• 제목/요약/키워드: Transformer Load Pattern

검색결과 17건 처리시간 0.019초

수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준 (Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers)

  • 윤상윤;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

변압기 부하패턴 분석을 위한 시간 데이터마이닝 연구 (Study of Temporal Data Mining for Transformer Load Pattern Analysis)

  • 신진호;이봉재;김영일;이헌규;류근호
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1916-1921
    • /
    • 2008
  • This paper presents the temporal classification method based on data mining techniques for discovering knowledge from measured load patterns of distribution transformers. Since the power load patterns have time-varying characteristics and very different patterns according to the hour, time, day and week and so on, it gives rise to the uninformative results if only traditional data mining is used. Therefore, we propose a temporal classification rule for analyzing and forecasting transformer load patterns. The main tasks include the load pattern mining framework and the calendar-based expression using temporal association rule and 3-dimensional cube mining to discover load patterns in multiple time granularities.

데이터베이스를 이용한 부하패턴별 수용가 특징 모델링 (Customer Characteristics Modeling for Each Load Pattern using the Database)

  • 이영석;김재철;오정환;윤상윤;박창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.416-418
    • /
    • 2001
  • This Paper presents the 2-step load cycle of daily load curve for representative load pattern of power distribution transformer. We decide the representative load pattern of distribution transformer in domestic using the pattern classification algorithm. The K-mean method is used for the pattern classification algorithm. The acquisition equipment of field load data is utilized for 96-sample distribution transformers and the field data is used in the construction of the database for the creation of daily load pattern.

  • PDF

배전용 변압기 부하사용 패턴분류 (Pattern Classification of Load Demand for Distribution Transformer)

  • 윤상윤;김재철;이영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.89-91
    • /
    • 2001
  • This paper presents the result of pattern classification of load demand for distribution transformer in domestic. The field data of load demand is measured using the load acquisition device and the measurement data is used for the database system for load management of distribution transformed. For the pattern classification, the load data and the customer information data are also used. The K-MEAN method is used for the pattern classification algorithm. The result of pattern classification is used for the 2-step format of load demand curve.

  • PDF

패턴 클러스터링 기법에 기반한 배전 변전소 주변압기 사고복구 전략 설계 (Design of Main Transformer Fault Restoration Strategy Based on Pattern Clustering Method in Automated Substation)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.410-417
    • /
    • 2006
  • Generally, the training set of maximum $m{\times}L(m+f)$ patterns in the pattern recognition method is required for the real-time bus reconfiguration strategy when a main transformer fault occurs in the distribution substation. Accordingly, to make the application of pattern recognition method possible, the size of the training set must be reduced as efficient level. This Paper proposes a methodology which obtains the minimized training set by applying the pattern clustering method to load patterns of the main transformers and feeders during selected period and to obtain bus reconfiguration strategy based on it. The MaxMin distance clustering algorithm is adopted as the pattern clustering method. The proposed method reduces greatly the number of load patterns to be trained and obtain the satisfactory pattern matching success rate because that it generates the typical pattern clusters by appling the pattern clustering method to load patterns of the main transformers and feeders during selected period. The proposed strategy is designed and implemented in Visual C++ MFC. Finally, availability and accuracy of the proposed methodology and the design is verified from diversity simulation reviews for typical distribution substation.

100kVA 이하급 배전용 변압기 일부하 패턴의 2-Step 모델링 (2-Step Modeling for Daily Load Curve of Up to and Including 100kVA Distribution Transformer)

  • 이영석;김재철;윤상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.371-373
    • /
    • 2001
  • In this paper, we present 2-step load cycle for daily load curve of up to and including 100kVA distribution transformer in domestic. Daily load patterns are classified by two methods dependent upon possession information. In case we possess daily load profiles make use of K-mean algorithm and in case we have not daily load profiles, make use of customer information of KEPCO. As the parameters of the load pattern classification, we use are daily load profiles and customer information of each distribution transformers. Data management system is used for NT oracle. We can present peak load magnitude, initial load magnitude and peak load duration for daily load patterns by 2-step load cycle for daily load curve of up to and including 100kVA distribution transformer in domestic. We think that this paper contributes to enhancing the distribution transformer overload criterion.

  • PDF

자동화된 변전소의 주변압기 사고복구를 위한 패턴인식기법에 기반한 실시간 모선재구성 전략 개발 (Real-Time Bus Reconfiguration Strategy for the Fault Restoration of Main Transformer Based on Pattern Recognition Method)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.596-603
    • /
    • 2004
  • This paper proposes an expert system based on the pattern recognition method which can enhance the accuracy and effectiveness of real-time bus reconfiguration strategy for the transfer of faulted load when a main transformer fault occurs in the automated substation. The minimum distance classification method is adopted as the pattern recognition method of expert system. The training pattern set is designed MTr by MTr to minimize the searching time for target load pattern which is similar to the real-time load pattern. But the control pattern set, which is required to determine the corresponding bus reconfiguration strategy to these trained load pattern set is designed as one table by considering the efficiency of knowledge base design because its size is small. The training load pattern generator based on load level and the training load pattern generator based on load profile are designed, which are can reduce the size of each training pattern set from max L/sup (m+f)/ to the size of effective level. Here, L is the number of load level, m and f are the number of main transformers and the number of feeders. The one reduces the number of trained load pattern by setting the sawmiller patterns to a same pattern, the other reduces by considering only load pattern while the given period. And control pattern generator based on exhaustive search method with breadth-limit is designed, which generates the corresponding bus reconfiguration strategy to these trained load pattern set. The inference engine of the expert system and the substation database and knowledge base is implemented in MFC function of Visual C++ Finally, the performance and effectiveness of the proposed expert system is verified by comparing the best-first search solution and pattern recognition solution based on diversity event simulations for typical distribution substation.

주상변압기 부하 상관식 조정에 관한 실증적 연구 (Practical Study on Adjustment of Load Correlation Equations of Pole Transformer)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.102-108
    • /
    • 2000
  • 본 논문은 주상변압기의 부하관리를 위한 부하 상관식 조정에 관한 실증적 연구 결과를 제시하였다. 부하 상관식 조정을 위하여 주상 변압기의 사용전력량[kWh]과 최대 부하[A] 사이의 상관 관계를 분석하였다. 또한 상관식의 정확성을 높이기 위하여 12개의 지역 패턴으로 분류하였다. 그리고 각 지역 패턴에 24개씩의 표본 주상 변압기를 선정하였다. 부하 상관식에 사용된 데이터의 신뢰성을 위하여 표본 주상변압기에 부하관리기를 설치하였다. 온-라인 데이터 취득을 통하여, 데이터 베이스를 구축하였다. 부하 상관식 조정에 있어서 본 논문에서는 두 부분에 대해 고려를 하였다. 그중 하나는 부하 상관식의 적합성 또 하나는 과부하로 인한 주상변압기 손실 방지이다. 최종적으로 1, 2차 상관함수를 병용하는 상관식올 제안하였다. 또한 사례 연구를 통하여 제안한 부하 상관식이 기존에 사용하는 상관식 보다 오차 비율이 감소했음을 입증하였다.

  • PDF

디스크형 압전변압기의 전극비에 따른 전기적 특성 (A Electrical Characteristics of Disk-type Piezotransformer with Electrode Ratio of Driving and Generating Part)

  • 이종필;채홍인;정수현;홍진웅
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.458-463
    • /
    • 2003
  • In order to develope piezoelectric transformer for the ballast of fluorescent lamp, a new shape and electrode pattern of piezoelectric transformer has been investigated in this work. The composition of piezoelectric ceramics was 0.95Pb(Zr$_{0.51}$Ti$_{0.49}$)O$_3$+0.03Pb(Mn$_{1}$3/Nb$_{2}$3/)O$_3$+0.02Pb(Sb$_{1}$2/Nb$_{1}$2/)O$_3$. The sample prepared by this composition system showed the characteristics which has about 1200 of relative dielecric constant, 1100 of the mechanical quality factor, 0.53 of the electromechanical coupling coefficient, 320 pC/N of the piezoelectric constant d$_{33}$, 0.3 % of the dissipation factor. Diameter and thickness of disk-type piezoelectric transformer was 45 mm and 4 mm, respectively. The driving and generating electrode with their gap of 1mm were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface ranges from 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of the electrode surface ratio of driving and generating part in the range of load resistance of 100 $\Omega$~70 k$\Omega$. The set-up voltage ratio of this piezoelectric transformer increases with increasing both the electrode surface of driving part and the load resistance. The set-up voltage ratio at no load resistance was more than 60 times. On the other hand, the efficiency decreases with increasing the electrode surface of driving part. In the case of the electrode surface of both 1.4:1 and 2:1, maximum efficiency showed above 97 % at load resistance of 2 k$\Omega$. However, in the case of the electrode surface of 3:1, maximum efficiency showed about 94 % at load resistance of 3 k$\Omega$.>.>.>.

디스크형 압전 변압기 의 전극크기 변화에 대한 전기적 특성 (Electric Characteristics of Disk-type Piezoelectric Transformer)

  • 김동수;김영덕;김광일;도영수;남성진;남효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.226-229
    • /
    • 2005
  • In this study, a step-down piezoelectric transformer was fabricated to utilize as an adapter for charging batteries of mobile electronic appliances. The ceramic part of the transformer is $Pb[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_{0.475}Ti_{0.475}]O_3$ with mechanical quality factor of 1600, electromechanical coupling coefficient 59 %, and piezoelectric constant d33 1300, which can be utilized as a piezoelectric transformer. A simply fabricated disk-typed test pattern of diameter 28 mm and thickness 2 mm was used to characterize resonant frequency, Qm, kp according to the different input/output electrode area. efficiency and power as a function of load resistance was also investigated. The sample APT showed some spurious mode and BPT showed better frequency property. Taking all properties which are admittance, effective electromechanical coupling coefficient and mechanical quality factor most suitable for piezoelectric transformer is BPT which has 12 mm diameter electrode and the condition of 15 Vrms, 30 $\Omega$ made the maximum efficiency of 93.7 % and maximum power is 6W with 50 Vrms.

  • PDF