• 제목/요약/키워드: Transmission characteristic

검색결과 998건 처리시간 0.029초

Complex Quadruplet Zero Locations from the Perturbed Values of Cross-Coupled Lumped Element

  • Um, Kee-Hong
    • International journal of advanced smart convergence
    • /
    • 제6권4호
    • /
    • pp.33-40
    • /
    • 2017
  • In this paper, complex quadruplet zeros of microwave filter systems are investigated. For the cascaded systems the chain matrices are most conveniently used to derive the voltage transfer function of Laplace transform with cascaded two-port subsystems. The convenient relations of transfer function and chain matrix are used in order to find the transmission zeros. Starting from a ladder network, we introduced a crossed-coupled lumped element, in order to show the improved response of bandpass filter. By solving the transmission zero characteristic equation derived from the cascaded subsystems, we found the zeros of filter system with externally cross-coupled lumped elements. With the cross-coupled elements of capacitors, the numerator polynomial of system transfer function is used to locate the quadruplet zeros in complex plane. When the two pairs of double are on the zeros -axis, with the perturbed values of element, we learned that the transition band of lowpass filter is improved. By solving the characteristic equation of cascaded transfer function, we can obtain the zeros of the cross-coupled filter system, as a result of perturbed values on lumped element.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

A New Design Approach for Asymmetric Coupled-Section Marchand Balun

  • Park, Ji An;Cho, Choon Sik;Lee, Jae Wook
    • Journal of electromagnetic engineering and science
    • /
    • 제14권2호
    • /
    • pp.54-60
    • /
    • 2014
  • A systematic design for asymmetric coupled-section Marchand baluns is presented. Asymmetrically coupled transmission lines in multilayer configuration are exploited for constructing Marchand baluns. Design equations for characteristic impedance and electrical length of asymmetrical coupled transmission lines are derived for establishing a systematic design procedure. Novel Marchand balun based on these design equations is composed of two identical asymmetrical coupled transmission lines. However, contrary to the general conventional design approach where ranges for characteristic impedances of coupled lines are ambiguously capitalized, values for characteristic impedance and length are explicitly expressed. Our approach is fundamentally different from the design method using coupling coefficients where solution for coupling coefficient is inherently restricted. To verify the proposed method, one design example is performed for wideband Marchand balun in multilayer configuration, and is fabricated for verifying the design procedure proposed. Maintaining the return loss more than 10 dB, the bandwidth is measured from 0.43 to 1.0 GHz, where $S_{21}$ and $S_{31}$ show better than -4 dB. The measured phase and amplitude imbalances illustrate 0.5 dB and ${\pm}5^{\circ}$, respectively.

GFR 서비스를 위한 성능 향상된 버퍼관리 알고리즘 (Performance Improved Buffer Management Algorithm for GFR Service)

  • 조해성
    • 한국콘텐츠학회논문지
    • /
    • 제5권5호
    • /
    • pp.248-254
    • /
    • 2005
  • 기존의 버퍼 관리 방법은 TCP 트래픽의 "burstness" 특성으로 인해 손실 없는 전송만으로는 GFR이 요구하는 최소 전송률 보장과 공평성을 제공하기 어렵다. 본 논문에서는 GFR이 요구하는 최소 전송률 보장과 높은 공평성을 제공하기 위하여 기존의 버퍼관리 기법에 퍼지 이론을 적용한 버퍼관리 알고리즘을 제안하였다. 제안된 알고리즘은 태깅정보, 버퍼 점유량, VC의 부하정도로 구성된 세 개의 파라미터를 이용하여 패킷 폐기를 결정한다. 시뮬레이션 결과 MCR의 크기가 커질수록 제안된 알고리즘의 수율과 공평성이 우수하였으며, 스위치에서 버퍼의 크기 변화에서도 Double-EPD나 DFBA는 비슷한 성능을 보였고, 제안된 알고리즘은 좋은 수율과 공평성을 제공한다.

  • PDF

전달관로 모델링을 이용한 유압제어 시스템의 가변 시간스텝 시뮬레이션 및 해석 (Variable Time Step Simulation and Analysis of Hydraulic Control Systems using Transmission Line Modeling)

  • 황운규;조승호
    • 대한기계학회논문집A
    • /
    • 제26권5호
    • /
    • pp.843-850
    • /
    • 2002
  • This paper presents a simulation method using the transmission line modeling to reduce simulation runtime of hydraulic control systems. This method is based on separating the system components each other using the transmission line elements prior to simulation, which leads to divide the simulated system into several subsystems suitable for an even more efficient integration. It can also handle nonlinearities and discontinuities without flag signal when restarting integration. By applying variable integration timestep to parallel hydraulic circuits via parallel processing, it is shown that simulation run-time can be reduced significantly compared with that of Runge Kutta method.

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF

전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험 (Modeling and simulation on an IR absorbing structure with the cascaded transmission line model)

  • 박승만
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.

인체 근육에 있어서 신호 전송계수의 계측 (A measurement of signal transmission parameters in human muscle)

  • 이현철;이승주;김기영;윤재현;윤양웅;박형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2699-2701
    • /
    • 2002
  • In this study, a system for measurement of impedance (transmission parameter) on the human muscle was constructed. The system composed of the stimulating part for input with milli-voltage and the measuring part for measurement of transmission voltage in human muscle. As a result of this experiment, the frequency characteristic of each subject represent that the transmission voltage goes up in spite of a constant input voltage according to frequency (1Hz -50kHz) increment. Namely, the amplitude of input signal was not reflected but frequency was reflected on the measured results. This result be estimated that the proposed system is able to measure passive electrical characteristic of human body.

  • PDF

가입자 선로특성에 따른 ADSL 전송품질에의 영향 (The Effects of ADSL Transmission Speed and Quality with Subscribe-loop characteristic)

  • 이재완;황민호;서석철;이해길;고남영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.133-138
    • /
    • 2001
  • 가입자 Loop 대다수를 차지하는 동선케이블을 이용한 고속데이터서비스가 증가 발전하고 있는데 가입자선로에서 전송속도에 영향을 미치는 요소는 여러 종류가 있지만 전송로상에서 낙뢰, 전력유도 등 외부 전자기적 환경에 의해 통신회선에 잡음이 발생하고 이리한 잡음은 고속데이터서비스의 전송속도 및 전송품질에 영향을 미치게 된다. 된 연구에서는 가입자 통신회선에서 나타나는 잡음특성을 분석하고, 이를 기반으로 ADSL서비스의 전송품질에 가장 광범위하게 영향을 미치는 잡음을 가입자선로에 주입하여 케이블 거리별 전송속도를 측정하고 전송속도와의 관계를 분석하였다.

  • PDF