• 제목/요약/키워드: Transformer Design

검색결과 895건 처리시간 0.037초

예방진단센서가 내장된 옥외용 ECT의 전계분포특성 (The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor)

  • 이한주;조성훈;정의환;윤재훈;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

마이크로프로세서를 이용한 3상 브리지 콘버터의 제어회로 설계에 관한 연구 (A Study on the Design of a Control Circuit for Three- Phase Full Bridge Converter Using Microprocessor)

  • 노창주;김윤식;김영길;유진열;류승각
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권4호
    • /
    • pp.102-112
    • /
    • 1992
  • The three-phase full(6-pulse) bridge controlled rectifier is one of the most widely used types of solid-state converters in DC drive applications for higher performance. In most of the previous designs, the gate control circuits of the converter have been designed with analog method which can be easily affected by noise. Nowdays with advances of microelectronics and power electronics, microprocessor and pheripal LSIs are increasingly used for eliminating this problems. In this paper, a novel general-purpose microprocessor -based firing system and control scheme for a three-phase controlled rectifier bridge has been developed and tested. Using the phase relations between ${\Delta}$-Y transformer in power operation part, gate pulse of the converter is generated with real time process so that microprocessor may share its time to control algorithms efficiently. The firing angle of the converter is smoothly controlled in the range of 0 $^{\dirc}$ to 180$^{\dirc}$ with a fast respone and a constant open loop gain, even for the case where the converter is fed by a weak AC system of unregulated frequency. The hardware and software control circuit implementation built around a 80286 microprocessor is discussed, and the experimental results are given. This scheme uses less hardware components and has higher dynamic performance in variable speed DC drive applications.

  • PDF

Short-circuit Analysis by the Application of Control Signal of Power Converter to the Inductive Fault Current Limiter

  • Ahn, Min-Cheol;Hyoungku Kang;Bae, Duck-Kweon;Minseok Joo;Park, Dong-Keun;Lee, Sang-Jin;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.25-28
    • /
    • 2004
  • Three-phase inductive superconducting fault current limiter (SFCL) with DC reactor rated on 6.6 $KV_{rms}/200 A_{rms}$ has been developed in Korea. This system consists of one DC reactor, AC/DC power converter, and a three-phase transformer, which is called magnetic core reactor (MCR). This paper deals with the short-circuit analysis of the SFCL. The DC reactor was the HTS solenoid coil whose inductance was 84mH. The power converter was performed as the dual-mode operation for dividing voltage between the rectifying devices. The short-term normal operation (1 see) and short-circuit tests (2∼3 cycles) of this SFCL were performed successfully. In regular short-circuit test, the fault current was limited as 30% of rated short-circuit current at 2 cycles after the fault. The experimental results have a very similar tendency to the simulation results. Using the technique for the fault detection and SCR firing control, the fault current limiting rate of the SFCL was improved. From this research, the parameters for design and manufacture of large-scale SFCL were obtained.

극초고압 변압기 주권선부 절연설계 개선 연구 (Study on the Insulation Design Improvement in the Main Winding of an Ultra-high Voltage Power Transformer)

  • 이찬주;석복렬;김용한;김동해;허종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.802-803
    • /
    • 2008
  • 본 연구에서는 변압기의 권선간 전계 및 절연안전율 예측알고리즘을 개발하였으며, 이를 활용하여 극초고압 변압기의 절연구조개선 연구를 수행하였다. 개발된 알고리즘을 사용하면 한 번의 기본모델의 수치해석 결과만을 이용하여 다양한 권선간 거리 및 고체절연물의 개수 변화에 따른 전계 및 절연안전율의 예측이 가능하다. 본 알고리즘을 극초고압 변압기 주권선부 개선에 적용시킨 결과, 권선간 고체 절연물 개수를 조절하면 절연신뢰성 저하없이 주권선부 거리를 단축시킬 수 있음을 확인하였다. 또한, 본 예측 알고리즘의 활용가능성을 검증하고자 개선 모델의 절연안전율을 수치해석적 방법으로 계산하여 이를 예측 결과와 비교하였다. 그 결과, 본 예측 알고리즘으로 계산된 결과는 수치해석적 방법에 의한 결과에 비해 약 $1{\sim}2%$ 정도의 작은 차이가 발생하는 것으로 확인되었다. 따라서 본 연구를 통하여 개발된 전계분포 및 절연안전율 예측기법을 실제 설계에 적용할 수 있을 것으로 판단된다.

  • PDF

Characteristics of Optical Current Sensors by Sensor Design

  • Kim, Young-Min;Park, Jung-Hwan;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.80-87
    • /
    • 2007
  • This paper will suggest that the 1 cross orthogonal loop type sensor improves on the orthogonal loop form sensor-head, which is available a calibration of the linear birefringence, when a fiber optic current sensor was composed. An output characteristics of the 1 cross orthogonal loop form, a general closed loop form, the orthogonal loop form are compared by the IEC(International Electrotechnical Commission) 60044-8 standard, and the state of polarization is compared with three forms. As a result, when the closed loop form was changed to the orthogonal loop form, retardation decreased 15.3[%]. When the closed loop form was changed to the 1 cross orthogonal loop type, the retardation decreased 33.8[%]. As a result of the Faraday Effect measurement, the 1 cross orthogonal loop form has the highest output characteristic and the lowest error ratio. It met the 0.5 class of the IEC 60044-8 standard. Thus, in application of the 1cross orthogonal loop form, the possibility to develop high reliability fiber optic current sensors that have a high output and stable error ratio rises is increased.

균일한 임피던스 전송선로 길이 조정을 통한 비대칭 Bagley 분배기 (Unequal Bagley Divider based on Uniform Characteristic Impedance Transmission Lines with Adjustment Electrical Lengths)

  • 윤영철;홍성욱;김영
    • 한국항행학회논문지
    • /
    • 제21권3호
    • /
    • pp.287-293
    • /
    • 2017
  • 본 논문은 균일한 임피던스를 갖는 출력 포트사이 전송선로의 전기적 길이를 다르게 함으로서 비대칭 Bagley 분배기 설계에 대한 내용을 서술하였다. 이 분배기는 입력 포트와 연결된 출력 포트의 전기적 길이만을 조정하여 출력 포트에 원하는 임의의 출력 비율을 얻을 수 있고, 모든 전송선로의 특성 임피던스는 균일한 것이 특징이다. 이러한 설계 방법을 사용하면 비대칭 출력을 얻을 수 있음에도 출력포트에는 임피던스 변환기를 사용하지 않는다. 이것을 증명하기 위해서 동작주파수 2 GHz에서 1:2:1 비율의 3차와 2:3:4:3:2 비율의 5차 비대칭 Bagley 분배기를 시뮬레이션과 제작하였다. 측정 결과는 시뮬레이션과 동일함을 확인하였다.

Bidirectional Power Conversion of Isolated Switched-Capacitor Topology for Photovoltaic Differential Power Processors

  • Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1629-1638
    • /
    • 2016
  • Differential power processing (DPP) systems are among the most effective architectures for photovoltaic (PV) power systems because they are highly efficient as a result of their distributed local maximum power point tracking ability, which allows the fractional processing of the total generated power. However, DPP systems require a high-efficiency, high step-up/down bidirectional converter with broad operating ranges and galvanic isolation. This study proposes a single, magnetic, high-efficiency, high step-up/down bidirectional DC-DC converter. The proposed converter is composed of a bidirectional flyback and a bidirectional isolated switched-capacitor cell, which are competitively cheap. The output terminals of the flyback converter and switched-capacitor cell are connected in series to obtain the voltage step-up. In the reverse power flow, the converter reciprocally operates with high efficiency across a broad operating range because it uses hard switching instead of soft switching. The proposed topology achieves a genuine on-off interleaved energy transfer at the transformer core and windings, thus providing an excellent utilization ratio. The dynamic characteristics of the converter are analyzed for the controller design. Finally, a 240 W hardware prototype is constructed to demonstrate the operation of the bidirectional converter under a current feedback control loop. To improve the efficiency of a PV system, the maximum power point tracking method is applied to the proposed converter.

대기전력저감을 위한 플라이백컨버터 (A Novel Flyback Converter for Low Standby Power Consumption)

  • 정봉근;장상호;김은수;최문기;계문호
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.299-306
    • /
    • 2009
  • 최근 대기전력저감기능을 갖는 PWM IC를 적용한 플라이백 컨버터는 대기전력 모드 시 Burst 스위칭 동작에 의해 전력소모를 최소화 할 수 있지만 경 부하 및 대기전력모드 시 변압기를 통해 흐르는 큰 자화전류에 의해 여전히 낮은 효율특성을 가지는 문제점이 있었다. 본 논문에서는 경 부하 및 대기전력모드 동작 시 자화전류를 최 소화함으로 효율을 개선한 회로를 제안하였으며 50인치 PDP TV PSU (Power Supply Unit)에 있어서 대기전력 및 보조전원으로 사용된 70W 플라이백 컨버터에 적용 실험하여 보았다.

적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정 (Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry)

  • 박명진;임형우;이광연;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

TFT-LCD 모니터용 대출력 인버터설계와 적층형 압전 변압기 제작 (Design of the Backlight Inverter for Large TFT-LCD Monitor & Manufacture of Multilayer Piezoelectric Transformer)

  • 한재현;임영철;양승학;권기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.158-163
    • /
    • 2002
  • 최근 전자통신기기의 급속화된 발전과 함께 전자부품에 대한 초소형화, 고성능화가 요구되고 있다. 특히 노트북 컴퓨터나, PDA, LCD 모니터와 같이 박막 액정 표시장치(Thin Film Transistor Liquid Crystal Display, TFT-LCD)가 대표적인 예라 볼 수 있다. 이러한 박막 액정 표시장치는 그 내부에 냉음극 형광램프(Cold Cathode Fluroscent Lamp)가 있어서 백라이트의 역할을 하는데 냉음극 형광램프의 특성상 초기 고압의 구동전압을 인가시킬 수 있는 인버터가 필수적이라 하겠다. 본 논문에서는 18인치(4_CCFL), 20인치(6_CCFL) TFT-LCD 모니터용, 멀티램프 구동 인버터를 설계 제작하여 90%에 가까운 효율을 얻었다. 코일손실 및 전자유도의 장애가 없고 불연성의 장점을 가지고, 소형화가 가능한 적층형 압전 변압기를 제작하고 이 제작된 적층형 압전 변압기의 전기적 특성분석을 통한 방전램프 구동용 인버터의 승압용 변압기로써 적용이 가능함을 확인하였다.

  • PDF