• 제목/요약/키워드: Transformer Oil

검색결과 400건 처리시간 0.041초

전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발 (Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor)

  • 김주한;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF

Imaging of Magnetic Nanoparticles Added in Transformer Oil According to the Electric and Magnetic Fields

  • 이종철;이상엽
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.219-220
    • /
    • 2013
  • The phenomenology of liquid breakdown has been an area of interest for many years but is still not fully understood. Moreover, it was known that the behavior of magnetic nanoparticles in transformer oil could affect the dielectric breakdown voltage positively or negatively. In this study, we have imaged the magnetic nanoparticles in a transformer oil in-situ using an optical microscopic set-up and a microchannel according to the electric and magnetic fields applied. And we have calculated numerically dielectrophoresis and magnetophoresis forces, which must be the driving mechanisms to move magnetic nanoparticles in the fluid. It was found that when the electric field is applied the magnetic nanoparticles in the fluid experience an electrical force directed toward the place of maximum electric field strength. And when the external magnetic field is applied, the magnetic nanoparticles form long chains oriented along the direction of the field.

  • PDF

지하철 유입 변압기의 FN 선도를 이용한 위험도 평가 연구 (A Study on the Risk Assessment for Oil Immersed Transformer of Subway with FN curve)

  • 최승혁;이종우
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1152-1158
    • /
    • 2014
  • In Modern society, various important systems is operated such as nuclear plant, chemistry industry, railway system and so on. But these systems can cause high risky accidents. Hence, these systems are required to ensure the individual and societal risk criteria. In this paper, we reviewed EU risk criteria which is already operated in UK and Netherlands, then we proposed acceptable risk criteria and estimated risk of oil immersed transformer for subway with FN curve.

방열기를 갖는 유입자냉식 변압기의 온도분포 해석 (Ana1ysis of Temperature Distribution in Oil-immersed Self-cooled Transformer with Radiator)

  • 김중경;한성진;오연호;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.755-756
    • /
    • 2006
  • This paper presents the temperature distribution of the oil-immersed self-cooled transformer with radiator performed by coupled magneto-fluid-thermal analysis. Particularly, 3D temperature distribution of cooling oil and sub-components under the natural convection is obtained by computational fluid dynamics analysis, while heat sources are predetermined by magnetic field analysis using F.E.M. The predicted temperature distribution of the power transformer model is compared with the measured data for verifying the validity of the proposed analysis.

  • PDF

주상변압기 절연유의 경년열화반응 속도론에 관한 연구 (A Study on the Age Degradation Kinetics of Pole Transformer Oil)

  • 남영우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.99-105
    • /
    • 1997
  • 본 논문에서는 주상변압기 절연유의 가속열화반응을 수행하였다. 유중가스를 air bubbling 법으로 추출하여 가스크로마토크라프로 성분을 분석하였으며 가스농도는 각 가스의 추출율을 감안하여 보정하였다. 절연재료의 열화는 열분해반응과산화반응에의하여 진행되었으며 두 종류의 반응은 모두 0차반응의 특성을 보였고 탄화수소류, CO+{{{{ { CO}_{2 } }}}} 및 수소가스의 생성속도식을 얻었다. 유중가스 분석과 UV-Visible 분광광도법에 의하여 변압기내의 철심과 동코일이 열화과정에서 촉매역활을 함을 확인하였다.

  • PDF

대두유 에스테르계 절연유의 합성과 분석 (Study on the synthesis and characterization of soybean based transformer oils)

  • 한동희;조한구;한세원;안명상;오대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.244-245
    • /
    • 2005
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions of soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. The thermal stability of the esters was determined by thermal gravimetric analysis(TGA).

  • PDF

초전도변압기의 계통적용을 위한 예상 시장진입가격 추정 (Evaluate the expected price of HTS transformer for introducing into korean power system)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.176-178
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated, which HTS transformer is competitive against conventional transformer.

  • PDF

154kV 방재형 난연 변압기 냉각특성에 관한 연구 (A Study on the Cooling Characteristic of a 154kV Less-Flammable Power Transformer)

  • 박정호;오원근;하영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.61-64
    • /
    • 2001
  • Demand for development of 154kV Less-Flammable Power transformer is now increasing greatly instead of a oil-immersed transformer for preventing disasters and Less-flammability of substations. The most important point in developing Less-flammable transformer is cooling system. This paper describes the study on cooling characteristic of Less-flammable transformer.

  • PDF

변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구 (Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer)

  • 김국겸;서용권;강상모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.449-455
    • /
    • 2015
  • 전력용 변압기 용량의 증대와 고효율화에 따른 권선의 단위체적당 열발생량의 증가 및 이에 따른 절연성능의 저하는 전력용 변압기의 수명과 신뢰성에 큰 영향을 준다. 이러한 문제점은 방열기의 냉각성능을 증가시킴으로써 해결이 가능하다. 본 연구는 ONAF(Oil Natural Air Forced) 형식의 변압기의 방열기에 대해 공기의 강제대류를 일으키는 팬의 위치에 따른 냉각성능 평가를 통하여 냉각효과가 가장 큰 팬의 위치를 찾기 위한 것이다. 해석에는 유동해석 상용소프트웨어를 사용하였으며, 해석시간의 단축을 위하여 오일의 냉각유로를 단순화시켰고 팬의 지름을 일정하게 두고 팬의 위치를 다양하게 변화시켜가며 해석을 실행하였다. 해석 결과 팬의 수직적인 위치 변화는 냉각성능에 크게 영향을 주지 않았으나 팬이 변압기의 전방영역에 위치할 경우 후방영역의 배치보다 온도강하가 큰 것을 확인할 수 있었다.

Detection and Location of Partial Discharge in Oil Filled Transformer

  • Lee, Seung-Whan;Oh, Hak-Joon;Chung, Chan-Soo;Yun, Man-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.98.3-98
    • /
    • 2001
  • The research for detecting of insulating deterioration in transformer has been studied from long ago. Analysis method of combustible gas, which is included in insulating oil, has been widely used in detection of transformer pre-fault detection due to the effectiveness of its method. Recently the fault effect of the large transformer is very critical in a power system, therefore the on-line monitoring and diagnostic system is needed. In addition, the more accurate method of detecting a Partial Discharge (PD) location should be developed. For preventive maintenance against discharge failures, it is important not only to detect the discharges, but also to accurately estimate their positions. However ...

  • PDF