• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.026 seconds

A study on the thickness correction for symmetrical inductive irises with rounds in rectangular waveguides (구형도파관내의 라운드를 갖는 대칭형 인덕티브 아이리스에 대한 두께 보정에 관한 연구)

  • 유경완;박광량;김재명
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.1-9
    • /
    • 1995
  • The structures of inductive irises are used commonly in waveguide filter, especially at highter frequencyies, due to low loss and high temperature stability. However, the iris thickness can not be neglected, as it could be at the lower frequencies. Approximate models assuming zero thickness fail to predict the exact behavior of the filter. And current thickness correction is introduced which is valid in the case of thick irises only. Account of the effect of round is normally not taken. So the necessity of finding a relation for the two factors-iris thickness and round-arises in the design of waveguide filters. This paper describes a mutual relation that considers the combined effect of finite thickness and round from the start. In order to test the validity of the changed relation, weveral examples are given. And the measured response of each case is then compared with the predicted reponse. And it is shown that the radius is of perceptible influence on the transmission coefficient through a thick iris.

  • PDF

New degradation mechanism of GaAs HBT induced by Hot carriers (핫 캐리어에 의한 GaAs HBT의 새로운 열화 메카니즘)

  • 권재훈;김도현;송정근
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.30-36
    • /
    • 1997
  • AlGaAs/GaAs HBTs are developed well enough to be commercialized as an active device in optical transmission system, but there remains the unanswered questions about reliability. In this paper we applied the reverse constant current stress at the high voltage in avalanche region for a long time to find out a new degradation mechanism of junctrion I-V. The unction off-set voltage at which the current vanishes to zero was shifted to the negative direction of applied bias due to the increment of leakage current as the stress time increases. It was identified that the degradation was induced by the hot carriers which were generated at space charge region and trapped at the interface between GaAs base and the passivation nitride enhancing the electric field across the nesa edge.

  • PDF

Design and Configuration of Reconfigurable ATM Networks with Unreliable Links

  • Lee, Jong-Hyup
    • ETRI Journal
    • /
    • v.21 no.4
    • /
    • pp.9-22
    • /
    • 1999
  • This paper considers a problem of configuring both physical backbone and logical virtual path (VP) networks in a reconfigurable asynchronous transfer mode (ATM) network where links are subject to failures. The objective is to determine jointly the VP assignment, the capacity assignment of physical links and the bandwidth allocation of VPs, and the routing assignment of traffic demand at least cost. The network cost includes backbone link capacity expansion cost and penalty cost for not satisfying the maximum throughput of the traffic due to link failures or insufficient link capacities. The problem is formulated as a zero-one non-linear mixed integer programming problem, for which an effective solution procedure is developed by using a Lagrangean relaxation technique for finding a lower bound and a heuristic method exploited for improving the upper bound of any intermediate solution. The solution procedure is tested for its effectiveness with various numerical examples.

  • PDF

Design of Balanced Dual-Band Bandpass Filter with Self-Feedback Structure

  • Chen, Xinwei;Han, Guorui;Ma, Runbo;Gao, Jiangrui;Zhang, Wenmei
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.475-477
    • /
    • 2009
  • A balanced dual-band bandpass filter based on ${\lambda}$/2 stepped-impedance resonators and open-loop resonators is proposed in this letter. By employing a type of self-feedback structure, an extra transmission zero is introduced near the common-mode resonance frequency, and the common-mode signal is suppressed. The measured results indicate that the filter can operate in 2.46 GHz and 5.6 GHz bands, and the insertion loss is 1.85 dB and 1.9 dB, respectively. Also, better common-mode suppression is achieved.

Electrically controllable polymer-dispersed liquid crystal (전기적 스위칭이 가능한 고분자 분산형 액정 제작 및 동적 홀로그램 기록 특성)

  • 성기영;경천수;이영락;최병철;곽종훈;최옥식;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.494-499
    • /
    • 1999
  • We report on the results of holographic transmission grating that can be controlled by the applied AC electric field. We have fabricated a polymer-dispersed liquid crystal material that composed of multifunctional acrylate monomer blended with the liquid crystal mixture E7. To investigate an electro-optic properties of fabricated HPDLC, diffraction efficienties (DE) are measured as a fuction of applied electric field and density of liquid crystal. Maximum DE of about 70% is obtained about 30 wt% of LC concentration at a zero field. We have also shown that optical image was recorded in the tllm, and then the reconstructive image was switchable with the applied electric fields. ields.

  • PDF

Physical Layer Security in Underlay CCRNs with Fixed Transmit Power

  • Wang, Songqing;Xu, Xiaoming;Yang, Weiwei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.260-279
    • /
    • 2015
  • In this paper, we investigate physical layer security for multiple decode-and-forward (DF) relaying underlay cognitive radio networks (CRNs) with fixed transmit power at the secondary network against passive eavesdropping attacks. We propose a simple relay selection scheme to improve wireless transmission security based on the instantaneous channel information of all legitimate users and the statistical information about the eavesdropper channels. The closed-form expressions of the probability of non-zero secrecy capacity and the secrecy outage probability (SOP) are derived over independent and non-identically distributed Rayleigh fading environments. Furthermore, we conduct the asymptotic analysis to evaluate the secrecy diversity order performance and prove that full diversity is achieved by using the proposed relay selection. Finally, numerical results are presented to verify the theoretical analysis and depict that primary interference constrain has a significant impact on the secure performance and a proper transmit power for the second transmitters is preferred to be energy-efficient and improve the secure performance.

A Study on the development of optical fiber incorporated high-voltage underground power cable (광복합 고압지중전력케이블의 개발에 관한 연구)

  • Ryu, Jae-Kyu;Yoo, Sung-Jong;Jeon, Seung-Ik;Choi, Bong-Nam;Lee, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1828-1830
    • /
    • 1996
  • In this study, We developed the optical fiber incorporated high-voltage underground power cable which is combined optical fibers with conventional high-voltage underground power cable. Optical-Unit that optical fiber is inserted in stainless tube is tested, and we got good results enough to safe optical fibers. Also we put the optical fiber incorporated high-voltage underground power cable to the test of electrical characteristics and optical characteristics, we knew that the electrical characteristics were the same characteristics as conventional high-voltage underground power cable and the transmission loss change was almost zero.

  • PDF

A study on operating properties of superconducting fault current limiter in the line-to-line fault (선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

Simulation for current limiting characteristics of the resistive and inductive SFCL with line-to-ground fault

  • Choi, Hyo-Sang;Hwang, Si-Dole;Kim, Sang-Joon;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.73-80
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of impedance for line-to-ground faults in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $^45{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limits the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppresses the current below 14 kA, but with 5 kA of DC component which decreases to zero in 5 cycles. We concluded that the inductive SFCL has higher performance in current limiting effect, but the resistive SFCL was better from the viewpoint of less DC components.

  • PDF

A new algorithm for power system stability calculations (전력계통안정도 계산앨고리즘의 개선에 관한 연구)

  • 박영문
    • 전기의세계
    • /
    • v.29 no.3
    • /
    • pp.193-200
    • /
    • 1980
  • A new algorithm for power system stability calculations is developed which considers the nonlinear state equations of 8 state variables for each generator dynamics, expollential load models in respect to bus voltages for nonlinear loads, network equations expressed in terms of bus-injected current sources, various kinds of generator and transmission line outages, abrupt changes in loads, and operations of various kinds of portective relaying systems such as distance relaying, reclosing load shedding by under-frequency relays. In the algorithm are included efficient and reliable schemes for solving network equations by means of the Newton-Raphson iterative method and the Optimally-Ordered Triangular Factorization Technique, and simple procedures for determining fault-point negative and zero sequence impedances for unbalanced line faults. An application of the Optimally-Ordered Triangular Factorization Techniques results in remarkable savings in computing time and memory requirements.

  • PDF