• Title/Summary/Keyword: Transmitted light

Search Result 295, Processing Time 0.029 seconds

Characterization of Sheet Formation by Image Analysis (화상분석 시스템을 이용한 지필도 평가)

  • 원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.30-40
    • /
    • 1999
  • The possibility of the characterization of sheet formation by image analysis with transmitted light was evaluated. Specific perimenter, average perimeter and variation could not be used to predict the sheet formation because there were no corrleation. Although image analysis method still have a lot of problems , it was found that the contrast intensity obtained by image analysis with transmitted light can be used to predict the sheet formation. In the case of highly filled sheet, the intensity of transmitted light was too low to characterize the sheet formation . However, it was possible to characterize the formation of unfilled heavy weight paper($\leq$200g/㎡).

  • PDF

A Study on Discrimination of Watercore Apple using Transmitted Light and Effects of various Factors (투과광을 이용한 밀병 사과의 판별 가능성 및 영향인자 조사)

  • 손미령;정경원;조래광
    • Food Science and Preservation
    • /
    • v.7 no.4
    • /
    • pp.357-361
    • /
    • 2000
  • Watercore influences storage and distribution industry of fruit. Therefore, the technique for nondestructive discrimination of watercore fruit is needed. This work reports about the possibility of watercore discrimination of ante using transmitted light, and the effects of various factors. CCD camera was used to capone images of each apple fruit. An excess watercore apples were higher light transmission score than little watercore apples. The accuracy fur discrimination of watercore apple was about 70% using transmitted light. Peel thickness, anthocyanin layer thickness and density of apple affected the light transmission. Apples having thin peel, thin pigment layer and low density tended to high transmitted light score. Apples of good color degree were more probability of existence watercore than ones of bad color degree. But color distribution of apple peel was not correlated with watercore.

  • PDF

Illumination Control in Visible Light Communication Using Manchester Code with Sync-Mark Signal

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.149-155
    • /
    • 2020
  • In this study, we employed Manchester code for illumination control and flicker prevention of the light-emitting diode (LED) used in a visible light communication (VLC) system. In the VLC transmitter, the duty factor of the Manchester code was utilized for illumination control; in the VLC receiver, the spike signal from an RC-high pass filter was utilized to recover the transmitted signal whilst suppressing the 120-Hz noise arising from adjacent lighting lamps. Instead of the clock being transmitted in a separate channel, a syncmark signal was transmitted in front of each data byte and used as the reference time for transforming the Manchester code to non-return-to-zero (NRZ) data in the receiver. In experiments, the LED illumination was controlled in the range of approximately 12-84% of the constant wave (CW) light via changing of the duty factor from 10% to 90%. This scheme is useful for constructing indoor wireless sensor networks using LED light that is flicker-free and presents capability for illumination control.

Development of Light Transmission Fluctuation for Particle Measurement in Solid-Gas Two Phase Flows

  • YANG, Bin;WANG, Zhan-ping;HE, Yuan;CAI, Xiao-Shu
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • In order to realize In-line and convenient measurement for solid-gas two phase flows, Light Transmission Fluctuation (LTF) based on the random variation of transmitted light intensity, light scattering theory and cross-correlation method was presented for online measurement of particle size, concentration and velocity. The statistical relationship among transmitted light intensity, particle size and particle number in measurement zone was described by Beer-Lambert Law. Accordingly, the particle size and concentration were determined from the fluctuation signal of transmitted light intensity. Simultaneously, the particle velocity was calculated by cross-correlation analysis of two neighboring light beams. By considering the influence of concentration variation in industrial applications, the improved algorithm based on spectral analysis of transmitted light intensity was proposed to improve measurement accuracy and stability. Therefore, the online measurement system based on LTF was developed and applied to measure pulverized coal in power station and raw material in cement plant. The particle size, concentration and velocity of powder were monitored in real-time. It can provide important references for optimal control, energy saving and emission reduction of energy-intensive industries.

Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system

  • Shin, S.;Park, M.S.;Jang, J.H.;Ky, Y.H.;Suh, J.S.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.3
    • /
    • pp.129-134
    • /
    • 2004
  • The aggregation characteristics of red blood cells (RBCs) were measured using a newly developed light-transmission slit rheometer. Conventional methods of RBC disaggregation such as the rotational Couette system were replaced with a pressure-driven slit flow system with a vibrational mechanism. Using a vibration generator, one can disaggregate the RBC aggregates stored in the slit. While shear stress decreases exponentially, instantaneous pressure and the transmitted light intensity were measured over time. Applying an abrupt shearing flow after disaggregation caused a rapid elongation of the RBCs followed by loss of elongation with the decreasing shear stress. While the shear stress is further decreasing, the RBCs start to re-aggregate and the corresponding transmitted intensity increases with time, from which the aggregation indices can be obtained using a curve-fitting program.

CONTROL OF POLARIZATION OF LIGHT TRANSMITTED AND REFELECTED BY ANISOTROPIC SUBSTRATES WITH MICRORELIEF

  • Belyaev, V.V.;Kushnir, E.M.;Kalashnikov, A.Y.;Klyckov, A.V.;Tsoy, V.I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1251-1253
    • /
    • 2004
  • Light diffraction on optically anisotropic substrates with the surface microrelief has been calculated by using the OAGSM method. Varying of the microrelief depth and material birefringence allows to realize different polarization state of the light beam transmitted or reflected by the substrate. The approach can be used to optimize the LCD backlight.

  • PDF

Effects of Eggshell Pigmentation and Egg Size on the Spectral Properties and Characteristics of Eggshell of Meat and Layer Breeder Eggs

  • Shafey, T.M.;Al-mohsen, T.H.;Al-sobayel, A.A.;Al-hassan, M.J.;Ghnnam, M.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.2
    • /
    • pp.297-302
    • /
    • 2002
  • The effects of eggshell pigmentation and egg size (medium and large) on the spectral properties and characteristics of eggshells were examined in eggs from two genetic groups of breeder flocks. Birds from meat (Hybro, pigmented eggshell, PES) and layer (Leghorn, non-pigmented eggshell, NPES) at 40 and 46 weeks of age, respectively, were used. Measurements of per cent shell (PS), shell thickness (ST), shell volume (SV), shell density (SD), egg shell conductance (EC) and physical dimensions of eggs were made. The spectral properties of eggshells were measured over the wavelength (WL) range of 200 to 1,100 nm. Eggshell absorbed approximately 99.8 percent of the light and transmitted only about 0.12 percent with a maximum light transmission at the near-infra-red region of about 1075 nm. It attenuated shorter WL and transmitted longer WL. Eggshell pigmentation and egg size influenced light transmission into the egg. The NPES had higher EC and transmission of light and lower PS and SD than those of the PES. Large size eggs had higher EC, SD, SV, transmission of light and egg physical dimensions than those of medium size eggs. It is concluded that genetic make up of birds and egg size influenced eggshell characteristics including EC and that, as a consequence, the difference in the spectral properties of eggshells. The pigmentation of eggshell influenced the amount and WL transmitted into the egg. The size and EC of eggs influenced the amount of light transmitted through the eggshell. EC is a good indicator for the ability of eggshell to transmit light.

An Experimental Study on the Light Transmission Characteristics with Oil Contamination (윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.

Flicker Prevention Through Edge-Pulse Modulation in a Visible Light Identification System (가시광 무선인식장치에서 가장자리 펄스변조를 이용한 플리커 방지)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.180-186
    • /
    • 2020
  • In this study, we applied edge-pulse modulation to prevent the flicker of light-emitting diode (LED) light in a visible light identification system. In the visible light transmitter, positive pulses were transmitted at the edges of the low-to-high transition points, and negative pulses were transmitted at the edges of the high-to-low transition points of the non-return-to-zero (NRZ) data waveforms. In the visible light receiver, the NRZ waveforms were regenerated by making low-to-high and high-to-low transitions at the point of the positive and negative pulses, respectively. This method has two advantages. First, it ensures that the LED light is flicker-free because the average optical power of the LED was kept constant during data transmission in the transmitter. Second, the 120 Hz optical noise from the adjacent lighting lamps was easily cut off using a simple RC-high pass filter in the receiver.

An Experimental Study on the Light Transmission Characteristics with Oil Contamination (윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.287-298
    • /
    • 2001
  • Change in light transmission characteristics caused by various types of oil contaminations was experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon dust, two kinds of solutions and grease were used for the lest contaminants in this work. Light intensity of the transmitted light was treasured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and polymeric fibers mainly due to the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change iii lubricating oils.

  • PDF