• Title/Summary/Keyword: Transmission characteristic

Search Result 997, Processing Time 0.038 seconds

Complex Quadruplet Zero Locations from the Perturbed Values of Cross-Coupled Lumped Element

  • Um, Kee-Hong
    • International journal of advanced smart convergence
    • /
    • v.6 no.4
    • /
    • pp.33-40
    • /
    • 2017
  • In this paper, complex quadruplet zeros of microwave filter systems are investigated. For the cascaded systems the chain matrices are most conveniently used to derive the voltage transfer function of Laplace transform with cascaded two-port subsystems. The convenient relations of transfer function and chain matrix are used in order to find the transmission zeros. Starting from a ladder network, we introduced a crossed-coupled lumped element, in order to show the improved response of bandpass filter. By solving the transmission zero characteristic equation derived from the cascaded subsystems, we found the zeros of filter system with externally cross-coupled lumped elements. With the cross-coupled elements of capacitors, the numerator polynomial of system transfer function is used to locate the quadruplet zeros in complex plane. When the two pairs of double are on the zeros -axis, with the perturbed values of element, we learned that the transition band of lowpass filter is improved. By solving the characteristic equation of cascaded transfer function, we can obtain the zeros of the cross-coupled filter system, as a result of perturbed values on lumped element.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

A New Design Approach for Asymmetric Coupled-Section Marchand Balun

  • Park, Ji An;Cho, Choon Sik;Lee, Jae Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.54-60
    • /
    • 2014
  • A systematic design for asymmetric coupled-section Marchand baluns is presented. Asymmetrically coupled transmission lines in multilayer configuration are exploited for constructing Marchand baluns. Design equations for characteristic impedance and electrical length of asymmetrical coupled transmission lines are derived for establishing a systematic design procedure. Novel Marchand balun based on these design equations is composed of two identical asymmetrical coupled transmission lines. However, contrary to the general conventional design approach where ranges for characteristic impedances of coupled lines are ambiguously capitalized, values for characteristic impedance and length are explicitly expressed. Our approach is fundamentally different from the design method using coupling coefficients where solution for coupling coefficient is inherently restricted. To verify the proposed method, one design example is performed for wideband Marchand balun in multilayer configuration, and is fabricated for verifying the design procedure proposed. Maintaining the return loss more than 10 dB, the bandwidth is measured from 0.43 to 1.0 GHz, where $S_{21}$ and $S_{31}$ show better than -4 dB. The measured phase and amplitude imbalances illustrate 0.5 dB and ${\pm}5^{\circ}$, respectively.

Performance Improved Buffer Management Algorithm for GFR Service (GFR 서비스를 위한 성능 향상된 버퍼관리 알고리즘)

  • Cho Hae-Seong
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.248-254
    • /
    • 2005
  • The existing buffer management scheme is caused by with burstness characteristic of the TCP traffic and with only the transmission which is not loss it provides the smallest transmission rate guarantee where the GFR demands and a fair characteristic. In order to provide a high fair characteristic from the dissertation which it sees with the smallest transmission rate guarantee where the GFR demands it proposed the existing buffer algorithm which applies a Fuzzy mechanism in the existing buffer management technique. The proposed algorithm decides a packet disuse used by three parameters which are composed of tagging information, the buffer usage, and the load of VC. Simulation results shows that the fairness and goodput of the proposed algorithm were excellent where the size of MCR will become larger, from the switch the Double-EPD or the DFBA was visible a similar efficiency even from size change of the buffer. The algorithm which is proposed provides a good throughput and a fair characteristic.

  • PDF

Variable Time Step Simulation and Analysis of Hydraulic Control Systems using Transmission Line Modeling (전달관로 모델링을 이용한 유압제어 시스템의 가변 시간스텝 시뮬레이션 및 해석)

  • Hwang, Un-Gyu;Jo, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.843-850
    • /
    • 2002
  • This paper presents a simulation method using the transmission line modeling to reduce simulation runtime of hydraulic control systems. This method is based on separating the system components each other using the transmission line elements prior to simulation, which leads to divide the simulated system into several subsystems suitable for an even more efficient integration. It can also handle nonlinearities and discontinuities without flag signal when restarting integration. By applying variable integration timestep to parallel hydraulic circuits via parallel processing, it is shown that simulation run-time can be reduced significantly compared with that of Runge Kutta method.

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF

Modeling and simulation on an IR absorbing structure with the cascaded transmission line model (전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험)

  • Park, Seung-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.

A measurement of signal transmission parameters in human muscle (인체 근육에 있어서 신호 전송계수의 계측)

  • Lee, Hyun-Chul;Lee, Seung-Ju;Kim, Ki-Young;Yoon, Chae-Hyun;Yoon, Yang-Woung;Park, Hyung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2699-2701
    • /
    • 2002
  • In this study, a system for measurement of impedance (transmission parameter) on the human muscle was constructed. The system composed of the stimulating part for input with milli-voltage and the measuring part for measurement of transmission voltage in human muscle. As a result of this experiment, the frequency characteristic of each subject represent that the transmission voltage goes up in spite of a constant input voltage according to frequency (1Hz -50kHz) increment. Namely, the amplitude of input signal was not reflected but frequency was reflected on the measured results. This result be estimated that the proposed system is able to measure passive electrical characteristic of human body.

  • PDF

The Effects of ADSL Transmission Speed and Quality with Subscribe-loop characteristic (가입자 선로특성에 따른 ADSL 전송품질에의 영향)

  • 이재완;황민호;서석철;이해길;고남영
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.133-138
    • /
    • 2001
  • The high-speed data service is on the increase and on the development because of using the coaxial cable which hold the most part of subscriber's loop, the transmission rate in a subscriber line has influenced by an external-electromagnetic factor such as the falling of a thunderbolt and the electromagnetic induction on transmission line. this external environment gets the noise of a communications line and then has an influence to the transmission speed and quality for the high-speed data service. this paper makes an analysis of noise characteristic appeared a subscriber communications line, measures a transmission speed per each cable-distance and resolves these relationship by putting the noise, which has affected extensively the transmission quality of ADSL service, into a subscriber line.

  • PDF