• 제목/요약/키워드: Transmission Source

검색결과 1,257건 처리시간 0.026초

Clamping-diode Circuit for Marine Controlled-source Electromagnetic Transmitters

  • Song, Hongxi;Zhang, Yiming;Gao, Junxia;Zhang, Yu;Feng, Xinyue
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.395-406
    • /
    • 2018
  • Marine controlled-source electromagnetic transmitters (MCSETs) are important in marine electromagnetic exploration systems. They play a crucial role in the exploration of solid mineral resources, marine oil, and gas and in marine engineering evaluation. A DC-DC controlled-source circuit is typically used in traditional MCSETs, but using this circuit in MCSETs causes several problems, such as large voltage ringing of the high-frequency diode, heating of the insulated-gate bipolar transistor (IGBT) module, high temperature of the high-frequency transformer, loss of the duty cycle, and low transmission efficiency of the controlled-source circuit. This paper presents a clamping-diode circuit for MCSET (CDC-MCSET). Clamping diodes are added to the controlled-source circuit to reduce the loss of the duty ratio and the voltage peak of the high-frequency diode. The temperature of the high-frequency diode, IGBT module, and transformer is decreased, and the service life of these devices is prolonged. The power transmission efficiency of the controlled-source circuit is also improved. Saber simulation and a 20 KW MCSET are used to verify the correctness and effectiveness of the proposed CDC-MCSET.

이동 애드혹 네트워크에서 신뢰성 향상을 위한 액티브 기반연구 (The Study Active-based for Improvement of Reliablity In Mobile Ad-hoc Network)

  • 박경배;강경인;유재휘;김진용
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.188-198
    • /
    • 2002
  • 본 논문에서는 이동 애드혹 네트워크에서 신뢰성 향상을 위한 액티브 네트워크를 제안하였다. 제안된 알고리즘에서는 DSR을 기본 프로토콜로서 액티브네트워크를 구성하였고, 송수신 노드를 액티브 노드로서 이용하였다. 신뢰성 향상을 위해 송신노드는 최근 보낸 데이터를 저장할 임시 버퍼를 생성한 후 수신노드의 요구에 의해 데이터 재전송을 수행하며 수신노드 당 흐름관리를 할 수 있는 기능을 추가하여 송신 액티브노드로 기능을 변경하였다. 수신노드는 손실된 데이터에 대한 재 전송요구와 흐름제어 기능을 추가하는 수신 액티브노드로 기능을 변경하였다. 그 결과로서, 제안된 액티브 노드는 움직임이 적은 이동 애드혹 네트워크에서는 100[%]에 근접하는 신뢰성을 보였고, 움직임이 많은 이동 애드혹 네트워크에서 보다 평균 3.5737% 증가한 95%의 데이터 수신율을 보장하였다.

  • PDF

건설장비 캐빈 저소음화를 위한 시험적 연구 (Experimental Study for Construction Equipment's Cabin Noise Control)

  • 이태경;주원호;배종국
    • 한국소음진동공학회논문집
    • /
    • 제19권8호
    • /
    • pp.802-808
    • /
    • 2009
  • In this paper, the experimental study on the identification of noise sources and noise transmission paths was carried out for the cabin noise control of construction equipment. In order to investigate noise and vibration characteristics of cabin structure, sound absorption, transmission, and radiation tests were performed using cabin assembly models. The noise/vibration source levels were obtained from the real cabins of wheel loader and excavator. Using transfer functions of cabins and real cabins' source data, cabin noise was decomposed into airborne and structureborne noise transmissions. Finally noise sources and major transmission paths were successfully identified for wheel loader and excavator's cabins.

건설장비 캐빈 저소음화를 위한 시험적 연구 (Experimental Study for Construction Equipment's Cabin Noise Control)

  • 이태경;주원호;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.84-89
    • /
    • 2009
  • In this paper, the experimental study on the identification of noise sources and noise transmission paths was carried out for the cabin noise control of construction equipment. In order to investigate noise and vibration characteristics of cabin structure, sound absorption, transmission, and radiation tests were performed using cabin assembly models. The noise/vibration source levels were obtained from the real cabins of wheel loader and excavator. Using transfer functions of cabins and real cabins' source data, cabin noise was decomposed into airborne and structureborne noise transmissions. Finally noise sources and major transmission paths were successfully identified for wheel loader and excavator's cabins.

  • PDF

1.25 Gb/s Broadcast Signal Transmission in WDM-PON Based on Mutually Injected Fabry-Perot Laser Diodes

  • Yoo, Sang-Hwa;Mun, Sil-Gu;Kim, Joon-Young;Lee, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.101-106
    • /
    • 2012
  • We demonstrate a cost effective broadcast signal transmission at 1.25-Gb/s with 100 GHz channel spacing based on a broadband light source (BLS) for a wavelength division multiplexing-passive optical network (WDM-PON). The BLS is implemented by using mutually injected Fabry-Perot laser diodes (MI F-P LDs). The error-free transmission without a forward error correction (FEC) is achieved by its low relative intensity noise (RIN). The number of usable modes is determined by RIN and/or extinction ratio (ER) in the spectrum sliced light output.

An Experimental Study on Multiple ICP & Helicon Source for Oxidation in Semiconductor Process

  • Lee, Jin-Won;Na, Byoung-Keun;An, Sang-Hyuk;Chang, Hong-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.271-271
    • /
    • 2012
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance, Inductively Coupled Plasma, Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. In this presentation, we will propose the new concept of the multiple source, which consists of a parallel connection of ICP sources and helicon plasma sources. For plasma uniformity, equivalent power (especially, equivalent current in ICP & Helicon) should distribute on each source. We design power feeding line as coaxial transmission line with same length of ground line in each source for equivalent power distribution. And we confirm the equivalent power distribution with simulation and experimental result. Based on basic study, we develop the plasma source for oxidation in semiconductor process. we will discuss the relationship between the processing parameters (With or WithOut magnet, operating pressure, input power ). In ICP, plasma density uniformity is uniform. In ICP with magnet (or Helicon) plasma density is not uniform. As a result, new design (magnet arrangement and gas distributor and etc..) are needed for uniform plasma density in ICP with magnet and Helicon.

  • PDF

소형 잔향실을 이용한 동력 분산형 고속철도 차량의 투과손실 측정 (Transmission Loss Estimation of HST using a Small Scale Reverberation Chamber)

  • 김태민;손창훈;김정태;김정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.302-307
    • /
    • 2010
  • Development of light-weight high speed train (HST) based on distributed motor control with the top speed of 350 km/hr has engendered a need for abatement of the interior noise of the train cabin. The development of noise abatement measures is crucial at the design stage of the train car since the noise transmission characteristics of the car structure directly influences the cabin interior noise. Since the transmission loss measurement using the entire car structure is often not feasible, especially at the initial stages of the train development, investigation of transmission characteristics using small-scale reverberation chamber can furnish useful alternative source of predicting the noise level. In the present study, white noise is generated at source and transmission loss estimated by performing measurement of a specimen in a scaled reverberation chamber. Comparison of measured values with the previously derived numerical values show good agreement in the overall trend but appreciable quantitative differences still remain.

  • PDF

트랙터 운전실의 소음 저감에 관한 연구 (Noise Reduction in Tractor Cabin)

  • 김원진;은명우
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.380-384
    • /
    • 2014
  • This study focused on identifying the major noise source in a tractor cabin using experimental methods. The noise levels in a tractor cabin for different engine revolution speeds were analyzed to identify the noise source. The results showed that the power steering unit (PSU) was the major noise source in a tractor cabin. The PSU was moved to the outside from the inside of the cabin in order to reduce the noise in the tractor cabin. As a result, the noise levels on the left and right sides of the operator in the tractor cabin were reduced by 6.8 and 3.9 dB, respectively. Finally, the window method was introduced to evaluate the contribution of the transmission noise. The orders of significance in the tractor noise were the front, bottom, and left area, successively.

Adaptive Decode-and-Forward Cooperative Networks with Multiple Relay Nodes

  • Vu, Ha Nguyen;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제11권1호
    • /
    • pp.5-10
    • /
    • 2011
  • We propose an adaptive cooperative scheme with a multi-relay node that achieves high bandwidth efficiency and achieves better SEP performance. In the proposed protocol, if the quality of the direct channel is better than that of the all channels from relays to destination, the source will transmit directly to the destination. Otherwise, the source broadcasts the signal and then a potential relay will be chosen to help the source. A re-transmission will also occur if the potential relay cannot be detected. The spectral efficiency is first derived by calculating the probability of each mode, i.e., direct and cooperation transmission. Subsequently, the SEP performance of M-PSK modulation for the scheme is analyzed by considering each event where the source transmits data to the destination. Finally, the obtained analytical results are verified through computer simulations.

전압원인버터방식 송전용 무효전력보상기의 제어시스템 설계 (Control System Design for Self-Commutated Static Var Compensator)

  • 한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.89-92
    • /
    • 1996
  • This paper describes a detailed simulation model of the static condenser (STATCON) to analyze the dynamic interaction with the ac transmission line. The static condenser was represented by a 12-pulse voltage-source inverter sharing an energy storage dc capacitor. The voltage-source inverter consists of two 6-pulse bridges modeled with ideal gate-turn-off switches. The control system for the static condenser was designed through a mathematical model deduced from the equivalent circuit. Simulation results show that the conceived model is very effective to analyze the dynamic interaction between the static condenser and the ac transmission system.

  • PDF