• Title/Summary/Keyword: Transfer-in

Search Result 25,802, Processing Time 0.042 seconds

Associations of post-warming embryo or blastocyst development with clinical pregnancy in vitrified embryo or blastocyst transfer cycles

  • Hong, Yeon Hee;Lee, Jang Mi;Kim, Seul Ki;Youm, Hye Won;Jee, Byung Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.47 no.2
    • /
    • pp.140-146
    • /
    • 2020
  • Objective: To investigate whether the degree of post-warming embryo or blastocyst development is associated with clinical pregnancy in vitrified embryo or blastocyst transfer cycles. Methods: Ninety-six vitrified cleavage-stage embryos and 58 vitrified blastocyst transfer cycles were selected. All transfer cycles were performed from February 2011 to March 2019, and all vitrified embryos or blastocysts were warmed from 4 PM to 6 PM and then transferred the next morning from 9 AM to 10 AM. The scores of the cleavage-stage embryos and blastocysts were assessed at warming and at transfer using the modified Steer method and the Gardner method, respectively. The mean embryo or blastocyst score, score of the single top-quality embryo or blastocyst, and the difference in the score between warming and transfer were compared between nonpregnant and pregnant women. Results: In the cleavage-stage embryo transfer cycles, both the top-quality embryo score at transfer and the difference in the score between warming and transfer were significantly associated with clinical pregnancy. A top-quality embryo score at transfer of ≥ 60.0 (area under the curve [AUC], 0.673; 95% confidence interval [CI], 0.531-0.815) and a difference in the score between warming and transfer of ≥ 23.0 (AUC, 0.675; 95% CI, 0.514-0.835) were significant predictors of clinical pregnancy. In blastocyst transfer cycles, the top-quality blastocyst score at transfer was the only significant factor associated with clinical pregnancy. A top-quality blastocyst score at transfer of ≥ 38.3 was a significant predictor of clinical pregnancy (AUC, 0.666; 95% CI, 0.525-0.807). Conclusion: The top-quality embryo score at transfer and the degree of post-warming embryo development were associated with clinical pregnancy in vitrified cleavage-stage embryo transfer cycles. In vitrified blastocyst transfer cycles, the top-quality blastocyst score at transfer was the only significant factor affecting clinical pregnancy.

Experimental study on the characteristics of heat transfer for new type aluminum tube (신형 알루미늄관의 열전달 특성에 관한 실험적 연구)

  • 문춘근;윤정인;김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2000
  • This study investigated heat transfer characteristics of refrigeration system using new type aluminium heat transfer tube for evaporator of refrigeration and air-conditioning comparing with bare tube. From the result of heat transfer experiment form one phase flow using cooled and hot water, about 20% heat transfer performance is superior in case of same quantity of flow and about 4% heat transfer performance if superior in case of same velocity comparing with bare tube. Casing of two phase flow, heat transfer performance of new type aluminum heat transfer tube shows about 50% superior heat transfer performance comparing with bare tube in the same evaporating pressure when using heat transfer tube as evaporator and shows about 47% increase when expressing performance coefficient as the rate of refrigerating capacity and compressing work. However, it can be known that pressure drop in the heat transfer tube is taken higher value of about 18% in case of new type aluminum heat transfer tube. From the above result, new type aluminum heat transfer tube is excellent comparing with bare heat transfer tube using the existing heat exchanger for refrigerator.

  • PDF

Effect of Ca on Droplet Transfer Phenomena in GMA Welding (GMAW 용적이행 현상에 미치는 Ca의 영향)

  • 안영호;방국수;이종봉;장내웅
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.76-84
    • /
    • 1994
  • Droplet transfer modes due to welding conditions and the effect of Ca in welding wire on droplet transfer were investigated. Droplet transfer mode in CO$_{2}$ welding was classified into 2 modes, that is, short circuit and globular transfer, with increasing welding current and voltage. With increasing Ca content in wire, repulsive pressure due to vaporization of Ca was considerably increased. In short circuit transfer region, arcing time was increased and droplet transfer cycle was decreased, with increasing Ca content. In globular transfer region, welding condition for globular transfer was lower current region, with increasing Ca content.

  • PDF

An Evaluation of Transfer of Training Effects on Nuclear Power Plant MCR Operators

  • Kim, Jung Ho;Byun, Seong Nam
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Objective: The aim of this study sets factors from previous research known to impact transfer effects as the independent variables, and examines their relationship with the dependent variables, near transfer effects and far transfer effects. Background: Transfer of Training refers to the application of what learners acquire knowledge and skills in training programs to their job. The ultimate goal of training is to apply what employees learn in training sessions to their workplace. In this sense, transfer of training has been a vital concern for training effectiveness. For training to be effective, trainees(learners) should be able to use what they learn in training program back on the job. Method: For this research purpose, this study conducted a survey on 170 nuclear operators in nuclear education and training center. Of these, survey result from the 167 recruits were sampled. Theoretical model of this study is based on Holton & Baldwin's(2003) distance model of transfer effects. This study sets transfer effects(near transfer, far transfer) as the main dependent variables. Meanwhile, the independent variables are trainee characteristics, training characteristics, organizational transfer climate. Each independent variable has subordinate variables. Subordinate variables of trainee characteristics are self-efficacy, motivation to learn, motivation to transfer and ability to transfer. Subordinate variables of training characteristics are training contents, ability of trainers, training design, training climate. The last Subordinate variables of organizational transfer climate are support of supervisors, support of peer, support of organization. Conclusion: As a analysis result, trainee characteristics appeared to be in effect only significant influence near far transfer of training, the effect of the far transfer of training, there is no significant. In addition, the training characteristics appeared to be having a significant influence on near and far transfer effects. Organizational transfer climate appeared to be having a significant influence on near and far transfer effects. Finally, near transfer effect appeared to be having a significant influence on far transfer effects. Application: Results of this analysis in the study to training organization and training characteristics of the transition environment effects on nuclear power institutions and operators training organization having a significant impact that says. The transfer of knowledge and technology, as well as that can be applied to a new situation in terms of education and training are important characteristics.

A Study on the Transfer of Letter of Credit in the UCP600 - Focusing on Comparing with Transfer of drawing rights in the ISP98 - (신용장통일규칙(UCP600)상 양도에 관한 연구 - 보증신용장통일규칙(ISP98)과의 비교를 중심으로 -)

  • Park, Se-Hoon;Choi, Young-Joo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.53
    • /
    • pp.75-97
    • /
    • 2012
  • This study primarily concerns the transfer of letter of credit. A transferable credit is a credit that clearly specifies it is 'transferable' and may be made available in whole or in part to second beneficiary by the request of the first beneficiary. the transfer of the credit is available where the seller as a middleman in intermediate trades purchases from domestic and international supplier. The purpose of this study is to examine the transfer of letter of credit in the UCP600. Having recognized the differences, the study analyzes the transfer of letter of credit under the UCP600 in comparison to those under the ISP98. The ISP98, like the UCP600, stipulates for the requirement of transfer, the number of transfer, conditions of transfer, the replacement of the name of first beneficiary.

  • PDF

Configuration models for technology transfer from universities and research institutes to industries (대학 및 연구소와 산업계간 기술이전시스템의 구성 모델)

  • 문병근;조규갑
    • Proceedings of the Technology Innovation Conference
    • /
    • 2001.06a
    • /
    • pp.133-143
    • /
    • 2001
  • Technology transfer from universities and research institutes to industries is recognized as a critical issue to strengthen industrial competitiveness, and the roles of technology transfer intermediaries are becoming one of the most important factors for successful technology transfer In today's global and knowledge-based economies, technology transfer services are started shifting to Internet and vertical transfer of technology from R&D labs to industries is becoming more emphasized than horizontal company-to-company transfer of commercialized technology. And the need of comprehensive technology transfer services necessitates cooperation among technology transfer intermediaries and networks offering complementary services. In order to respond to these changes, it is required to construct a new type of technology transfer system. But there are few researches on technology transfer system configuration for design and realization of technology transfer intermediaries. This paper presents the configuration models of technology transfer from universities and research institutes to industries. The configuration models are classified and described from the viewpoint of flows of information, technology and knowledge.

  • PDF

Timed-Transfer of Buses (동시환승(Timed-Transfer) 버스시스템)

  • 고승영
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.4
    • /
    • pp.105-115
    • /
    • 1995
  • This paper deals with an operation concept of "time-transfer of buses", in which buses arrive a transfer center at the same time and allow passengers to transfer to other bus lines, so that passengerscan go anywhere all the timed-transfere buses operate with only one transfer. This timed-transfer bus system is known as an efficient operating technique which can be adopted in an area with sparsely distrubuted bus demand. A model of timed-transfer is estabilished in terms of vaious factors such as the expected(or average) arrival time, distribution of arrival time, timed-transfer cycle, shceduled departure time, etc. It is assumed that the objective of timed-transfer bus system is to minimize the total transfer waiting time. The optimal schedualed arrival time or buffer time(time required to arrive ealy in consideration of delay) is analyzed for a general case and various speicial cases. It was found that the optiaml buffer time is an inverse funcion of the timed-transfer cycl and increases with the cycle time, assumin g that there is a fixed scheduled departure time at the transfer cetner regardless of whether one or more buses fail to arrive before the scheduled departure time. If buses are to wait uhtil all the buses arrive at the transfer center, that is, the transfer departure time is vairable, the optimal scheduled arrival times can be obtained by a mathmatical programming.

  • PDF

A study on the Analogy between Heat Transfer and Mass Transfer (열전달과 물질전달의 유사성에 관한 연구)

  • 유성연;노종광;정문기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2624-2633
    • /
    • 1993
  • Mass transfer experiment by naphthalene sublimation method has great advantages in measurement of local transfer coefficients in the region of a three dimensional flow or for a model of complex geometry, which is considered to be very difficult with conventional heat transfer measurements. Mass transfer data obtained by naphthalene sublimation technique are converted to the heat transfer data through heat/mass transfer analogy. This analogy is valid for a simple or laminar flow, but new insight is needed when applying to a turbulent flow or complex flow such as separation, reattachment and recirculation, The purpose of this research is to investigate how geometries and flow conditions incorporate heat/mass transfer analogy. Mass transfer experiments are performed using naphthalene sublimation technique for a flat plate, a circular cylinder, and rectangular cylinders. And mass transfer data are compared with earlier heat transfer measurements for the same geometries. Usefulness of analogy relation between heat and mass transfer is examined with these results.

A Study on the Heat Transfer Perfomance of Dimpled Double Pipe Heat Exchanger on a Fuel Cell (연료전지용 딤플형 이중관열교환기의 열전달 성능에 관한 연구)

  • CHO, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1727-1733
    • /
    • 2015
  • In the present study, the heat transfer performance of dimpled double-pipe heat exchangers for fuel cells that are utilized as cooling systems of fuel cells was studied. In addition, to comparatively analyze the heat transfer performance of dimpled double-pipe heat exchanger for fuel cells, plain double-pipe heat exchangers were also studied. Experimental results were derived on changes in the Reynolds numbers of the cooling water flowing in dimpled and plain double-pipe heat exchangers and changes in the heat flux of the air. Thereafter, to verify the reliability of the experimental results, the theoretical overall heat transfer coefficients and the experimental overall heat transfer coefficients were comparatively analyzed and the following results were derived. The heat transfer rate lost by the hot air and that of the heat transfer rate obtained by the cooling water were well balanced. The experiments of plain double-pipe heat exchangers and dimpled double-pipe heat exchangers were conducted under normal conditions and the theoretical overall heat transfer coefficient and the experimental overall heat transfer coefficient coincided well with each other. In both plain double-pipe heat exchangers and dimpled double-pipe heat exchangers, heat transfer rates increased as the cooling water flow velocity increased. Under the same experimental conditions, the heat transfer performance of dimpled double-pipe heat exchangers was shown to be higher by 1.2 times than that of plain double-pipe heat exchangers.