• Title/Summary/Keyword: Transfer posture

Search Result 29, Processing Time 0.02 seconds

Development of Projectile Transfer System to Prevent Musculoskeletal Problems (근골격계 질환 예방을 위한 포탄 이송장치의 개발)

  • Park, Sung Ho;Lee, Hae Suk
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.6
    • /
    • pp.551-558
    • /
    • 2015
  • The purpose of this paper is to investigate the development of mechanical projectile transfer system to prevent musculoskeletal problems in the firing test range. Prior to 2010, the projectile has been transferred from the worktable to the loading device of 155mm K9 fixed-type artillery by manual. Because the amount of firing test has been increased drastically since 2010, two types of mechanical projectile transfer system were developed to prevent musculoskeletal problems. The NIOSH lift equation and the working posture assessment system such as OWAS, RULA and REBA were used to evaluate the appropriacy of working weight and posture by manual transfer of projectile. The configuration and operation procedure of projectile transfer systems which were developed to improve work efficacy and to reduce the burden of manual transferring were described. The improvements were assessed by the number of processes, the tact time and the working posture assessment for operation of this system by comparing to the manual transfer of projectile.

Wireless Power Transfer System Insensitive to Pickup's Posture (Pickup의 자세에 둔감한 무선전력전송 시스템)

  • Lee, Dong-Su;Lim, Dong-Nam;Jeon, Seong-Jeub
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.910-915
    • /
    • 2014
  • Recently, wireless power transfer (WPT) system is widely studied. WPT system is very attractive because it removes power cables from home appliances, office equipment and battery chargers for electric vehicle. However, pickup's posture affects the performance greatly. In this paper a new pickup system whose output voltage is less sensitive to its posture is proposed. The proposed pickup system is composed of three coils perpendicular to each other. A prototype is constructed and tested, and its usefulness is verified.

A study on the human impulse characteristics with the typical shooting posture (주요 사격자세에 따른 인체 충격량 특성 해석)

  • Choi, Young-Jin;Lee, Young-Shin;Han, Kyoo-Hyun;Chae, Je-Uk;Choi, Eui-Jung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.459-464
    • /
    • 2004
  • The rifle impact of human body affected by the posture of human for rifling. The interaction human-rifle system influence the firing accuracy. In this paper, impact analysis of human model for shooting posture is carried out. ADAMS code and LifeMOD is used in impact analysis of human model and modeling of the human body, respectively. On the shooting, human model is affected by rifle impact during the 0.001 second. Performed simulation time for shooting is 0.1 second. Applied constraint condition to human-rifle system is rotating and spherical condition. As the results, the displacement of rifle and transfer path analysis of impact of human model is presented.

  • PDF

Tactile Transfer and Display Method using Data Glove and Vibration Motors Module (데이터 글로브와 진동모터를 이용한 촉각전달 및 제시 방법)

  • Kang, Hyung-Gu;Choi, Youngjin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1138-1144
    • /
    • 2013
  • This paper proposes a tactile transfer and display method between a data glove and vibration motors module. The data glove is developed to capture the hand postures and to measure the grip forces. The measured data are simplified with the proposed 5-bit transfer and display algorithm, and the vibration motors module is developed to display the measured hand posture and grip force to the operator. The proposed 5-bit algorithm contains both an 8-step hand posture and 4-step grip force level information for tactile transfer to the vibration motors module. Also, the effectiveness of the proposed method is shown through several experiments.

Goal-Posture-Determination of a Steerable Mobile Robot for Active Information Display

  • Lee, Jeong-eom;Yi, Chong-ho;Kim, Dong-won
    • Journal of Platform Technology
    • /
    • v.6 no.4
    • /
    • pp.3-10
    • /
    • 2018
  • A projection-based active information display system was proposed. The proposed system is based on Intelligent Space and a steerable projector mounted mobile robot which is called Ubiquitous Display (UD). In order to transfer visual information for a human in the Intelligent Space, the UD projects a certain shape of an image with a fixed size. Due to redundancy of degree of freedom (DOF), there are lots of situations to project a same shape and size of the image on a surface. In this paper, we describe a method to determine a goal posture of the UD. Here, the goal posture is the most efficient position and orientation of the UD so as to project visual information and it is determined by the Intelligent Space. To verify the proposed method, simulation and demonstration are carried out.

Development of Textile Sensors for Prevention of Forward Head Posture (거북목 예방을 위한 텍스타일 센서 개발)

  • Minsuk kim;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.4
    • /
    • pp.125-140
    • /
    • 2023
  • This study aimed to develop a smart wearable device for assessing the risk angle associated with turtle neck syndrome in patients with Video Display Terminal (VDT) syndrome. Turtle neck syndrome, characterized by forward head posture resulting from upper cross syndrome, leads to thoracic kyphosis. In this research, a stretch sensor was used to monitor the progression of turtle neck syndrome, and the sensor data was analyzed using a Universal Testing Machine (UTM) and the Gauge Factor (GF) calculation method. The scapula and cervical spine angles were measured at five stages, with 15-degree increments from 0° to 60°. During the experimental process, the stretch sensor was attached to the thoracic spine in three different lengths: 30mm, 50mm, and 100mm. Among these, the attachment method yielding the most reliable data was determined by measuring with three techniques (General Trim Adhesive, PU film, and Heat Transfer Machine), and clothing using the heat transfer machine was selected. The experimental results confirmed that the most significant change in thoracic kyphosis occurred at approximately 30° of forward head posture. Prolonged deformity can lead to various issues, highlighting the need for textile sensor solutions. The developed wearable device aims to provide users with real-time feedback on their turtle neck posture and incorporate features that can help prevent or improve the condition.

Comparison of Endotracheal Intubation to Transfer - A Study of Simulation Using the SALT - (이송 중 기관내 삽관의 효율성 비교 - SALT를 이용한 시뮬레이션 연구 -)

  • Yun, Seong-Woo;Jung, Jun-Ho;Lee, Hyo-Ju;Choi, Mi-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.300-302
    • /
    • 2022
  • The purpose of this study is to compare the speed, confidence, and ease of endotracheal intubation in a transfer posture by using the SALT(Supraglottic Airway Laryngopharyngeal Tube), and a direct laryngoscope to improve the ability to implement professional airway management. The subject of the study was an experimental study by a randomized crossover design, targeting 28 first-class emergency medical technicians working in J-do fire station, and the SPSS 20.0 version was used for data analysis. The endotracheal intubation by using SALT showed a significant difference in speed compared to endotracheal intubation by using a direct laryngoscope(p<.001), and also showed a significant difference in confidence and ease(p<.001). If it is transfer to endotracheal intubation by direct laryngoscope, or in the case of transfer patients, if SALT is used, safe and rapid intubation will be possible.

  • PDF

Wireless Power Transfer System using Semi-random Magnetic Field (semi-random 자장을 사용하는 적합한 무선전력전송 시스템)

  • Lim, Dong-Nam;Lee, Dong-Su;Jeon, Seong-Jeub
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.480-481
    • /
    • 2014
  • In this paper, a feeder system for wireless power transfer is investigated, which generates semi-random magnetic field using three currents with different frequencies. A semi-random field is very useful to magnetizing a pickup irrespective of its posture.

  • PDF

Wireless Power Transfer System Based on Semi-random Magnetic Flux (준랜덤 자속을 사용하는 무선전력 전송 시스템)

  • Heo, Joon;Jeon, Seong-Jeub
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1222-1229
    • /
    • 2017
  • In this paper, a wireless power transfer system with semi-random magnetic flux is studied. Directions of semi-random magnetic flux are changing almost randomly which can induce voltages at coils irrelevantly to coil's posture. So, very convenient charging is possible. Semi-random magnetic flux can be generated by a coil system which has three coils perpendicular to each other and carrying currents with different frequencies. A prototype for charging mobile devices is constructed and tested, and the proposal is verified.