of 0.5 or more using a trial lens frame, and non-tinted, brown-tinted, and gray-tinted lenses were randomly applied on the trial frame. The minimum legibility and minimum separability were measured at a far distance in the aspect of the visual acuity and calculated as LogMAR and then, the visual acuity was compared. The stereopsis and contrast sensitivity were also estimated at a near distance in the aspect of the visual function. The participants' preference for tinted lenses and their subjective symptoms of the visual perception and the movement were further surveyed. Results: The best minimum legibility and minimum separability was shown when wearing non-tinted lenses, and brown-tinted and gray-tinted lenses were in the next. The stereopsis and the contrast sensitivity at a near distance and the visual perception was the best when wearing brown-tinted lenses. It was surveyed that the subjective discomfort was the biggest when wearing gray-tinted lenses, and brown-tinted lenses were the best in the aspect of the subjective preference. Conclusions: As the result of this study, it was revealed that the visual acuity and visual function could be improved by the use of tinted ophthalmic lenses however, its change of visual acuity and visual function was not completely correlated with the subjective satisfaction. Therefore, the appropriate color of ophthalmic lenses should be selected in accordance with the individual visual perception and the main vision lifestyle in the elderly generation. From the present study, the use of non- or brown-tinted lens and brown- or gray-tinted lens can be recommended for distance work and near work, respectively, in the elderly generation under the illumination of about 1,000 lux.

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

The adsorption pattern of protein to the soft contact lens and its effect on the visible light transmission and the contact angle (소프트콘택트렌즈의 단백질 부착 양상 및 가시광선투과도와 접촉각에 미치는 영향)

  • Park, Mijung;Kwon, Mi Jeong;Lee, Sun Hee;Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.53-68
    • /
    • 2004
  • Protein deposit buildup on soft contact lenses(SCLs) is responsible for discomfort, optical defects and is even damaging to the eye. To better understand protein deposit formation on SCL, we investigated the pattern of protein attachment on patient-worn SCLs and the effect of the protein on the contact angle of SCLs and the transmission of visible light. This study used data from a clinical trial where subjects wore either daily-wear SCL(etafilcon A, N=40) for various period up to 14 days, or extended-wear SCL(balafilcon A, N=40) for 8 h day or night. The adsorption of protein in daily-wear SCLs was significantly increased in patient-worn time-dependent manner although the lenses were cleaned everyday by using the multi-purpose SCL solution. After 2 weeks wearing, the protein on the SCL influenced the contact angle of the lenses. Furthermore, the transmission of visible light of the lenses decreased up to almost 7%. Extended-wear SCLs worn during the closed eye condition were found to deposit significantly more protein than SCLs worn during the open eye condition. The amounts of protein adsorbed both after daily SCL wear and after overnight SCL wear were not affected the contact angle and the transmission of visible light of the lenses. The protein deposit buildup on SCL related to the corneal temperature and pH of tear fluid.

  • PDF

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.