무선 전송을 위한 SDH 네트워크 연동장치 설계 (SDH network conversion system design for wireless transmission)

  • 박창수;김종현;유지호;윤병수;김수환;변현규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.461-463
    • /
    • 2018
  • 본 논문에서는 동기식 광 네트워크 SDH(Synchronous Digital Hierarchy)망의 장거리 무선 전송을 위해 필요한 연동 장치를 연구하였다. SDH 방식의 기본 전송단위인 STM-1 신호와 155Mbps급 Synchronous Etherenet의 무선 전송 구현 및 측정 방법을 제안한다. STM-1 전송과 Synchronous Ethernet 전송을 위해 클럭 동기 회복 기능을 제공하며, 안정적인 동기 확보를 위해 예비 클럭 전환 기능을 설계 하였다.

  • PDF

Two case studies on structural analysis of transmission towers under downburst

  • Yang, FengLi;Zhang, HongJie
    • Wind and Structures
    • /
    • 제22권6호
    • /
    • pp.685-701
    • /
    • 2016
  • Downbursts are of great harm to transmission lines and many towers can even be destroyed. The downburst wind field model by Chen and Letchford was applied, and the wind loads of two typical transmission towers in inland areas and littoral areas were calculated separately. Spatial finite element models of the transmission towers were established by elastic beam and link elements. The wind loads as well as the dead loads of conductors and insulators were simplified and applied on the suspension points by concentrated form. Structural analysis on two typical transmission towers under normal wind and downburst was completed. The bearing characteristics and the failure modes of the transmission towers under downburst were determined. The failure state of tower members can be judged by the calculated stress ratios. It shows that stress states of the tower members were mainly controlled by 45 degree wind load. For the inland areas with low deign wind velocity, though the structural height is not in the highest wind velocity zone of downburst, the wind load under downburst is much higher than that under normal wind. The main members above the transverse separator of the legs will be firstly destroyed. For the littoral areas with high deign wind velocity, the wind load under downburst is lower than under normal wind. Transmission towers are not controlled by the wind loads from downbursts in design process.

지게차 변속제어 알고리즘 검증을 위한 임베디드 변속기 시뮬레이터 개발 (Development of Embedded Transmission Simulator for the Verification of Forklift Shift Control Algorithm)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권4호
    • /
    • pp.17-26
    • /
    • 2023
  • A forklift is an industrial vehicle that lifts or transports heavy objects using a hydraulically operated fork, and is equipped with an automatic transmission for the convenience of repetitive transportation, loading, and unloading work. The Transmission Control Unit (TCU) is a key component in charge of the shift control function of an automatic transmission. It consists of an electric circuit with an input/output signal interface function and firmware running on a microcontroller. To develop TCU firmware, the development process of shifting algorithm design, firmware programming, verification test, and performance improvement must be repeated. A simulator is a device that simulates a mechanical system having dynamic characteristics in real time and simulates various sensor signals installed in the system. The embedded transmission simulator is a simulator that is embedded in the TCU firmware. information related to the mechanical system that is necessary for TCU normal operation. In this study, an embedded transmission simulator applied to the originally developed forklift TCU firmware was designed and used to verify various forklift shift control algorithms.

버퍼를 가진 다중코드-코드분할다중접속(MC-CDMA) 시스템에서 동적 전송 제어 프로토콜 설계 (Dynamic Transmission Control Design in Buffered MC-CDMA System)

  • 김영용
    • 대한전자공학회논문지TC
    • /
    • 제39권9호
    • /
    • pp.20-27
    • /
    • 2002
  • 무선 통신망에서의 멀티미디어 전송에 대한 요구는 빠른 속도로 증가하고 있다. 지금까지 CDMA에서의 시스템 분석은 패킷의 재전송을 위한 버퍼가 없는 음성을 위주로 이루어져 왔으나 본 논문에서는 버퍼링과 재전송을 고려한 다양한 QoS 요구조건을 만족할 수 있는 멀티미디어 접속 프로토콜을 제안하고 분석하였다. 먼저 다양한 전송률을 사용할 수 있는 MC-CDMA(Multi-Code CDMA) 전송방식 위에서 버퍼링의 영향을 살펴 보고 다양한 조건에서의 동적 전송률 제어 방식을 제안하고 시뮬레이션을 통해 제시한 방법의 타당성을 검증하였다.

가공 송전 철탑기초 설계 및 시공 방법 연구 - 심형기초를 중심으로 - (A Study on the Transmission Tower Foundation Design and Construction Method - A Focus of Cylindrical Foundation -)

  • 장석한;김희광;이강현;한경수;함방욱;정기선
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1031-1034
    • /
    • 2007
  • Electric transmission lines pass through a variety of area. Foundation supporting the conductors and tower are selected properly in accordance with external load, for example dead load, wind load, snow load, construction load etc, and topography and geology condition. Typical types of foundation are as follows: pad foundation for small load and hard soil or rock in mountainous area, pile foundation for medium or large load and soft soil in plain field area. This paper introduced cylindrical foundation design & construction for large load and mountainous area. This foundation failure mode against pulling-out show splitting failure by tensile force toward circumferential direction.

듀얼 모드형 고신뢰 PLC 모뎀 칩 설계 및 구현 (Design and Implementation of the Dual-Mode Type Reliable PLC Modem Chip)

  • 이원태;최성수;윤성하;이영철
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.488-493
    • /
    • 2008
  • This paper represents a dual-mode type transmission technique for a high reliable narrow-band power line communication(PLC) modem, and its design and implementation of a system-on-chip(SoC). The proposed transmission technique is based on a Chirp modulation for the purpose of overcoming time variations of power line channel environments in the narrow-bandwidth of the frequency range of 95-145.5 kHz. The designed modem is fabricated utilizing a mixed 0.18 ${\mu}m$ CMOS technology. Especially, according to the power line channel environments the data transmission rate can be selectively changed into 2.5 kbps and 480 bps. The total hardware complexity of the implemented chip is about 50,000 gates, the power consumption is about 26mW, and the operating frequency is up to 5.12 MHz.

공기압 시스템 제어를 위한 데이터 전송시스템 설계 (Design of A Data Transmission System for Pneumatic System Control)

  • 홍춘표;김동수
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 추계학술대회 학술발표 논문집
    • /
    • pp.413-418
    • /
    • 2000
  • For Pneumatic system control, we need a data transmission system with high speed and high realibility for information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF

Coil-Capacitor Circuit Design of a Transcutaneous Energy Transmission System to Deliver Stable Electric Power

  • Choi, Seong-Wook;Lee, Min-Hyong
    • ETRI Journal
    • /
    • 제30권6호
    • /
    • pp.844-849
    • /
    • 2008
  • A new transcutaneous energy transmission (TET) system was developed for transmitting electrical power to an implanted device, such as an artificial heart in a patient's body. This new design can maintain a stable output voltage independent of the load resistance. The system includes a compensation capacitor to reduce energy loss and increase power transfer efficiency. Experimental results show that the output voltage of the receiving coil changes very little as the load resistance varies from 14.8 ${\Omega}$ to 15 $k{\Omega}$, which corresponds to a change in output power from 0.1 to 97 W.

  • PDF

실내 마이크로파 배전 전송계를 위한 가변전력분배기와 도파관의 결합구조 설계 (Design of Variable Power Distributor and Waveguide Connecting Structure for Wireless Microwave Power Transmission in a Building)

  • 최영규
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1477-1482
    • /
    • 2012
  • This paper deals with a new variable microwave power distributor and a connector between a deck plate and a input power waveguide for indoor microwave wireless power transmission. We design a new type connector built in the 3-stage coaxial line structure, and calculate the return loss of the connector at 2.45GHz. Newly designed connector shows the excellent return loss performance less than -30dB at the operating frequency of 2.45GHz. And we show a power distributor in which the dividing ratio of the power is controlled mechanically by three rotary fins. The distributor can control the dividing power from 4.5% to 58% with the variance of 5% output power. The experimentally tested results of the distributor are good agreement with the simulation within the return loss of 1%.

No Blind Spot: Network Coverage Enhancement Through Joint Cooperation and Frequency Reuse

  • Zhong, Yi;Qiao, Pengcheng;Zhang, Wenyi;Zheng, Fu-chun
    • Journal of Communications and Networks
    • /
    • 제18권5호
    • /
    • pp.773-783
    • /
    • 2016
  • Both coordinated multi-point transmission and frequency reuse are effective approaches to mitigate inter-cell interference and improve network coverage. The motivation of this work is to explore the manner to effectively utilize the spectrum resource by reasonably combining cooperation and frequency reuse. The $Mat{\acute{e}}rn$ cluster process, which is appropriate to model networks with hot spots, is used to model the spatial distribution of base stations. Two cooperative mechanisms, coherent and non-coherent joint transmission (JT), are analyzed and compared. We also evaluate the effect of multiple antennas and imperfect channel state information. The simulation reveals that the proposed approach to combine cooperation and frequency reuse is effective to improve the network coverage for users located at both the center and the boundary of the cooperative region.