• Title/Summary/Keyword: Transmission system

Search Result 9,113, Processing Time 0.041 seconds

BER performance analysis of successive interference cancellation(SIC) algorithm for W-CDMA HSDPA receiver (W-CDMA HSDPA수신기의 직렬간섭제거 알고리즘의 오류율 성능해석)

  • Koo Je-Gil
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.1
    • /
    • pp.13-22
    • /
    • 2004
  • This paper drives the exact expression of bit error rate(BER) performance for successive interference cancellation(SIC) algorithm against multipath interference components in a high-speed downlink packet access(HSDPA) system of W-CDMA downlink and the BER performance is evaluated by numerical analysis. Numerical results showed that the average BER performance is rapidly saturated in terms of increasing the number of multipath and is revealed significant improvement for improvement Processing gain(PG). For example, the average BER Performance of the SIC algorithm is superior to the performance of conventional scheme by more than 7dB and 1.4dB for processing gain PG=54 and 128 under the two-path channel and average BER=$1.0{\times}10^{-3}$, respectively. This results also indicated that the average BER saturation is occurred at nearly one weight factor which is assigned to pilot and data channels. Likewise, the average BER performance is greatly degraded due to increasing the interference power in proportional to the number of multipath with increasing multicode K. And the smaller multipath fading channel gain is arrived later, the more the average BER performance is improved. The results of performance analysis in this paper indicated that the multipath interference cancellation is required to improve the BER performance in a HSDPA system under multicode for high-speed packet transmission, low spreading factor, and multipath fading channel.

User Profile Based Seamless Framework under HTTP Adaptive Streaming Environment (HTTP Streaming 환경에서 User Profile 기반 Seamless Framework 제공방법)

  • Kim, Jung-Han;Lee, Jang-Won;Kim, Kyu-Heon;Suh, Doug-Young
    • Journal of Broadcast Engineering
    • /
    • v.16 no.1
    • /
    • pp.155-173
    • /
    • 2011
  • Recently, with the digitalization of a broadcasting system and the development of a communication technology, the existing trend of consuming media contents throughout the fixed-displayer and the dedicated channel is being changed. The existing user only could consume media contents under limited time and places because of the fixed-displayer and the dedicated channel. However, with advent of the IP-based terminals and HTTP adaptive streaming which transfer the media sequence according to the user's transmission condition, users become possible to enjoy the media content anytime anywhere. As the result of the alteration of the broadcasting surrounding, users can enjoy the media content while changing his terminals according to their preferences and circumstances. However, in case that users try to consume consecutively the content from last view-point ended in the previous terminal under current HTTP adaptive streaming environment, a user has to remember the last view-point, and then has to apply the view-point to the changed terminal. Thus, for solving this problem, this paper defines "User Profile" for describing the metadata for the chained content consume environment between the terminals. Also, for proving the proposed method, this paper try to demonstrate the proposed method throughout the realization of the system based on Smooth Streaming from Microsoft.

Measurement of Vertical-Directional DTV Signal Level Using a Multi-Copter (멀티콥터를 이용한 수직방향 DTV 신호 레벨 측정)

  • Park, Hyung-Do;Lim, Sol;Kim, Dae Jin
    • Journal of Broadcast Engineering
    • /
    • v.19 no.3
    • /
    • pp.372-384
    • /
    • 2014
  • DTV field tests have been performed to measure field strength and to check reception ratio on indoor and outdoor sites. They use an antenna of 9m to measure DTV signal in case of outdoor measurement on the road. Modern skyscrapers require the analysis of vertical-directional wave propagation by measuring vertical-directional DTV signal. Even if the field strength is above the reception threshold of $43dB{\mu}V/m$, the reception is impossible in case of strong multi-path or high impulse noise. So, vertical-directional field measurement is essential in environment of tall buildings. In this paper, we developed an octo type multi-copter to measure vertical-directional DTV signal level. A compact and portable DTV signal level meter, an antenna, a microwave transmitter for data transmission, and a recording equipment are equipped in the multi-copter. Three different sites are selected to test the measurement system. Developed measurement system using the multi-copter is very useful in measuring vertical-directional DTV signal, especially in apartments, non-accessible area by vehicles, and forbidden areas.

Adaptive Range Aggregation Index Method for Efficient Spatial Range Query in Ubiquitous Sensor Networks (USN환경에서 효율적인 공간영역질의를 위한 적응형 영역 집계 인덱스 기법)

  • Li, Yan;Eo, Sang-Hun;Cho, Sook-Kyoung;Lee, Soon-Jo;Bae, Hae-Yeong
    • Journal of Korea Spatial Information System Society
    • /
    • v.9 no.2
    • /
    • pp.93-107
    • /
    • 2007
  • In this paper, an adaptive range aggregation spatial index method is proposed for spatial range query in ubiquitous sensor networks. As the ubiquitous sensor networks are the new information-oriented paradigm, many energy efficient spatial range query methods in ubiquitous sensor networks environment are studied vigorously. In sensor networks, users can monitor environment scalar data such as temperature and humidity during user defined time and spatial ranges. In order to execute spatial range query efficiently, rectangle based index methods are proposed, such as SPIX. But they define the return path as the opposite of its query transmit path. However, the sensor nodes in queried ranges are closed to each other, they can't aggregate the sensed value in a queried range because their query transmission paths are different. As a result, the previous methods waste energy unnecessarily to aggregate sensing data out of the queried range. In this paper, an adaptive aggregation index method is proposed that can aggregate values in a user defined range adaptively by using its neighbor information. It is shown that sensor power is saved efficiently by using the proposed method over the performance evaluation.

  • PDF

An Input/Output Technology for 3-Dimensional Moving Image Processing (3차원 동영상 정보처리용 영상 입출력 기술)

  • Son, Jung-Young;Chun, You-Seek
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.1-11
    • /
    • 1998
  • One of the desired features for the realizations of high quality Information and Telecommunication services in future is "the Sensation of Reality". This will be achieved only with the visual communication based on the 3- dimensional (3-D) moving images. The main difficulties in realizing 3-D moving image communication are that there is no developed data transmission technology for the hugh amount of data involved in 3-D images and no established technologies for 3-D image recording and displaying in real time. The currently known stereoscopic imaging technologies can only present depth, no moving parallax, so they are not effective in creating the sensation of the reality without taking eye glasses. The more effective 3-D imaging technologies for achieving the sensation of reality are those based on the multiview 3-D images which provides the object image changes as the eyes move to different directions. In this paper, a multiview 3-D imaging system composed of 8 CCD cameras in a case, a RGB(Red, Green, Blue) beam projector, and a holographic screen is introduced. In this system, the 8 view images are recorded by the 8 CCD cameras and the images are transmitted to the beam projector in sequence by a signal converter. This signal converter converts each camera signal into 3 different color signals, i.e., RGB signals, combines each color signal from the 8 cameras into a serial signal train by multiplexing and drives the corresponding color channel of the beam projector to 480Hz frame rate. The beam projector projects images to the holographic screen through a LCD shutter. The LCD shutter consists of 8 LCD strips. The image of each LCD strip, created by the holographic screen, forms as sub-viewing zone. Since the ON period and sequence of the LCD strips are synchronized with those of the camera image sampling adn the beam projector image projection, the multiview 3-D moving images are viewed at the viewing zone.

  • PDF

Continued image Sending in DICOM of usefulness Cosideration in Angiography (혈관조영술에서 동영상 전송의 유용성 고찰)

  • Park, Young-Sung;Lee, Jong-Woong;Jung, Hee-Dong;Kim, Jae-Yeul;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.39-43
    • /
    • 2007
  • In angiography, the global standard agreements of DICOM is lossless. But it brings on overload and takes too much store space in DICOM sever. Because of all those things we transmit images which is classified in subjective way. But this cause data loss and would be lead doctors to make wrong reading. As a result of that we try to transmit continued image (raw data) to reduce those mistakes. We got angiography images from the equipment(Allura FD20-Philips). And compressed it in two different methods(lossless & lossy fair). and then transmitted them to PACS system. We compared the quality of QC phantom images that are compressed by different compress method and compared spatial resolution of each images after CD copy. Then compared each Image's data volume(lossless & lossy fair). We measured spatial resolution of each image. All of them had indicated 401p/mm. We measured spatial resolution of each image after CD copy. We got also same conclusion (401p/mm). The volume of continued image (raw data) was 127.8MB(360.5 sheets on average) compressed in lossless and 29.5MB(360.5 sheets) compressed in lossy fair. In case of classified image, it was 47.35MB(133.7 sheets) in lossless and 4.5MB(133.7 sheets) in lossy fair. In case of angiography the diagnosis is based on continued image(raw data). But we transmit classified image. Because transmitting continued image causes some problems in PACS system especially transmission and store field. We transmit classified image compressed in lossless But it is subjective and would be different depend on radiologist. therefore it would make doctors do wrong reading when patients transfer another hospital. So we suggest that transmit continued image(raw data) compressed in lossy fair. It reduces about 60% of data volume compared with classified image. And the image quality is same after CD copy.

  • PDF

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

The properties of Al-doped ZnO films deposited with RF magnetron sputtering system in various H2/(Ar + H2) gas ratios (RF 마그네트론 스퍼터링 방법을 사용해 증착된 Al이 도핑 된 ZnO 박막의 H2/(Ar + H2) 가스 비율에 따른 특성)

  • Kim, Jwa-Yeon;Han, Jung-Su
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.3
    • /
    • pp.122-126
    • /
    • 2012
  • The properties of Al-doped ZnO (AZO) films were investigated as a function of $H_2/(Ar+H_2)$ gas ratio using an AZO (2 wt% $Al_2O_3$) ceramic target in a radio frequency (RF) magnetron sputtering system. The deposition process was done at $200^{\circ}C$ and in $2{\times}10^{-2}$ Torr working pressure and with various ratios of $H_2/(Ar+H_2)$ gas. During the AZO film deposition process, partial $H_2$ gas affected the AZO film characteristics. The electron resistivity (${\sim}9.21{\times}10^{-4}\;{\Omega}cm$) was lowest and mobility (${\sim}17.8\;cm^2/Vs$) was highest in AZO films when the $H_2/(Ar+H_2)$ gas ratio was 2.5 %. When the $H_2/(Ar+H_2)$ gas ratio was increased above 2.5 %, the electron resistivity increased and mobility decreased with increasing $H_2/(Ar+H_2)$ gas ratio in AZO films. The carrier concentration increased with increasing $H_2/(Ar+H_2)$ gas ratio from 0 % to 7.5 %. This phenomenon was explained by reaction of hydrogen and oxygen and additional formation of oxygen vacancy. The average optical transmission in the visible light wavelength region over 90 % and an orientation of the deposition was [002] orientation for AZO films grown with all $H_2/(Ar+H_2)$ gas ratios.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

A Study on Design of Optimal Location for Renewable Energy Facility Using GIS (GIS를 사용한 재생에너지설비 최적 위치 설계에 관한 연구)

  • Jung, Moon-Seon;Moon, Chae-Joo;Chang, Young-Hak;Kim, Young-Gon;Lee, Sook-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.357-368
    • /
    • 2018
  • For well over 100 years, oil has enabled remote communities to generate electricity and enjoy the benefits of a consistent electrical supply. Relying solely on oil for electricity generation has left island and remote communities exposed to several risks and drawbacks. Oil-based electricity generation is often more expensive and subject to price volatility, which can result in the use of risky fuel hedging strategies. The residents of islands and remote communities express concern over the future impacts of climate change or insist on their opinions for the corresponding action with reduction of carbon emissions. These risks and drawbacks can be overcomed with continuing cost reductions in solar, wind, and energy storage technologies by maker. Reducing costs is not always a straightforward process, relying on more diversely and renewably arranged renewable energy sources led to reduced local construction cost in every situation reviewed in this study. In this paper, a convenient and simple design solution which will facilitate the optimum location and transmission route of renewable energy facility using GIS(Geographic Information System) is proposed. The suggested solutions exercised to the case of geomoon island using GIS and identified by local site survey.