• 제목/요약/키워드: Treeing deterioration

검색결과 26건 처리시간 0.028초

Effect of an Electric Field on the AC Electrical Treeing in Various Epoxy/Reactive Diluent Systems

  • Bang, Jeong-Hwan;Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.308-311
    • /
    • 2013
  • The effect of an electric field on the ac electrical treeing in various epoxy/reactive diluent systems was studied in a needle-plate electrode geometry. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the treeing initiation time and the propagation rate, three constant alternating currents (ac) of 10, 13 and 15 kV/4.2 mm (60 Hz) were applied to the specimen, in a needle-plate electrode arrangement, at $30^{\circ}C$ of insulating oil bath. When 10 kV/4.2 mm (60 Hz) was applied, the treeing initiation time and the propagation rate in the DGEBA system were 356 min and $1.10{\times}10^{-3}$ mm/min, respectively, those in the DGEBA/BDGE system were 150 min and $1.14{\times}10^{-3}$ mm/min, respectively. Those in the DGEBA/PG system were 469 min and $1.05{\times}10^{-3}$ mm/min, respectively. As 15 kV/4.2 mm (60 Hz) was applied, the propagation rate in the DGEBA system was $5.41{\times}10^{-3}$ mm/min, and that in the DGEBA/PG system was $1.42{\times}10^{-3}$ mm/min. These values meant that PG could be used as a reactive diluent in the DGEBA system, without the deterioration of the insulation breakdown property.

저밀도폴리에틸렌에서 무기질의 충전분이 Treeing 진전에 미치는 영향 (Effect of inorganic filler powder to development of treeing in low density polyethylene)

  • 김봉협;강도열;김정수;임기조
    • 전기의세계
    • /
    • 제29권8호
    • /
    • pp.524-531
    • /
    • 1980
  • In order to investigate the effect of inorganic dielectric fine particle mixed in Low Density Polyethylene on the deterioration by treeing, a comparative study for initiation and development of the tree has been carried out between the pure thin film specimen and the same geometrical specimen mixed with a constant weight percent by a defiend particle size of $Al_{2}$O$_{3}$ and SiO$_{2}$, having larger dielectric constants than that of the base material. According to the results, it has been observed that as increasing dielectric constant, the initiation of tree is expedited, however, the development of the tree reached at the surface of filler particles shows the suppressive trends. From these facts, a reasonable interpretation may be possible by considering the effect of intensified electrical field around the tip in the presence of filler particles, that the initiation and the development of tree are a mechanical break down process caused by Maxwell stress due to the concentration of electrical field at the tip. This suppressive effect is specifically suggestive for the reason that a discharge route must be constructed around the particle surface because of the intensified field strength near filler, which, in turn, reduces the geometrical curvature of the tip so that the local intensity of electrical field can be relaxed. Further more an experimental evidence for this assumption was able to observe in this investigation.

  • PDF

가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출 (Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

Corona방전에 의한 유전체의 열화현상 (The Deterioration Phenomena for Dielectrics Causing Corona Discharge)

  • 성영권;백영학;차균현
    • 전기의세계
    • /
    • 제19권6호
    • /
    • pp.18-25
    • /
    • 1970
  • The object of this project is to manifest the mechanism of deterioration phenomena for dielectrics causing corona discharge and applies it for determine the standard corona detection technique. As the results, we observed that corona discharges may occur more strongly around cylindrical shape electrode in air than hemisphere shape electrode in vacuum, so that it depends on effects such as shape of the electrode, moisture, surface coditions, etc. According to observed the deterioration of dielectrics takes place in following stages. At first the attacked surface by an electron avalanche is uniformly eroded; then pits are formed; after that sharp channels are formed which lead to break-down as a treeing. The test are accelerated with higher frequencies by the cylindrical bar shape electrode in the pulse stright detection method more sensitive than Lissajous patterns. Lissajous patterns detection method is simple but usually insensitive and has disadvantage that the magnitude of the individual discharge is not measured.

  • PDF

DGEBA/MDA/SN/HQ 계에서 발생하는 교류 트리의 프랙탈성 (Fractal Characteristics of AC Tree Grown in DGEBA/MDA/HQ System)

  • 조영신;심미자;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1588-1590
    • /
    • 1996
  • The fractal characteristics of AC electrical tree grown in DGEBA/MDA/ SN/HQ system was investigated. As the applied voltage decreased, tree initiated after retardation. All the trees were fractals in spite of tile applied voltage. Fractal dimension increased with tree length. When the tree grew slowly, the fractal dimension or tile degree of treeing deterioration increased.

  • PDF

음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구 (A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection)

  • 이덕진;신성권;김재환
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.68-74
    • /
    • 1999
  • 본 연구는 고분자재료에서 음향센서를 이용한 부분방전의 음향적 탐지를 행했다. 저밀도 폴리에틸렌에 대한 트리잉파괴 실험에서 음향센서로 얻어진 음향방출 특성의 시간순서대로 측정하여 통계처리를 행했다. 또한 5가지 특성량을 도입하고 $\psi$-AEA-n(위상-음향진폭-펄스수) 패턴을 분석한 결과, 보이드 시료의 AE평균개시진폭 $(\overline{AEA_{inc}})$과 AE 평균최대진폭$(\overline{AEA_{max}})$은 열화중기, AE펄스수, AE평균최대위상각$(\overline{\theta{max}})$은 열화말기를 진단하기 위해서 유용한 음향방출량임을 알 수 있다. 이들 음향방출량은 보이드 시료의 열화진단을 구별하는데 유용한 음향방출량임을 실험결과로부터 얻었다.

  • PDF

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권3호
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

프랙탈 특성과 음향방출 계측법을 이용한 LDPE 시료에서의 트리잉 파괴진단에 관한 연구 (A Study On the Diagnosis Breakdown Using Fractal Characteristics and the Method of Acoustic Emission in Low Density Polyethylene)

  • 윤헌주;박재준;신승중;최재관;김성홍;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1758-1760
    • /
    • 1997
  • Automatic detection system to detect acoustic emission pulse and fractal dimension were developed, to observe tree deterioration phenomena in LDPE. The purpose of our work are to use acoustic emission system and fractal dimension and to investigate the treeing phenomena in polymeric insulation under applied AC voltage 11[kV] with an artificial needle-shaped void(1.5[mm]) using the above system. We analyzed and phase angle-acoustic emission pulse amplitude-deterioration time ($\Phi$-AEA-t) pattern and phase angle-acoustic emission pulse number-deterioration time($\Phi$-AEN-t) pattern using statistical operators such as skewness, fractal dimension. In this paper show that the correlation of $\Phi$-AEA-t, $\Phi$-AEN-t, fractal dimension using regression analysis by the method of least squares can be used to predict the breakdown just before the breakdown occurs.

  • PDF