• Title/Summary/Keyword: Transient Phenomenon

Search Result 250, Processing Time 0.028 seconds

The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature (Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향)

  • Park, Jun-seok;Kim, Hyungdae;Bae, Sung-won;Kim, Kyung Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.567-578
    • /
    • 2015
  • Single droplet-wall collision heat transfer characteristics on a heated plate above Leidenfrost temperature were experimentally investigated considering the effects of impact velocity. The collision characteristics of the droplet impinged on the heated wall and the changes in temperature distribution were simultaneously measured using synchronized high-speed video and infrared cameras. The surface heat flux distribution was obtained by solving the three-dimensional transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition for the collision surface. As the normal impact velocity increased, heat transfer effectiveness increased because of an increase in the maximum spreading diameter and a decrease in the vapor film thickness between the droplet and heated wall. For We < 30, droplets stably rebounded from a heated wall without breakup. However, the droplets broke up into small droplets for We > 30. The tendency of the heat transfer to increase with increasing impact velocity was degraded by the transition from the rebounding region to the breakup region; this was resulted from the reduction in the effective heat transfer area enlargement due to the breakup phenomenon.

Out-of-Pile Test for Yielding Behavior of PWR Fuel Cladding Material (노외 실험을 통한 가압경수형 핵연료 피복재의 항복거동연구)

  • Yi, Jae-Kyung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.22-33
    • /
    • 1987
  • The confirmed integrity of nuclear fuel cladding materials is an important object during steady state and transient operations at nuclear power plant. In this context, the clad material yielding behavior is especially important because of pellet-clad gap expansion. During the steep power excursion, the in-pile irradiation behavior differences between uranium-dioxide fuel pellet and zircaloy clad induce the contact pressure between them. If this pressure reaches the zircaloy clad yield pressure, the zircaloy clad will be plastically deformed. After the reactor power resumed to normal state, this plastic permanent expansion of clad tube give rise to the pellet-clad gap expansion. In this paper, the simple mandrel expansion test method which utilizes thermal expansion difference between copper mandrel and zircaloy tube was adopted to simulate this phenomenon. That is, copper mandrel which has approximately three times of thermal expansion coefficient of zircaloy-4 (PWR fuel cladding material) were used in this experiment at the temperature range from 400C to 700C. The measured plastic expansion of zircaloy outer radius and derived mathematical relations give the yield pressure, yield stress of zircaloy-4 clad at the various clad wall temperatures, the activation energy of zircaloy tube yielding, and pellet-clad gap expansion. The obtained results are in good agreement with previous experimental results. The mathematical analysis and simple test method prove to be a reliable and simple technique to assess the yielding behavior and gap expansion measurement between zircaloy-4 tube and uranium-dioxide fuel pellet under biaxial stress conditions.

  • PDF

Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant (수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발)

  • Nam, Myeong Jun;Lee, Jae-Young;Jung, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.760-767
    • /
    • 2020
  • Sustainable growth of hydroelectric power plants is expected in consideration of climate change and energy security. However, hydroelectric power plants always have a risk of water hammer damage, and safety assurance is very important. The water hammer phenomenon commonly occurs during operations such as rapid opening and closing of the valves and pump/turbine shutdown in pipe systems, which is more common in cases of emergency shutdown. In this study, a computational numerical model was developed using the MOC-FDM scheme to reflect the mechanism of water hammer occurrence. The proposed model was implemented in boundary conditions such as reservoir, pipeline, valve, and pump/turbine conditions and then applied to simulate hypothetical case studies. The analysis results of the model were verified using the analysis results at the main points of the pipe systems. The model produced reasonably good performance and was validated by comparison with the results of the SIMSEN package model. The model could be used as an efficient tool for the safety assessment of hydroelectric power plants based on accurate prediction of transient behavior in the operation of hydropower facilities.

Clinical and Laboratory Characteristics of Galactokinase Hyperactivity (GALK Hyperactivity로 인한 갈락토스혈증의 임상적 특성에 관한 연구)

  • Yang, Seung Do;Lee, Jungho;Shin, Young Lim;Lee, Dong Hwan;Hong, Yong Hee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.16 no.3
    • /
    • pp.135-140
    • /
    • 2016
  • Purpose: Galactose is metabolized to galactose-1-phosphate by galactokinase (GALK), galactose-1-phosphate uridyltransferase (GALT) and UDP-galactose-4-epimerase (GALE), and galactosemia occurs when each enzyme is deficient. In Korea, unlike foreign countries, classic galactosemia is rare and transient galactosemia due to GALK hyperactivity is reported, but studies on frequency, clinical significance, and genetic variation are lacking. In this study, we analyzed the clinical characteristics of patients with galactosemia due to GALK hyperactivity. Methods: We investigated 85 patients who had an elevated galactose level in the neonatal screening test without deficiency of enzymes at Department of Pediatrics, Seoul & Bucheon Soonchunhyang University Hospital from January 2008 to June 2016. We investigated the level of galactose, galactose-1-phosphate, GALK and duration of galactose normalization, and analyzed the correlation between GALK elevation and galactose, galactose-1-phosphate and duration of galactose normalization. And the levels of galactose, galactose-1-phosphate, and duration of galactose normalization were compared between the galactose-free formula feeding group and non-feeding group. Results: Mean age of visit was $26.7{\pm}16.1days$. Duration of galactose normalization was $35.3{\pm}20.5days$. Mean galactose level was $18.5{\pm}7.3mg/dL$ in the neonatal screening and follow-up galactose level in serum was $2.3{\pm}5.4mg/dL$. The mean value of galactose-1-phosphate was $6.0{\pm}4.7mg/dL$ and the mean GALK level was $3.84{\pm}1.28{\mu}mol/Hr/gHb$. There was no significant correlation between GALK levels and galactose levels in the neonatal screening test (P=0.351), and we analyzed the correlation between GALK levels and follow-up galactose levels in serum, there was no significant correlation (P=0.101). There was a significant correlation between GALK levels and galactose-1-phosphate (P=0.015), and the correlation between GALK levels and duration of galactose normalization was not statistically significant (P=0.176). 49% of the patients were fed galactose-free formula, and 45% were not. Galactose and galactose-1-phosphate levels in the neonatal screening test were statistically significantly higher (P=0.004, 0.034) in using galactose-free formula group. Duration of galactose normalization was not related to the use of galactose-free formula (P=0.266, 0.249). Conclusion: Galactosemia due to GALK hyperactivity seems to be a temporary phenomenon and may not require galactose restriction. More research is needed on the role of the nuclear protein, racial traits and genetic variations in Korean patients.

  • PDF

An Investigation of Higher Order Forces on a Vertical Truncated Cylinder

  • Boo, Sung-Youn
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.214-214
    • /
    • 2003
  • During a model test of Hutton TLP, a "ringing" response was first observed about 20 years ago. This phenomenon is a resonant build up over the time of wave period and this burst-like motion can cause the extreme load on the TLP tether. It is often detected in the large and steep irregular waves but the generation mechanism leading to the "ringing" is not yet well understood. According to the research since then, the higher order harmonic components may account for the "ringing" on the floating offshore structures. The main purpose of the present research is, thus, to measure the higher harmonic forces exerted on a vertical truncated circular column and to compare them with available data. A vertical truncated cylinder with a diameter of 3.5inch and a draft of 10.5inch is used as a test structure, which is a scaled model of ISSC TLP column. The cylinder is installed at a distance of 45ft from the wave maker in order to avoid parasitic waves created in the wave flap. Attached to the upper part of the cylinder are two force gages to measure the horizontal (surge) and vertical (heave) forces on the cylinder. The incoming waves are Stokes waves with a slope ranging from 0.06 to 0.24. The forces and waves are measured for 60 seconds with a sampling rate of 50 Hz. Among the recorded data, the first 10 waves are excluded because of transient behavior of the waves and the next The horizontal and vertical forces are analyzed up to 5th order harmonics. The horizontal forces are then compared to the values from the theoretical model called "FNV model". In addition, force transfer functions are also investigated. Major findings in this research are below. 1) The first order forces measured are slightly larger than the theoretical values of "FNV model" 2) The "FNV model" considerably overpredicts the second order forces. 3) The larger the amplitude and more extreme the wave slope, the smaller the predictions are compared to the experimental. 4) The higher harmonic forces are significantly smaller than the first harmonic force for all wave parameters. 5) The normalized forces vs. waves slopes are almost constant in the lower harmonics but vary a lot in the higher harmonics. 6) The trend of forces is more nonlinear in the horizontal forces than in the vertical forces as the wave slope increases. 7) The part of the results above is also observed by other researchers and confirmed again through the present work.

  • PDF

Investigation of dust particle removal efficiency of self-priming venturi scrubber using computational fluid dynamics

  • Ahmed, Sarim;Mohsin, Hassan;Qureshi, Kamran;Shah, Ajmal;Siddique, Waseem;Waheed, Khalid;Irfan, Naseem;Ahmad, Masroor;Farooq, Amjad
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.665-672
    • /
    • 2018
  • A venturi scrubber is an important element of Filtered Containment Venting System (FCVS) for the removal of aerosols in contaminated air. The present work involves computational fluid dynamics (CFD) study of dust particle removal efficiency of a venturi scrubber operating in self-priming mode using ANSYS CFX. Titanium oxide ($TiO_2$) particles having sizes of 1 micron have been taken as dust particles. CFD methodology to simulate the venturi scrubber has been first developed. The cascade atomization and breakup (CAB) model has been used to predict deformation of water droplets, whereas the Eulerian-Lagrangian approach has been used to handle multiphase flow involving air, dust, and water. The developed methodology has been applied to simulate venturi scrubber geometry taken from the literature. Dust particle removal efficiency has been calculated for forced feed operation of venturi scrubber and found to be in good agreement with the results available in the literature. In the second part, venturi scrubber along with a tank has been modeled in CFX, and transient simulations have been performed to study self-priming phenomenon. Self-priming has been observed by plotting the velocity vector fields of water. Suction of water in the venturi scrubber occurred due to the difference between static pressure in the venturi scrubber and the hydrostatic pressure of water inside the tank. Dust particle removal efficiency has been calculated for inlet air velocities of 1 m/s and 3 m/s. It has been observed that removal efficiency is higher in case of higher inlet air velocity.

Prefectural Archives and Records Management at Prefectural Governments in Japan (일본(日本)의 지방공문서관(地方公文書館)과 지방기록관리(地方記錄管理) -문서관(文書館)과 역사자료관(歷史資料館)의 설립과정을 중심으로-)

  • Kim, Jong-Chul
    • The Korean Journal of Archival Studies
    • /
    • no.11
    • /
    • pp.215-254
    • /
    • 2005
  • This thesis aims to study the founding process and operation of the prefectural archives of Japan and to put that knowledge to the founding regional archives in Korea. Now 28 among 47 Prefectural Governments in Japan have founded and operated the prefectural archives. While Kyoto Prefectural Library and Archives, Nagano Prefectural Museum of History, Gifu Prefectural Virtual Museum of History, The Archives of Hyogo Prefectural Government, Ibaraki Prefectural Museum of History and Hukushima Prefectural Archives are on the type of Prefectural Museum of History, the rest of them are on the type of Archives. The Prefectural Museum of History in Japan has a complex function as the museum, the library, and the archives. But the Prefectural Museum of History seems to be a sort of transient phenomenon to Archives. The reason which Prefectural Museum of History can not develop into the Archives is not so much owing to financial difficulties as lack of understanding on the function of Archives. The thesis shows founding process of each prefectural archives. Especially, the case study on the Kanagawa Prefectural Archives, Okinawa Prefectural Archives was arranged by the detailed data investigation. Comparing with other prefectures, these three prefectural archives have a system in the collection and arrangement process of current official records, paleography and many other materials, and construct records management system with institutionalizing accession, arrangement, and opening of official records by regulations, rules and so forth. But because of historical background and character in each region, the difference may exist in the founding process of three prefectural archives. Before central archival institution, National Archives of Japan, is founded, the prefectural archives have been founded at each region and they have gained relatively independent status so that decentralism in the system of managing records could be possible. And the private historical organizations had many influences on the founding process of National Archives of Japan. Of course the Japanese Archives system may have many differences from Korean regional archives. While Japan established Archives institute for itself with localism, Korea has not settled the system of self-government still. Moreover, financial difficulties on founding regional archives and lack of understanding of the Archives remained in Korea. And yet with regard to the founding regional archives in Korea, the case of operation and founding process of prefectural archives of Japan may be of great value.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

A Study on Solving ESG Issues focusing on Pet Problems (메타버스에서의 반려동물을 중심으로 한 ESG 문제 해결 설계)

  • Eunjin Kim;Woori Kim;Seunghoon Choi;Nayoon Song;Hyunseo Jang;Jinsil Ahn;Mingu Lee;Juhvun Eune
    • Smart Media Journal
    • /
    • v.13 no.5
    • /
    • pp.52-61
    • /
    • 2024
  • The onset of the COVID-19 pandemic has accelerated social transformations across various nations. These changes, particularly prominent in the corporate and industrial sectors, have necessitated a shift towards increased remote activities, fundamentally altering societal structures. Within this context, the concept of the Metaverse, a virtual world existing since the early 2000s but previously underrecognized, began to gain widespread recognition. In South Korea, major tech companies such as Naver, Kakao, and Coupang have long normalized remote working, with new employee orientations also taking place on Metaverse platforms. Beyond the IT sector, institutions requiring large gatherings, such as schools, have adopted the Metaverse for hosting major events like welcome ceremonies and informational sessions. This phenomenon suggests that the Metaverse is not merely a transient social trend but is gradually integrating into the daily lives of the general populace, serving as a significant social connector. This study explores the potential of Metaverse-enabled design thinking and methodologies to address the Environmental, Social, and Governance (ESG) challenges faced by Korean society. Specifically, the research focuses on developing solutions for social issues related to pets in Korea.

Adult Attachment Styles and Insomnia (성인 애착유형과 불면증)

  • Kim, Dong-Wook;Lee, Kyung-Hwa;Cho, Seong-Jin;Cho, In-Hee;Koh, Seung-Hee;Lee, Yu-Jin;Kim, Jong-Hoon;Kim, Seog-Ju
    • Sleep Medicine and Psychophysiology
    • /
    • v.16 no.1
    • /
    • pp.28-35
    • /
    • 2009
  • Introduction: Human attachment is known to be closely associated with psychophysiological phenomenon. However, there have not been enough researches on the relationship of the attachment with sleep, especially with insomnia. The objective of the present study was to investigate the relationship between adult attachment styles and insomnia in community-dwelling population. Methods: One hundred seventy seven community-dwelling adults (74 males and 103 females;mean age $41.23{\pm}8.44$) participated in the current study. To assess the attachment styles (secure, dismissing, preoccupied and fearful), self-reporting Relationship Style Questionnaires (RSQ) were completed by the participants. Presence, type, frequency and duration of insomnia in the last month were also investigated. Results: Compared to subjects without insomnia, subjects with insomnia had higher fearful attachment scores (t=2.87, p=0.005). Higher fearful attachment score were found in all subtypes of insomnia (sleep-onset insomnia, t=2.33, p=0.021;maintenance insomnia, t=2.92, p=0.004;terminal insomnia, t=2.89, p=0.004). Subjects with frequent (${\ge}3$ per week) insomnia had higher fearful attachment scores than subjects with infrequent (${\le}2$ per week) insomnia (t=2.57, p=0.012). In addition, subjects with chronic insomnia (${\ge}6$ months) had higher preoccupied attachment scores relative to subjects with transient insomnia (<6 months), (t=2.57, p=0.012). Conclusion: In the current study, attachment styles were different depending on the characteristics of insomnia. The fearful attachment was associated with the presence of insomnia, while the preoccupied attachment was associated with the chronicity of insomnia. These findings suggest that there may be some relationship between the adult attachment styles and the clinical features of insomnia.

  • PDF