• Title/Summary/Keyword: Transformer Oil

Search Result 400, Processing Time 0.022 seconds

Analysis of the Damage Patterns and Metal Structure of 3 Phase Mold Transformers to which Interlayer Short-circuits have Occurred (층간 단락된 3상 몰드변압기의 소손 패턴 및 금속 조직 해석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • The purpose of this study is to analyze the damage patterns and metal structure of 3 phase mold transformers collected from places where accidents have occurred. Compared to an oil-immersed transformer, a mold transformer has the advantage of requiring a smaller installation area and can be kept clean, while its disadvantages include the fact that abnormal symptoms of an accident are difficult to discover and its repair is impossible. The capacity of the mold transformers collected from places where accidents have occurred was 200kVA with primary voltages being F23,900V, R22,900V, 21,900V, 20,900V, 19,900V, etc., as well as secondary voltages being 380V, 220V, etc. It was found from the analysis on the diffusion of combustion in the damaged mold transformers that fire occurred first inside the U-phase primary winding and that carbonization and heat were diffused to V-phase and W-phase in V-pattern. In addition, from the analysis on the cross-sectional structure of the metal of the melted high voltage winding using a metallurgical microscope, it was found that the boundary surface, voids, and columnar structure were formed when an interlayer short-circuit had occurred Therefore, even though it is not possible to find the cause for the occurrence of an interlayer short-circuit at the inner side of the primary winding, it is thought that, due to the thermal energy generated when the short-circuit occurred, the heat source was diffused to the upper side and outside, causing a secondary accident.

Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer (몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구)

  • Kim, Moosun;Jang, Dong Uk;Kim, Seung Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.511-517
    • /
    • 2016
  • Current oil-type potential transformers for trains are filled with insulating oil, which could have problems like explosions due to rising inner pressure during train operation. Therefore, mold and dry-type potential transformers are being developed to prevent explosions. One problem in manufacturing mold-type transformers is preventing void formation around the coiled core inside the mold during epoxy filling, which could cause an electrical spark. Micro voids can remain in the resin after filling, and macro voids can occur due to the structure shape. A transformer that is being developed has a cavity at the junction of the core and the coil for better performance, and when highly viscous epoxy flows inside the cavity channel, macro voids can form inside it. Therefore, in this study, the free-surface flow of the mold filling procedure was analyzed numerically by applying the VOF method. The results were used to understand the phenomena of void formation inside the cavity and to modify the process conditions to reduce voids.

Investigation of Sound Pressure Detection of Fiber Optic Sensor in Transformer Oil According to TLS and CW Laser Source (TLS와 CW 광원에 따른 트랜스포머 오일 내에서 광섬유 센서의 음압 감지 특성 연구)

  • Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • To substitute TLS in the hybrid system which is combined with Sagnac interferometer and fiber bragg grating (FBG) it is necessary to investigate how the laser source (TLS and CW) and sensor material variate the response of fiber optic sensor. Two different hollow cylinder type mandrel materials are proposed which are PTFE and PTFE+carbon and 18 m optical fiber is wounded at the mandrel surface. CW laser source experiments had been done in the oil tank which is filled with transformer oil in the 1 kHz~20 kHz frequency range. Also Sagnac interferometer fiber optic sensor is combined with FBG called hybrid system and TLS used as a light source. Based on the experimental results PTFE sensor showed more higher magnitude of detection signal rather than carbon sensor and this result is agreement with the McMahon's theoretical results. Phase variation is inversely proportional to the elastic modulus of the mandrel material. In PTFE fiber sensor, tunable laser source showed more higher performance rather than CW case. Therefore, TLS fiber optic sensor can be applied to the hybrid system which is combined with Sagnac and FBG.

Fabrication of Pd/NiCr gate MISFET sensor for detecting hydrogen dissolved in Oil. (유중 용존수소 감지를 위한 Pd/NiCr 게이트 MISFET 센서의 제작)

  • Kim, Gop-Sick;Lee, Jae-Gon;Hahm, Sung-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.221-227
    • /
    • 1997
  • The Pd/NiCr gate MISFET-type sensors were fabricated for detecting hydrogen dissolved in high-capacivity transformer oil. To improve stability and high concentration sensitivity of the sensor, Pd/NiCr double catalysis metal gate was used. To reduce the serious gate voltage drift of the sensor induced by hydrogen, the gate insulators of 2 FETs were constructed with double layer of silicon dioxide and silicon nitride. The hydrogen sensitivity of the Pd/NiCr gate MISFET is about a half of Pd/Pt gate MISFET's sensitivity but the Pd/NiCr gate MISFET has good stability and high concentration detectivity up to 1000 ppm.

  • PDF

Analysis for Correlation Between Furfural and CO, CO2 Gas Dissolved Inside Insulating Oil using Linear Regression Method (선형회귀법을 이용한 절연유에 용존된 furfural과 CO, CO2 가스 함유량 간의 상관관계 분석)

  • Kim, Jae-Hoon;Park, Doo-Gie;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.212-217
    • /
    • 2010
  • When paper which was applied as insulation in oil-filled transformer was aged by thermal, its electrical, mechanical and chemical characteristics were changed and deteriorated. Therefore operating temperature was more higher, damage of paper was more quicker. Insulating paper which was generally made with cellulose was degraded, polymer of long length chain was decomposed as a monomer and CO, $CO_2$ gas and/or by-product such as furfural was produced from paper at the same time. In according with detection these gas and furfural by dissolved gas analysis(DGA) and high performance liquid chromatography(HPLC), we have investigated effects of CO, $CO_2$ gas and furfural on insulation of paper. Also we have analyzed for correlation between furfural and CO, $CO_2$ gas using linear regression method that was known as useful, credible statistical analysis.

Simulation of Transformer Oil Streaming for On-Line Gas in Oil Detector (온라인 유중가스 측정기에 대한 절연유 유동해석)

  • Chin, S.B.;Kweon, D.J.;Shim, E.B.;Woo, J.W.;Eo, S.Y.;Choi, G.B.;Kim, S.T.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1762-1764
    • /
    • 2003
  • 변압기의 이상 징후를 조기에 검출하여 사고를 미연에 방지하기 위해 설치된 예방진단시스템은 현재 국내 9개 변전소에서 운영되고 있다. 이러한 예방진단시스템의 적극적인 활용을 위해서는 시스템을 구성하는 각 요소에 대한 신뢰성 검증과 주기적인 점검, 축적된 데이터의 분석을 통한 사고예방 검출 사례의 축적이 요구되고 있다. 변압기 예방진단시스템의 가장 중요한 항목인 유중가스 측정기는 변압기 드레인 밸브에 설치됨에 따라, 변압기 내부 절연유가 유중가스 측정기로 유동되는지에 대한 의문이 존재하여 왔다. 본 논문에서는 유동해석 프로그램인 Fluent 5.3과 Gambit 프로그램을 이용하여, 변압기 내부의 열에 의한 대류현상에 의해 순환하는 절연유가 좁은 파이프를 통하여 유중가스 측정기의 삼투막까지 도달하는 유동현상을 해석하였다. 유동해석 결과 절연유가 삼투막과 만나는 지점에서도 절연유의 유동에 의한 순환이 발생하여, 용존가스의 검출이 가능함을 알 수 있었다.

  • PDF

A study on the oil transformer diagnostic technology using injection type UHF PD sensor (주입식 UHF PD 센서를 이용한 유입식 변압기 진단 기술 연구)

  • Kang, W.J.;Lee, C.J.;Kang, Y.S.;Park, J.B.;Lee, H.C.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1891-1893
    • /
    • 2004
  • 이 논무에서는 유입식 변압를 대상으로 UHF 대역의 펄스신호를 검출하는 센서를 소개하고, 이를 이용한 방전 결함별 측정 결과를 소개한다. 측정결과는 기존의 PRPD법과 주파수 Domain과 위상 Domain에 대한 정보를 가지는 p-f-q 분석으로 측정 하였으며, 본 논문에서는 후자의 결과를 중심으로 서술 하였다.

  • PDF

UHF PD Systems of LGIS (LG산전 UHF 부분방전 시스템)

  • Lee, Chang-Jun;Lee, Hee-Cheoul;Park, Jong-Wha;Kang, Won-Jong;Kang, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1888-1890
    • /
    • 2004
  • 현대사회에 들어서면서, 전력수요의 중가와 전력기기산업의 고집적화에 따라 사고시에 발생하는 파급효과가 대형화되는 추세에 있다. 따라서 이를 미연에 방지하기 위한 연구가 각 분야에 걸쳐 활발하게 진행되고 있다. 이에 당사에서는 초고압 계통에서 사용되는 SF6가스 절연 GIS(Gas Insulated Switchgear) 및 Oil-Transformer에서의 부분방전 측정/분석을 위하여 UHF/AE를 이용한 on-line/portable 측정 시스템을 개발하였다. 본 논문에서는 개발/상용화 되어 field에서 사용되고 있는 시스템의 전반에 대하여 설명한다. 또한 철재 선진사와 공동 진행중인 Risk Assessment에 대하여 언급하였다.

  • PDF

Technical road map for monitoring and diagnosis of oil immersed transformer (유입식변압기 감시진단 기술로드맵)

  • Sun, J.H.;Yi, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.13-15
    • /
    • 2005
  • 본 연구에서는 진단연구회에서 게획중인 유입식변압기의 감시진단기술에 관한 로드맵을 설명하고 있다. 유입식변압기의 용량 및 절연기술의 변천과 최근의 절연유 및 고체절연물, 변압기설계기술 연구동향에 대하여 설명하였다. 또한 변압기의 열화기구 및 현재의 감시진단 기술분석을 통한 기술로드맵을 작성하였다. 기술로드맵에서는 유입식변압기의 고장을 신뢰성 있고 효율적으로 수행할 수 있는 센싱기술, 신호처리기술, 데이터분석기술, 장치개발기술 등을 기술하였다.

  • PDF

Dissolved Gas Analysis Interpretation System for Power Transformers using Statical Fuzzy Function (통계적 퍼지 함수를 이용한 전력용 변압기 유중가스 판정 시스템)

  • Cho, Sung-Min;Kim, Jae-Chul;Shin, Hee-Sang;Kweon, Dong-Jin;Koo, Kyo-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.275-278
    • /
    • 2007
  • Dissolved gases analysis (DGA) is one of the most useful techniques to detect incipient faults in power transformers. Criteria interpreting DGA result is the most important. Because of difference of operation environment, construction type, oil volume, and etc, the interpretative criteria of DGA at KEPCO must be different with other standard like IEC-60599, Rogers and Doernenburg. In this paper, we collected the DGA data of the normal condition transformers and the incipient fault transformer to suggest the most appropriate criteria. Using these data, this paper suggests appropriate condition classification algorithm. Suggested algorithm can help to detect incipient fault earlier without unnecessary sampling.