• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 0.027 seconds

A Study on the Aging Diagnosis of Transformer oil by Spectrometric and Electroanalytical Methods (분광광도법 및 전기분석법을 이용한 절연유의 경년열화 진단에 관한 연구)

  • 김경렬;곽희로;윤영자;남궁미옥;이동준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.15-20
    • /
    • 1998
  • The furfural, generated by decomposition of insulating paper, the amount of metal in insulating oil, and tano(electrical properties of insulating oil)have been studied for the insulating oil in pole transformer with accelarated thermal aging test. It has been found that tan $\delta$ is affected by adding components of the transformer. The examination of amount of metal, which exhibits catalytic behavior to oxidation of insulating oil, suggested that the amounts of copper increase with degradation time. A comparison between tano and copper amount suggested that the amounts of copper for attention are above 0.2[pp]). Finally, the examination of amount of furfural revealed that the amounts of furfural increase with degradation time. As a consequence, these results could be used for diagnosis of pole transformer.former.

  • PDF

The Study on the Safety Algorithm of Switchboard Considering Overload of Transformer in Distribution System (배전용 변압기의 과부하상태를 고려한 수배전반 안전 알고리즘에 관한 연구)

  • Chu, Cheol-Min;Kim, Jae-Chul;Kang, Bong-Suk;Ryu, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.286-287
    • /
    • 2006
  • In this paper, an experiment result on overload of distribution transformer was arranged by top oil temperature depending on capacity and time. This result shows the definition on overload of transformer is different by some factors such as ambient temperature and immediate load. In other words, increased temperature in range of regulation(50K) has time to spare even if the condition of transformer is overload. The algorithm presented in this paper is based on the international standard (IEEE std C57.91), and the safety of switchboard is diagnosed by this aspect mentioned on overload of transformer.

  • PDF

A Study on Safty Diagnosis and Evaluation of Oil Transformer using Fuzzy Algorithm (퍼지알고리즘을 이용한 유증 변압기의 안전진단 및 평가에 관한 연구.)

  • Kim, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.67-68
    • /
    • 2006
  • In this paper, we introduced about safety algorithm of transformer for MV/LV distribution customers using by fuzzy theory. Overload of transformer becomes different by surrounding temperature. And parameters about overload of transformer are connection each other. Therefore, we organize safety algorithm consider overload of transformer and surrounding temperature in this research. And we induce the relational expression of each parameters using experiment data of IEEE std C57.91-1995. Deduction of result used fuzzy reasoning. We guess the safety algorithm suggested in this paper shows the new direction that heavy electrical equipments including switchboard are going to develop in the future.

  • PDF

A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration (유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

PNN based Rogers Diagnosis Method for Fault Classification of Oil-filled Power Transformer (유입변압기 고장분류를 위한 PNN 기반 Rogers 진단기법 개발)

  • Lim, Jae-Yoon;Lee, Dae-Jong;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.280-284
    • /
    • 2016
  • Stability and reliability of a power system in many respects depend on the condition of power transformers. Essential devices as power transformers are in a transmission and distribution system. Being one of the most expensive and important elements, a power transformer is a highly essential element, whose failures and damage may cause the outage of a power system. To detect the power transformer faults, dissolved gas analysis (DGA) is a widely-used method because of its high sensitivity to small amount of electrical faults. Among the various diagnosis methods, Rogers diagonsis method has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using PNN(Probability Neural Network) based Rogers diagnosis method. The test result show better performance than conventional Rogers diagnosis method.

A Numerical Model of the Electric Field Distribution in Power Transformers (전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델)

  • Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

Economic Evaluation of HTS Transformer by Predicting Market Penetration Price (초전도변압기 시장진입가격 예측을 통한 경제성 분석)

  • 김종율;이승렬;윤재영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.507-512
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire. In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In these days, companies world-wide have conducted researches on HTS transformer. A development project for a 154kV HTS transformer is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated. which HTS transformer is competitive against conventional transformer.

A Study of the Streaming Electrostatic Current in High Voltage - Large Power Transformer (초고압 대용량 변압기에서의 유동대전 현상에 관한 연구(전압무인가))

  • Park, Jae-Yun;Yun, Seung-Jin;Minari, Kogane;Lee, Duck-Chool;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.176-179
    • /
    • 1990
  • In this paper, the pheonmena of flowing electrification is experimently studied in the model transformer of a super high voltage transformer. The current of natural terminal which is flowed by the flowing electrification is increased according to oil flow, but according to the oil temperature the current is decreased and the direction of the current is changed.

  • PDF

Fault Diagnosis of Oil-filled Power Transformer using DGA and Intelligent Probability Model (유중가스 분석법과 지능형 확률모델을 이용한 유입변압기 고장진단)

  • Lim, Jae-Yoon;Lee, Dae-Jong;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.188-193
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using DGA and Intelligent Probability Model. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer (주상용 몰드변압기의 온도분포 해석과 온도상승 시험)

  • 조한구;이운용;김석수;이종득
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.780-782
    • /
    • 2001
  • The mold transformer has anti-burnt and possibility of small size contrary to oil-immersed transformer. The mold transformer has generally cooling duct between low voltage coil and high voltage coil and also made by one body molding for small size and low loss. In this paper, the temperature distribution of designed 50kVA pole mold transformer for power distribution is investigated by FEM program. The designed transformer is also manufactured and temperature rise test is carried out.

  • PDF