• Title/Summary/Keyword: Transformer block

Search Result 41, Processing Time 0.031 seconds

A Numerical Simulation of Heat and Fluid Flow in the Motor Block Room of a Motorized Car (동력객차 동력실 내부의 열유체 유동의 수치 시뮬레이션)

  • 김학범;허재경;이기열
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.589-594
    • /
    • 1998
  • Heat and fluid flow in the motor block room of a motorized car is numerically simulated. The motorized car, composed of a motor block room and a passenger room, supplies additional Power to achieve the design speed. A motor block, a transformer, and a fan are equipped in the motor block room. Flow phenomena in the ducts on the motor block and power transformer are investigated. Also, the three dimensional heat and fluid flow in the motor block room is simulated to give a qualitative information of the flow characteristics.

  • PDF

Optimal Design of Wound core type Transformer by Equivalent Anesotropic Block (권철심변압기의 등가이방성모델을 이용한 최적설계)

  • Im, D.H.;Kwon, B.I.;Park, S.C.;Lee, J.H.;Kim, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.156-158
    • /
    • 1994
  • The analysis of the thin lamination model of the amorphous transformer by FEM requires many region, divisions and much calculating tine, and it has difficulty in calculating for mordern computer. A new method which is simulated by a solid but anisotropic block with the magnetic permeabilities in two orthogonal directions selected to account for the presence of the laminations. [1] Based on this equivalent anisotropic block model, we analyzed the iron loss of the amorphous transformer by FEM, and presented an optimal design example of core dimensions for minimizing the iron loss.

  • PDF

Analysis of Iron Loss in a Wound Core Type Transformer by FEM (유한요소법에 의한 권철심변압기의 철손해석)

  • Kwon, B.I.;Kim, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.21-23
    • /
    • 1995
  • The analysis of the thin lamination model of the wound core type transformer by FEM requires many region division and much calculationg time, and it has difficulty in calculation by modem computer. A new method which is simulated by a solid but anisotropic block with the magnetic permeabilities in the orthogonal dimension, is selected to account for the presence of the lamination.[1] Based on this equivalent anisotropic block model, we analyze the iron loss of the wound core type transformer by FEM, and compare the simulation results with the experimental results.

  • PDF

Design of wide Band Microwave Amplifier with Good Frequncy Characteristics (주파수 특성이 좋은 광대역 마이크로웨이브 증폭기의 설계)

  • Kang, Hee-Chang;park, Il;Chin, Youn-kang
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 1991
  • The new structure method of GaAs microwave amplifiers using DC block function and impedance transforming property of DC block/transformer(non-symmetrical two - microstrip coupled line and interdigital three - microstrip coupled line), instead of chip capacitor, is presented. The newly structured microwave amplifier showed wideband characteristics(bandwidth, 3.5 GHz) and flat frequency response. Interdigital three - microstrip coupled line which is used for microwave amplifier can be used to match amplifiers as well as DC blocking.

  • PDF

A Study on the 2nd Harmonic Blocking Scheme and Setting Value of a Current Differential Relay for 154 kV Transformers to Prevent Maloperation (154 kV 변압기 보호용 비율차동계전기 오동작 방지를 위한 2고조파 억제 방식의 적용방법 및 정정값에 관한 연구)

  • Son, Yong-Beom;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.29-37
    • /
    • 2018
  • Inrush current and fault current in a transformer need to be distinguished from one another. In order to do this, KEPCO uses a 2nd harmonic restraint/block method. We use two setting values for 2nd harmonic restraint; 15% and 10%. We also apply per-phase blocking method among various harmonic restraint methods. If the transformer is located at the radial system, we adjust 10% in the 2nd harmonic restraint, but this method is not enough to prevent mal-operations of the current differential relay and let us spend more time to change setting value again as the power system changes. In this paper, a more reasonable setting value for a 2nd harmonic blocking scheme in KEPCO is proposed. To present a proposed method, the fault data of the current differential relays which have occurred since 2009 are analyzed. To evaluate the performance of the proposed method, the results of the RTDS test for the current differential relay of the transformer by KEPCO are analyzed.

Combined test of Power Supply System for Korean High Speed Train (고속전철용 보조전원장치 시스템 조합시험)

  • Cho, Hyun-Wook;Kim, Yuen-Chung;Kim, Tae-Hwan;Jang, Kyung-Hyun;Kim, Chul-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.619-625
    • /
    • 2008
  • Electrical Power supply System conditions of korea high speed train consists of main transformer, four AC-DC PWM converter of Auxiliary Block, Battery Charger in Power Car and Trailer Car, Trailer Inverter, Auxiliary inverter. Main transformer, at nominal voltage of 25kv supplied to secondary winding nominal output Voltage 383Vac, The Auxiliary block consists of AC-DC converters for generating 670VDC power, Auxiliary inverters for ventilation and air compressor, Trailer car inverter provide three phase power supplies at 440Vac for air conditioning and heating. The Battery charger Trailer and Power car supplies 72VDC all necessary equipment to energize the trainset equipment and suppy essential control. This Paper introduces the combined test results of the power supply system for korea high speed train. The main purpose of this combined test is to verify the performance of the power supply system that is designed to operate up to full load test.

  • PDF

A Study on the Tank Noise Reduction Techniques of Power Transformers (전력용 변압기 외함 소음저감에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chan;Kim, Yoo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1759-1766
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.

Deep Learning based Skin Lesion Segmentation Using Transformer Block and Edge Decoder (트랜스포머 블록과 윤곽선 디코더를 활용한 딥러닝 기반의 피부 병변 분할 방법)

  • Kim, Ji Hoon;Park, Kyung Ri;Kim, Hae Moon;Moon, Young Shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.4
    • /
    • pp.533-540
    • /
    • 2022
  • Specialists diagnose skin cancer using a dermatoscopy to detect skin cancer as early as possible, but it is difficult to determine accurate skin lesions because skin lesions have various shapes. Recently, the skin lesion segmentation method using deep learning, which has shown high performance, has a problem in segmenting skin lesions because the boundary between healthy skin and skin lesions is not clear. To solve these issues, the proposed method constructs a transformer block to effectively segment the skin lesion, and constructs an edge decoder for each layer of the network to segment the skin lesion in detail. Experiment results have shown that the proposed method achieves a performance improvement of 0.041 ~ 0.071 for Dic Coefficient and 0.062 ~ 0.112 for Jaccard Index, compared with the previous method.

A Study on the Core Noise Reduction Techniques of Power Transformers (전력용 변압기 철심소음 저감기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Cho, Ik-Choon;Kim, Yoo-Hyun;Kim, Yung-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1962-1969
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.

Fuzzy Logic Based Relaying Using Flux-differential Current Derivative Cure for Power Transformer Protection

  • Kwon, Myoung-Hyun;Park, Chul-Won;Suh, Hee-Seok;Lee, Bock-Gu;Shin, Myong-Chul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.5
    • /
    • pp.72-82
    • /
    • 1998
  • Power transformer protective relay should block the tripping during magnetizing imrush and rapidly operate the tripping during internal faults. But traditional approaches maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmounic component. To enhance the fault detection sensitivities of conventional technuques, flux-differential current derivative curve by fuzzy theory approaches is used. This paper deals with fuzzy logic based protective relaying for power transformer. The proposed fuzzy based relaying algorithm consisits of flux-differential current derivative curve, harmonics restraint, and precentage differential characteristic curv. The proposed relaying was tested with relaying signals obtained from Salford EMTP simulation package and showed a fast and accurate trip operation.

  • PDF