• Title/Summary/Keyword: Transient recovery voltage

Search Result 64, Processing Time 0.033 seconds

The prospective TRV analysis of 345KV transmission system (345 KV 송전계통의 고유 TRV 해석)

  • Yoon, Jae-Young;Jung, Wee-Sik;Park, Dong-Wook;Min, Suk-Won;Jung, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.397-400
    • /
    • 1989
  • The interrupting capability of circuit breaker to have an effect on stability and reliability of the power system is largely determined by the fault current and prospective TRV (prospective transient recovery voltage). The prospective TRV, which is essentially a system function determined by the elements of the connected circuit, is not constant for a given system location but is affected by a number of variables. Therefore, the purpose of this study is to analyze the prospective TRV of KEPCO's 345KV transmission system by using EMTP (Electro-Magnetic Transients Program) and to compare the calculated values with the standard values in KSB 150 (1976)

  • PDF

A Study on DC Circuit Breaker using SCR Chung Hoo Park (SCR 에 의한 직류회로차단기의 과부하차단특성개선)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF

A Study for Analysis of Transient Recovery Voltage and Control method of Circuit Breaker According to the Load condition (부하에 따른 차단기 극간의 과도회복전압 분석 및 제어기법)

  • Park, Sung-Tae;Kim, Hyoun-Su;Rhee, Sang-Bong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.253-254
    • /
    • 2008
  • 본 논문에서는 계통 부하에 따른 차단기의 최적 개폐시점 선정을 위해 지상 및 진상 부하별 과도회복전압 발생 추이를 분석하였다. 또한 모선 전압의 위상 변화에 따라 차단기의 개극 시점 변화를 통해 발생되는 과도 회복전압의 파형을 분석하여 최적의 개폐 시점 추정을 EMTP(Electro-Magnetic Transients Program) 시뮬레이션 결과로 얻고 부하에 따른 차단기 개폐 제어 방법에 대해 분석하였다.

  • PDF

Predictive Instantaneous Control of inverter for UPS (UPS용 예측 순시제어형 인버터)

  • Kim, B.J.;Kim, J.H.;Cho, J.H.;Kim, J.S.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.237-239
    • /
    • 1995
  • The inverter for UPS system is required to satisfy pure sinusoidal output voltage with very low THD(Total Harmonic distortion). This paper proposes a TMS320c31 digital signal processor based predictive instantaneous control scheme of inverter. The proposed scheme is able to satisfy the conditions; high capability, high efficiency, low audible noise and robustness of inverter. The transient state characteristics of proposed inverter has been improved. in case of power failure or recovery, nonlinear load, sudden load change or parameters variations. Finally, the performance of the proposed inverter is shown and discussed by simulation and experiment.

  • PDF

Comparison of Arc Control Ability as a Function of Configuration of Spiral Type VI Contacts by Measuring Arcing Time (아크지속시간 측정을 통한 나선형 VI 전극의 전극배치에 따른 아크제어 성능비교)

  • Kim, byoung-Chul;Park, Hong-Tae;Oh, Ill-Sung;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.184-190
    • /
    • 2009
  • One of the purposes of arc control is to change its state to the diffuse state before current zero as soon as possible. This can provide optimal conditions for full extinction of arc by minimizing the quantity of residual plasma between contacts near current zero. TRV(transient recovery voltage) occurs at current zero at the same time with current interruption. If there is substantial residual plasma near current zero it can cause 'post arc current' by the interaction of its conductance with TRV. In this paper, arc control ability as a function of configuration of spiral type VI contacts was compared on the criteria of the time taken for arc to reach to the diffuse state.

Arc-Extinguishing Characteristics of A Rotary-Arc Gas Circuit Breaker (자력소호 가스차단부의 소호특성)

  • Shin, Young-June;Park, Kyong-Yop;Song, Ki-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1593-1598
    • /
    • 1994
  • Recently rotary-arc, thermal expansion and their composite interrupters are widely used in the distribution power system because they have lots of advantages in making the larger interrupting capacity, the smaller size, the lighter weight and the less surge. A model interrupter of rotary-arc type, which has constant stroke and thermal expansion volume, was studied by varying the design parameters, i.e. the number of turns of the driving coil, the inner diameter of the moving contact, the gas pressure and the shape of the fixed contact for this project. Short cicuit current interrupting tests were conducted to the model interrupters by varying the requirements from 42% to 175% of the test voltage, interrupting current and transient recovery voltage for the test duty No.4 of 7.2kV 12.5kA single phase test. The pressure rise, minimum and maximum arcing times were analyzed for each model interrupter. All types of model interrupters showed good interrupting performances and sufficient design margins for the ratings.

  • PDF

Effects of Bay K, cAMP and Isoprenaline on the Na-Ca Exchange Current of Single Rabbit Atrial Cells (토끼 심방근에서 Na-Ca 교환 전류에 대한 Bay K, cAMP, Isoprenaline 효과)

  • Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.377-388
    • /
    • 1990
  • Ca movements during the late plateau phase in rabbit atrium implicate Na-Ca exchange. In single atrial cells isolated from the rabbit the properties of the inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The inward currents were recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of -70 mV. Followings are the results obtained: 1) When stimulated every 30 sec, the inward currents were activated and reached peak values $6{\sim}12\;ms$ after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2) The current decayed spontaneously from the peak activation and the timecourse of the relaxation showed two different phases: fast and slow phase. 3) The recovery of the inward current was tested by paired pulse of various interval. The peak current recovered exponentialy with a time course similar to that of Ca current recovery. 4) Relaxation timecourse was also affected by pulse interval and time constant was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5) The peak inward current was increased by long prepulse stimulation, Bay K, isoprenaline or c-AMP. 6) The relaxation time constant of the inward current was prolonged by Bay K or c-AMP, and shortened by isoprenaline. From the above results, it could be concluded that increase of the calcium current potentiates and prolongs intracellular calcium transients, while shortening of the timecourse by isoprenaline or short interval stimulations might be due to the facilitation of Ca uptake by SR.

  • PDF

Study of transient recovery voltage according to condition of load circuit and extraction of life estimate (부하개폐 시험시 부하조건에 따른 과도회복전압 연구와 수명예측)

  • Oh, Joon-Sick;Kim, Myoung-Seok;Han, Gyu-Hwan;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.452-453
    • /
    • 2006
  • 저압 개폐기는 에어컨, 냉동기, 쇼케이스, 산업용 청소기, 전기 온수기, 건조기, 공조기, 펌프, 콤프레셔 등의 모터제어 및 히터와 조명기기의 개폐 등에 광범위하게 이용되는 개폐장치이다. 저압 전자개폐기는 수 천회에서 수백만회까지 빈번한 개폐사용조건으로 인해 시험규격에서는 개폐시험을 통해 수명을 검증하도록 되어 있다. 이 개폐시험 회로는 규정된 전압, 전류, 역률 조건을 맞추기 위해 저항과 리액터를 직렬 연결하여 구성한다. 또한 모터와 같은 리액터 부하를 개폐하는 개폐기의 경우는 전류차단 순간 과도회복전압의 피크비와 주파수를 규정하여 적용하고 있다. IEC60947-1에서는 과도회복전압의 피크비와 주파수에 대한 규정값을 제시하고 있으며 제시된 값을 제어하기 위한 회로를 제시하고 있다. 과도회복전압의 피크비와 주파수는 개폐기 접점의 절연성능과 밀접한 관계가 있으며 수명에 치명적인 영향을 미친다. 본 연구에서는 LS산전(주) 부하개폐시험 회로의 과도회복전압 조건과 영향을 설명하고 제어하기 위한 저항과 커패시터를 적용하는 방법을 제안하고자 한다.

  • PDF

The study on the characteristics of transient recovery voltage of electromagnetic contactor (전자기 접촉기의 과도회복전압 특성에 대한 연구)

  • Kim, Geun-Yong;Ryu, Jae-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.834-835
    • /
    • 2008
  • 전자기 접촉기(electromagnetic contactor)는 교류 또는 직류 저압의 전로(電路)에 사용되는 부하개폐기의 한 종류로 전자석 코일(electromagnet coil)의 여자(勵磁)에 의하여 주 접촉자를 개폐시키는 기기이다. 일반적으로 전자기 접촉기는 단락전류를 차단하도록 설계되어 있지는 않다. 그러므로 설치 시 적절한 단락 보호가 이루어져야 하며, 반드시 접촉기의 일부분일 필요는 없다. 차단기와 퓨즈 등을 단락보호장치(SCPD, Short-Circuit Protective Device)로 많이 사용한다. 전자기 접촉기는 특히 고빈도 개폐를 목적으로 사용되는 개폐기로, 농형모터(squirrel-cage motors)의 시동, 운전 중의 정지, 플러깅(plugging, 모터가 운전하고 있는 중에 모터의 1차측 접속을 역으로 바꿔서 모터를 급격히 정지시키거나 역 회전시키는 것) 및 인칭(inching, 모터를 짧은 기간 동안 1회 또는 반복 여자해서 피동기구를 조금 이동시키는 것)에 많이 쓰인다. 이러한 기기의 개폐특성을 평가하기 위한 부하는 과도회복 전압의 진동 주파수(oscillatory frequency)와 진폭율 ${\gamma}$를 얻을 수 있도록 조정되어야 한다. 본 논문에서는 고빈도 개폐능력을 갖고 있는 전자기 접촉기의 과도회복 전압 특성과 그 특성을 얻기 위한 부하 회로의 조정방법에 대해 고찰하였다.

  • PDF

The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit (토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구)

  • Youm, Wook;Ho, Won-Kyung;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF