• Title/Summary/Keyword: Transient Operation

Search Result 804, Processing Time 0.028 seconds

Minimum 2-Year Follow-Up Result of Degenerative Spinal Stenosis Treated with Interspinous U ($Coflex^{TM}$)

  • Park, Seong-Cheol;Yoon, Sang-Hoon;Hong, Yong-Pyo;Kim, Ki-Jeong;Chung, Sang-Ki;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.292-299
    • /
    • 2009
  • Objective : Clinical and radiological results of posterior dynamic stabilization using interspinous U (ISU, $Coflex^{TM}$, Paradigm Spine $Inc.^{(R)}$, NY, USA) were analyzed in comparison with posterior lumbar interbody fusion (PLIF) in degenerative lumbar spinal stenosis (LSS). Methods : A retrospective study was conducted for a consecutive series of 61 patients with degenerative LSS between May 2003 and December 2005. We included only the patients completed minimum 24 months follow up evaluation. Among them, 30 patients were treated with implantation of ISU after decompressive laminectomy (Group ISU) and 31 patients were treated with wide decompressive laminectomy and posterior lumbar interbody fusion (PLIF; Group PLIF). We evaluated visual analogue scale (VAS) and Oswestry Disability Index (ODI) for clinical outcomes (VAS, ODI), disc height ratio disc height (DH), disc height/vertebral body length ${\times}100$), static vertebral slip (VS) and depth of maximal radiolucent gap between ISU and spinous process) in preoperative, immediate postoperative and last follow up. Results : The mean age of group ISU ($66.2{\pm}6.7$ years) was 6.2 years older than the mean age of group PLIF ($60.4{\pm}8.1$ years; p=0.003). In both groups, clinical measures improved significantly than preoperative values (p<0.001). Operation time and blood loss was significantly shorter and lower in group ISU than group PLIF (p<0.001). In group ISU, the DH increased transiently in immediate postoperative period ($15.7{\pm}4.5%{\rightarrow}18.6{\pm}5.9%$), however decreased significantly in last follow up ($13.8{\pm}6.6%$, p=0.027). Vertebral slip (VS) of spondylolisthesis in group ISU increased during postoperative follow-up ($2.3{\pm}3.3{\rightarrow}8.7{\pm}6.2$, p=0.040). Meanwhile, the postoperatively improved DH and VS was maintained in group PLIF in last follow up. Conclusion : According to our result, implantation of ISU after decompressive laminectomy in degenerative LSS is less invasive and provides similar clinical outcome in comparison with the instrumented fusion. However, the device has only transient effect on the postoperative restoration of disc height and reduction of slip in spondylolisthesis. Therefore, in the biomechanical standpoint, it is hard to expect that use of Interspinous U in decompressive laminectomy for degenerative LSS had long term beneficial effect.

The Change of Cardiothoracic Ratio after Ligation of Patent Ductus Arteriosus in Adult -Report of 30 cases- (성인의 동맥관 개존증 결찰술 시행후 심흉비의 변화 -30례 보고-)

  • 황상원;이연재;김한용;유병하
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.22-26
    • /
    • 1999
  • Background: Treatment of adult patent ductus arteriosus(PDA) has many difficulty such as pulmonary hypertension, arterial wall calcification, aneurysmal chage of ductus. We tried to evaluate the effect of surgical interruption of PDA on postopeative change of heart size. Material and Method : From 1987 to 1997 we experienced 30 cases of the ligation of patent ductus arteriosus in adult at the department of cardiovacular surgery in Masan Samsung General Hospital. Result: There were 9 males and 21 females and their ages ranged from 16 to 44 years, with a mean age of 26.1 years. 15 patients had pulmonary hypertension and 9 patients complained of dyspnea with a degree of functional NYHA class III. Operation method was double or triple ligation using Teflon felt. Postoperative complications were wound dehiscence in 3 patients and transient hoarseness in 1 patient. The mean preoperative cardiothoracic ratio was 54.7%, and mean postoperative cardiothoracic ratio was 51.9%. The change of cardiothoracic ratio was more typical in the cases who had congestive heart failure. Their mean preoperative cardiothoracic ratio was 64.8% and the mean postoperative cardiothoracic ratio was 58.5% there was no postoperative deaths. Conclusion: We canclude that the improvement in cardiothoracic ratio may result from surgical intervention of PDA.

  • PDF

Analysis of Total Loss of Feedwater Event for the Determination of Safety Depressurization Bleed Capacity (안전감압계통의 방출유량을 결정하기 위한 완전급수상실사고 해석)

  • Kwon, Young-Min;Song, Jin-Ho;Ro, Tae-Sun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.470-482
    • /
    • 1995
  • The Ulchin 3&4, which are 2825 MWt PWRs, adopted Safety Depressurization System (SDS) to mitigate the beyond design basis event of Total Less of Feedwater(TLOFW). In this study the results and methodology of the analyses for the determination of SDS bleed capacity are discussed. The SDS design bleed capacity has been determined from the CEFLASH-4AS/REM simulation according to the following design criteria : 1) Each SDS flow path, in conjunction with one of two High Pressure Safety Injection (HPSI) pumps, is designed to have a sufficient capacity to prevent core uncovery if one SDS path is opened simultaneously with the opening of the Pressurizer Safety Valves (PSVs). 2) Both SDS bleed paths are designed to have sufficient total capacity with both HPSI pumps operating to prevent core uncovery if the Feed and Bleed (F&B) initiation is delayed up to thirty minutes from the time of the PSVs lift. To verify the results of CEFLASH-4AS/REM simulation a comparative analysis kas also been per-formed by more sophisticated computer code, RELAP5/MOD3. The TLOFW event without operator recovery and TLOFW event with F&B are analyzed. The predictions by the CEFLASH-4AS/REM of the transient too phase system behavior are in good qualitative and quantitative agreement with those by the RELAP5/MOD3 simulation. Both of the results of analyses by CEFLASH-4AS/REM and RELAP5/MOD3 have demonstrated that decay heat removal and core inventory make-up can be successfully accomplished by F&B operation during now event for the Ulchin 3&4.

  • PDF

Investigation of dust particle removal efficiency of self-priming venturi scrubber using computational fluid dynamics

  • Ahmed, Sarim;Mohsin, Hassan;Qureshi, Kamran;Shah, Ajmal;Siddique, Waseem;Waheed, Khalid;Irfan, Naseem;Ahmad, Masroor;Farooq, Amjad
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.665-672
    • /
    • 2018
  • A venturi scrubber is an important element of Filtered Containment Venting System (FCVS) for the removal of aerosols in contaminated air. The present work involves computational fluid dynamics (CFD) study of dust particle removal efficiency of a venturi scrubber operating in self-priming mode using ANSYS CFX. Titanium oxide ($TiO_2$) particles having sizes of 1 micron have been taken as dust particles. CFD methodology to simulate the venturi scrubber has been first developed. The cascade atomization and breakup (CAB) model has been used to predict deformation of water droplets, whereas the Eulerian-Lagrangian approach has been used to handle multiphase flow involving air, dust, and water. The developed methodology has been applied to simulate venturi scrubber geometry taken from the literature. Dust particle removal efficiency has been calculated for forced feed operation of venturi scrubber and found to be in good agreement with the results available in the literature. In the second part, venturi scrubber along with a tank has been modeled in CFX, and transient simulations have been performed to study self-priming phenomenon. Self-priming has been observed by plotting the velocity vector fields of water. Suction of water in the venturi scrubber occurred due to the difference between static pressure in the venturi scrubber and the hydrostatic pressure of water inside the tank. Dust particle removal efficiency has been calculated for inlet air velocities of 1 m/s and 3 m/s. It has been observed that removal efficiency is higher in case of higher inlet air velocity.

Thermal Energy Balance Analysis of a Packed Bed for Rock Cavern Thermal Energy Storage (충전층을 이용한 암반공동 열에너지저장시스템의 열에너지 수지 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.241-259
    • /
    • 2013
  • A packed bed thermal energy storage (TES) consisting of solid storage medium of rock or concrete through which the heat transfer fluid is circulated is considered as an attractive alternative for high temperature sensible heat storage, because of the economical viability and chemical stability of storage medium and the simplicity of operation. This study introduces the technologies of packed bed thermal energy storage, and presents a numerical model to analyze the thermal energy balance and the performance efficiency of the storage system. In this model, one dimensional transient heat transfer problem in the storage tank is solved using finite difference method, and temperature distribution in a storage tank and thermal energy loss from the tank wall can be calculated during the repeated thermal charging and discharging modes. In this study, a high temperature thermal energy storage connected with AA-CAES (advanced adiabatic compressed air energy storage) was modeled and analyzed for the temperature and the energy balance in the storage tank. Rock cavern type TES and above-ground type TES were both simulated and their results were compared in terms of the discharging efficiency and heat loss ratio.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

Simulation of Past 6000-Year Climate by Using the Earth System Model of Intermediate Complexity LOVECLIM (중간복잡도 지구시스템모델 LOVECLIM을 이용한 과거 6천년 기후 변화 모의)

  • Jun, Sang-Yoon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 2019
  • This study introduces the overall characteristics of LOVECLIM version 1.3, the earth system model of intermediate complexity (EMIC), including the installation and operation processes by conducting two kinds of past climate simulation. First climate simulation is the equilibrium experiment during the mid-Holocene (6,000 BP), when orbital parameters were different compared to those at present. The overall accuracy of simulated global atmospheric fields by LOVECLIM is relatively lower than that in Coupled Model Intercomparison Project phase 5 (CMIP5) and Paleoclimate modelling Intercomparison Project phase 3 (PMIP3) simulations. However, surface temperature over the globe, the 800 hPa meridional wind over the mid-latitude coastal region, and the 200 hPa zonal wind from LOVECLIM show similar spatial distribution to those multi-model mean of CMIP5/PMIP3 climate models. Second one is the transient climate experiment from mid-Holocene to present. LOVECLIM well captures the major differences in surface temperature between preindustrial and mid-Holocene simulations by CMIP5/PMIP3 multi-model mean, even though it was performed with short integration time (i.e., about four days in a single CPU environment). In this way, although the earth system model of intermediate complexity has a limit due to its relatively low accuracy, it can be a very useful tool in the specific research area such as paleoclimate.

Outcomes of the Warden Procedure for Anomalous Pulmonary Venous Return to the Superior Vena Cava: A 17-Year Experience

  • Lim, Su Chan;Kwak, Jae Gun;Cho, Sungkyu;Min, Jooncheol;Lee, Sangjun;Kwon, Hye Won;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.55 no.3
    • /
    • pp.206-213
    • /
    • 2022
  • Background: Surgical repair of partial anomalous pulmonary venous return (PAPVR) to the superior vena cava (SVC) using the Warden procedure has favorable outcomes. However, there remain some concerns after the Warden procedure, such as sinoatrial nodal dysfunction and systemic or pulmonary venous stenosis. We investigated the outcomes of the Warden procedure for repair of PAPVR to the SVC. Methods: This retrospective study included 22 consecutive patients who underwent the Warden procedure for PAPVR between 2002 and 2018. The median age and body weight at operation were 27.5 months (interquartile range [IQR], 5.0-56.8 months) and 13.2 kg (IQR, 6.5-16.0 kg), respectively. The median follow-up duration was 6.2 years (IQR, 3.5-11.6 years). Results: There were no cases of early or late mortality. No patients had postoperative heart rhythm problems, except 1 patient who showed transient sinoatrial nodal dysfunction in the immediate postoperative period. Procedure-related complications requiring reintervention occurred in 5 patients, including 3 of 4 SVC stenosis cases and 2 pulmonary venous stenosis cases during follow-up. The rate of freedom from reintervention related to the Warden procedure was 75.9% at 10 years. Conclusion: In cases requiring extension or creation of an atrial septal defect to achieve a sufficient venous pathway, or interposition of an entire circumferential conduit between the SVC and right atrium due to the shortness of the SVC in the Warden procedure, stenotic complications of the venous pathway occurred. Careful observation of changes in the pressure gradient or anatomical stenosis is required in such patients.

A Study on a Sliding Mode Control Algorithm for Dynamic Positioning System of a Vessel (선박의 동적위치유지 시스템을 위한 Sliding Mode 제어 연구)

  • Young-Shik Kim;Jang-Pyo Hong
    • Journal of Navigation and Port Research
    • /
    • v.47 no.4
    • /
    • pp.256-270
    • /
    • 2023
  • In this study, a sliding mode (SM) controller for dynamic positioning (DP) was specifically designed for a turret connection operation of a ship or an offshore structure in which an arbitrary point on the structure could be controlled as the motion center instead of the center of mass. The SM controller allows control of the arbitrary point and provides capability to manage uncertainties in the dynamics of ships and offshore structures, external forces caused by unknown changing marine environments, and transient performance of DP systems. The Jacobian matrix included in kinematic equations of the controlled object was modified to design the SM controller to control based on an arbitrary point of ships or offshore structures. To ensure robustness of the controller, the Lyapunov stability theory was applied in the design of the SM controller. In general, for robustness in DP control, gain scheduling based on a proportional-derivative (PD) control algorithm is employed. However, finding appropriate gains for gain scheduling complicates the application of DP systems. Therefore, in this study, the SM control algorithm was considered to mitigate the complexity of the DP controller for ships and offshore structures. To validate the proposed SM control algorithm, time-domain simulations were conducted and utilized to evaluate the performance of the control algorithm. The effectiveness of the proposed SM controller was assessed by comparing simulation results with results of a conventional PD control algorithm applied in DP control.

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.