• Title/Summary/Keyword: Trapped Magnetic Particle

Search Result 12, Processing Time 0.02 seconds

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

In-situ Patterning of Magnetic Particles in Microfluidic Channels by Forward/Reverse Local Magnet Arrangement (국소 자기장의 순/역 배열을 이용한 미세유체 채널 내에서의 강자성 입자 패턴 형성)

  • Park, Hyoun-Hyang;Lee, Ji Hae;Yoo, Yeong Eun;Kim, Jung-Yup;Chang, Sunghwan
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.217-223
    • /
    • 2015
  • The patterning of microbead in microfluidics channel is a practical technique for application in bio and medical areas. An approach is described for a direct patterning of magnetically active microbeads in microfluidic devices without inner structure. Local magnet arrangements - flat arrangement and stack arrangement - contacting same poles or opposite poles of magnet were utilized for generating trapping magnetic fields. The arrangement of magnets contacting same poles generated isolated patterns by repelling of magnetic field. The flat arrangement of vertically reverse magnet arrays shaped trapping patterns repelling magnetic field line between same poles. Spatially, the stack compositions of magnet arrangements allow diverse isolated trapped patterns of magnetic particles. Trapped magnetic particles in fluidic channels were stable on the $18m{\ell}/hr$ flow conditions and magnetic force of 1.08 mT in the all experiments. This experimental study suggests the simple and versatile methods to pattern magnetic particles, and has potential of wide application to bio and medical area.

Photoionization of $TiO_2$ Particles Incorporated into Silica Gels Studied by EPR Spectroscopy

  • Ahn, Sang-Won;Kang, Kee-Hoon;Hong, Dea-Il
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.1
    • /
    • pp.50-63
    • /
    • 2000
  • Titanium dioxide particles with three different average sizes, prepared by three different methods, were incorporated into silica gel pores by impregnation. The titanium dioxide incorporated into the silica gel pores was photoionized by 240-400 nm irradiation at 77 K by a one-photon process to from trapped hole centers on OH group and trapped electron centers on titanium which were detected by electron paramagnetic resonance at 77 K. During the impregnation the smallest size range of TiO2 particles can be incorporated into silica gels with 2.5-1.5 nm pores. However, the largest size range of TiO2 particles can only be incorporated into silica gels with 6-15 nm pores and not into silica gels with 2.5-4 nm pores. The photoyield and stability of photoinduced hole and electron centers depends on the silica pore sizes of silica gels and surface area as well as on the TiO2 loading. In large pore silica gels and large particle size of TiO2, photoinduced charge separation reaches to a plateau at shorter irradiation times and the trapped hole and electron centers are more stable to decay.

  • PDF

Short-duration Electron Precipitation Studied by Test Particle Simulation

  • Lee, Jaejin;Kim, Kyung-Chan;Lee, Jong-Gil
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.317-325
    • /
    • 2015
  • Energy spectra of electron microbursts from 170 keV to 340 keV have been measured by the solid-state detectors aboard the low-altitude (680 km) polar-orbiting Korean STSAT-1 (Science and Technology SATellite). These measurements have revealed two important characteristics unique to the microbursts: (1) They are produced by a fast-loss cone-filling process in which the interaction time for pitch-angle scattering is less than 50 ms and (2) The e-folding energy of the perpendicular component is larger than that of the parallel component, and the loss cone is not completely filled by electrons. To understand how wave-particle interactions could generate microbursts, we performed a test particle simulation and investigated how the waves scattered electron pitch angles within the timescale required for microburst precipitation. The application of rising-frequency whistler-mode waves to electrons of different energies moving in a dipole magnetic field showed that chorus magnetic wave fields, rather than electric fields, were the main cause of microburst events, which implied that microbursts could be produced by a quasi-adiabatic process. In addition, the simulation results showed that high-energy electrons could resonate with chorus waves at high magnetic latitudes where the loss cone was larger, which might explain the decreased e-folding energy of precipitated microbursts compared to that of trapped electrons.

Liquid mist and videotape signal dropouts in gravure roll coating (Gravure롤 코팅방식에서 비산도료에 의한 비디오 신호의 dropouts)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.633-639
    • /
    • 1995
  • Dropouts in magnetic media are a primary quality deficiency which is detrimental to magnetic signal quality and thus the major impediment to error-free recording, especially in high density digital recorders. The specific form of defects and causes found to be responsible for signal dropouts occurring in magnetic tape were studied. Dropout occurred when the RF signal falls to low level due to the various types of surface defects. However, the fall in the level of the RF signal in gravure roll coated tapes was most often caused by foreign particles adhering to the magnetic tape. It was also shown from the present study that scattered particles trapped under the tape surface or put on the top can lift it as it crosses the head, creating a spherical tent shaped defect and causing a temporary signal drop. Dropout producing substances were identified through optical and microchemical analyses. The results were correlated with measured electrical signal losses combined with analytical microscopy to clarify source identification of defects.

  • PDF

Opto-electrokinetic Technique for Microfluidic Manipulation of Microorganism (광-전기역학 기술을 이용한 미생물의 미세유체역학적 제어)

  • Kwon, Jae-Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.69-77
    • /
    • 2019
  • This paper introduces microfluidic manipulation of microorganism by opto-electrokinetic technique, named rapid electrokinetic patterning (REP). REP is a hybrid method that utilizes the simultaneous application of a uniform electric field and a focused laser to manipulate various kinds and types of colloidal particles. Using the technique in preliminary experiments, we have successfully aggregated, translated, and trapped not only spherical polystyrene, latex, and magnetic particles but also ellipsoidal glass particles. Extending the manipulation target to cells, we attempted to manipulate saccharomyces cerevisiae (S. cerevisiae), the most commonly used microorganism for food fermentation and biomass production. As a result, S. cerevisiae were assembled and dynamically trapped by REP at arbitrary location on an electrode surface. It firmly establishes the usefulness of REP technique for development of a high-performance on-chip bioassay system.

Fabrication of a high magnetization YBCO bulk superconductor by a bottom-seeded melt growth method

  • Hong, Yi-Seul;Park, Soon-dong;Kim, Chan-Joong;Lee, Hee-Gyoun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.19-23
    • /
    • 2019
  • A large grain YBCO bulk superconductor is fabricated by the top-seeded melt growth (TSMG) method. In the TSMG process, the seed crystal is placed on the top surface of a partially melted compact and therefore the seed crystal is frequently tilted during the melt process due to intrinsic unstable nature of Y211 particle +liquid phase mixture. In this work, we report the successful growth of single-domain YBCO bulk superconductors by a bottom-seeded melt growth (BSMG) method. Investigations on the trapped magnetic field and the microstructures of the synthesized specimens show that a bottom-seeded melt growth method has hardly affected on the crystal growth behavior, the microstructure development and the magnetic properties of the large grain YBCO bulk superconductors. The bottom-seeded melt growth method is clearly beneficial for the stable control of seed orientation through the melt process for the fabrication of a large grain YBCO bulk superconductor.

Conceptual Design of Sandglass-like Separator for Immobilized Anionic Radionuclides Using Particle Tracking Based on Computational Fluid Dynamics

  • Park, Tae-Jin;Choi, Young-Chul;Ham, Jiwoong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.363-372
    • /
    • 2020
  • Anionic radionuclides pose one of the highest risks to the long-term safety assessments of disposal repositories. Therefore, techniques to immobilize and separate such anionic radionuclides are of crucial importance from the viewpoints of safety and waste volume reduction. The main objective of this study is to design a separator with minimum pressure disturbance, based on the concept of a conventional cyclone separator. We hypothesize that the anionic radionuclides can be immobilized onto a nanomaterial-based substrate and that the particles generated in the process can flow via water. These particles are denser than water; hence, they can be trapped within the cyclone-type separator because of its design. We conducted particle tracking analysis using computational fluid dynamics (CFD) for the conventional cyclone separator and studied the effects due to the morphology of the separator. The proposed sandglass-like design of the separator shows promising results (i.e., only one out of 10,000 particles escaped to the outlet from the separation zone). To validate the design, we manufactured a laboratory-scale prototype separator and tested it for iron particles; the efficiency was ca. 99%. Furthermore, using an additional magnetic effect with the separator, we could effectively separate particles with ~100% efficiency. The proposed sandglass-like separator can thus be used for effective separation and recovery of immobilized anionic radionuclides.

Electron Microburst Generation by Wave Particle Interaction

  • Lee, Jae-Jin;Hwang, Jung-A;Parks, George K.;Min, Kyoung-Wook;Lee, En-Sang
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.43.2-43.2
    • /
    • 2009
  • Electron microbursts are the intense electron precipitation which durations are less than one second. We measured the energy spectra of the microbursts from 170 keV to 340 keV with solid state detectors aboard the low-altitude (680km), polar-orbiting Korean STSAT-1 (Science and Technology SATellite). The data showed that the loss cone at these energies is empty except when microbursts abruptly appear and fill the loss cone in less than 50 msec. This fast loss cone filling requires pitch angle diffusion coefficients larger than ~ 10-2rad2/sec, while ~10-5 rad2/sec was proposed by a wave particle interaction theory. We recalculated the diffusion coefficient, and reviewed of electron microburst generation mechanism with test particle simulations. This simulation successfully explained how chorus waves make pitch angle diffusion within such short period. From considering the resonance condition between wave and electrons, we also showed ~ 100 keV electrons could be easily aligned to the magnetic field, while ~ 1MeV electrons filled loss cone partially. This consideration explained why precipitating microbursts have lower e-folding energy than that of quasi-trapped electrons, and supports the theory that relativistic electron microbursts that have been observed by satellite in-situ measurement have same origin with ~100 keV electron microbursts that have been usually observed by balloon experiments.

  • PDF

Method of simultaneous synthesize for Y123 and Y211 and fabrication of YBCO single crystal (Y123와 Y211분말의 동시 합성과 YBCO 초전도 단결정 제조)

  • 안재원;최희락;한영희;한상철;정년호;성태현
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.05a
    • /
    • pp.224-233
    • /
    • 2002
  • A common YBCO powder has been made from a mixture of Y123 and Y211 that heated at different temperatures, respectively. The synthesis temperature of Y211 is lower than Y123. If Y211 has been heated as a synthesis temperature of Y123, a particle size of it may be very coarse. It exist as one of main defects for superconductor. But We simultaneously synthesize a YBCO(its composition is (Y123+0.4Y211)+$lwt%CeO_2$) using polymeric complex method. In the YBCO, the Y123 is synthesized lower temperature than other methodes, and its crystal structure is orthorombic. For measurement of these superconducting properties, we fabricated a YBCO single crystal. The manufactured YBCO single crystal is measured a magnetic distribution device using 0.5Tesla magnet and trapped magnet fields in it are 0.2Tesla.

  • PDF