• Title/Summary/Keyword: Transmission Line Parameter

Search Result 115, Processing Time 0.027 seconds

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

Study of the Applicability of the Carson Line Model for the Series Reactance Calculation of the Power Feeding Lines with no Ground Return (전송로의 직렬리앤턴스 산정 시 Carson 모델의 적용범위 검토)

  • Chung, Sang-Gi;Kwon, Sam-Young;Chang, Sang-Hoon;Jang, Dong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.225-231
    • /
    • 2009
  • In this paper, it is shown that Carson's equation can still be applied for the calculation of the series reactance of transmission lines with no ground return current as well as the one with ground return. It is proved in the following method. First two voltage drop equations for three-phase three wire transmission line are derived, one without considering ground return and the other using Carson's equation. The impedance matrix of the two equations are different from each other. But if we put the condition of zero ground current, $I_a+I_b+I_c=0$, those two equations becomes the identical equations. Therefore even a transmission line is not grounded, its line parameters can still be obtained using the Carson's equation. It has been confused whether or not Carson's equation can be used for an ungrounded system. It is because where ever Carson's equation is shown in the book, it also says that the system has ground return current paths as a premise. It is also verified with EMTP studies on the test circuit.

Study on Equivalent Circuit and Bandwidth of Short Wavelength Thin-film Transmission Line Employing ML/CPW composite structure for Miniaturization of wireless Communication System on RFIC (실리콘 RFIC 상에서 무선 통신 시스템의 소형화를 위한 마이크로스트립/코프레너 복합구조를 가지는 박막필름 전송선로의 등가회로 및 대역폭에 관한 연구)

  • Son, Ki-Jun;Jeong, Jang-Hyeon;Kim, Dong-Il;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • In this paper, we study the RF characteristics of the short wavelength thin-film transmission line employing microstrip line (ML)/coplanar waveguide (CPW) composite structure on silicon substrate for application to RFIC (radio frequency integrated circuit). The thin-film transmission line employing ML/CPW composite structure showed a wavelength shorter than conventional transmission lines. Concretely, at 10 GHz, the wavelength of the transmission line employing ML/CPW composite structure was 6.26 mm, which was 60.5 % of the conventional coplanar waveguide. We also extracted the bandwidth characteristic of the transmission line employing ML/CPW composite structure using equivalent circuit analysis. The S parameter of the equivalent circuit showed a good agreement with measured result. According to the bandwidth extraction result, the cut-off frequency of thin-film transmission line employing ML/CPW composite structure was 377 GHz. Above results indicate that the transmission line employing ML/CPW composite structure can be effectively used for application to broadband and compact RFIC.

A Study on the Defection of Arcing Faults in Transmission Lines and Development of Fault Distance Estimation Software using MATLAB (MATLAB을 이용한 송전선로의 아크사고 검출 및 고장거리 추정 소프트웨어 개발에 관한 연구)

  • Kim, Byeong-Cheon;Park, Nam-Ok;Kim, Dong-Su;Kim, Gil-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.163-168
    • /
    • 2002
  • This paper present a new verb efficient numerical algorithm for arcing faults detection and fault distance estimation in transmission line. It is based on the fundamental differential equations describing the transients on a transmission line before, during and alter the fault occurrence, and on the application of the "Least Error Squares Technique"for the unknown model parameter estimation. If the arc voltage estimated is a near zero, the fault is without arc, in other words the fault is permanent fault. If the arc voltage estimated has any high value, the faust is identified as an fault, or the transient fault. In permanent faults case, fault distance estimation is necessary. This paper uses the model of the arcing fault in transmission line using ZnO arrestor and resistance to be implemented within EMTP. One purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. In this paper, This algorithm has been designed in Graphic user interface(GUI).

A Study on the Relation Between the LSF's and Spectral Distribution of Speech Signals (Line Spectral Frequency와 음성신호의 주파수 분포에 관한 연구)

  • 이동수;김영화
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.4
    • /
    • pp.430-436
    • /
    • 1988
  • LSF(Line Spectral Frequency) derived from LPC has known as a very useful transmission parameter of speech signals, for it has a good linear interpolation characteristics and a low spectrum distortion at low bit rates coding. This paper presents that it is possible to extract directly the formant frequencies of speech signals from LSF parameter without application of FFT algorithm by comparing the distribution of LSF parameter with the frequency distribution of analysis filter. This paper suggests the advanced algorithm that results in improving the speed of convergence at analytic solution method. Also, for the flexibility of parameters, the process that transforms from LSF to LPC is presented.

  • PDF

Development of DB index method simulator for induced voltage in steady state (DB Index 방식 상시 유도전압 시뮬레이터의 개발)

  • Jun, Fu;Kwon, O.S.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.284-285
    • /
    • 2006
  • This paper presents DB Index method simulator for induced voltage to a communication line from an overhead power transmission line in steady state. DB index method is based on EMTP simulation results. The simulation is implemented for 3,500,000 cases which are combined by employing transmission line parameter of KEPCO.

  • PDF

Estimation for the Transfer Function of Transmission Line using the Temination and Input Impedances at Activated/Deactivated states (활성/비활성 상태에서의 종단과 입력 임피던스 변화를 이용한 전송선로의 전달함수 추정)

  • 이종헌;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.1
    • /
    • pp.90-97
    • /
    • 1992
  • An estimation method for the amplitude and phase response of transmission line is discussed. and applied to narrow band ISDN subscriber line. The ABCD parameters of line are evaluated from four impedance values: the standard termination impedence at activated and deactivated stares, and the input impedances of line which can be estimated at each state. Estimating input impedence, the “chirp” signal is used as incident signal and noise effect can be reduced by ensemble averaging. These ABCD parameter estimations might be applicable to ether uniform or nonuniform line. Cleary the magnitude and phase response can be obtained from estimated ABCD parameters. The numerical simulation results for N ISDN subscriber line model are included, and the estimation error introduced by deviation in load impedence is also anlyzed.

  • PDF

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

Parameter extraction and signal transient of IC interconnects on silicon substrate (실리콘기판 효과를 고려한 전송선 파라미터 추출 및 신호 천이)

  • 유한종;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.871-874
    • /
    • 1998
  • A new transmission line parameter extraction method of iC interconnects on silicon substrate is presented. To extract the acurate parameters, the silicon substrate effects were taken into account. Since the electromagnetic fields under the silicon substrate are propagated with slow wave mode, effective dielectric constant and different ground plane with the multi-layer dielectric structures were employed for inductance and capacitance matrix determination. Then accurate signal transients simulation were performed with HSPICE by using the parameters. It was shown that the simulation resutls has an excellent agreement with TDR/TDT measurements.

  • PDF