• Title/Summary/Keyword: Transfer device

Search Result 1,122, Processing Time 0.029 seconds

Structural Analysis of a Carriage Shuttle System : A Material Supply Device for Small-Scale Machine Tools (소규모 공작기계용 소재공급장치의 이송 셔틀 시스템에 관한 구조해석)

  • Kang, Dae-Sung;Jung, Eun Ik;Kim, Kyung-Heui;Baek, Il-Cheon;Yi, Chung-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.62-68
    • /
    • 2019
  • The aim of this study was to interpret the structure and dynamics of a transfer shuttle system as a material supply device for small machine tools. The following conclusions were obtained by performing a structural interpretation of the material supply equipment with respect to workload and the dynamical interpretation of a flexible multibody carriage shuttle. When a 1,000-kg workload was applied to a fork lift, the safety factor was approximately 1.86. To conservatively assess the integrity of the structure, a 1,000-kg workload would be proper. In the case of a deflection of the fork system, the width increased with increasing time. The greatest deflection occurred at 5.5 s, which was the largest increase in the time point of the fork system.

Development of microfluidic green algae cell counter based on deep learning (딥러닝 기반 녹조 세포 계수 미세 유체 기기 개발)

  • Cho, Seongsu;Shin, Seonghun;Sim, Jaemin;Lee, Jinkee
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • River and stream are the important water supply source in our lives. Eutrophication causes excessive green algae growth including microcystis, which makes harmful to ecosystem and human health. Therefore, the water purification process to remove green algae is essential. In Korea, green algae alarm system exists depending on the concentration of green algae cells in river or stream. To maintain the growth amount under control, green algae monitoring system is being used. However, the unmanned, small and automatic monitoring system would be preferable. In this study, we developed the 3D printed device to measure the concentration of green algae cell using microfluidic droplet generator and deep learning. Deep learning network was trained by using transfer learning through pre-trained deep learning network. This newly developed microfluidic cell counter has sufficient accuracy to be possibly applicable to green algae alarm system.

Design and Implementation of Magnetic Stimulation Device Suitable for Herpes Zoster and Post Herpetic Neuralgia

  • Tack, Han-Ho;Kim, Gye-Sook;Kim, Whi-Young
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.199-214
    • /
    • 2020
  • An important technique of the present invention is primarily to parallel light detection, self-pulse therapy after diagnosis. Herpes zoster is a disease caused by varicella zoster virus, and the virus that has been latent in the dorsal root ganglion that controls the skin segment loses its immune system and physically damages it. It is an acute skin disease in which acute pain and bullous rash occur along the sensory ganglia, which are rehab by inducers such as malignant tumors. Dorsal root ganglion after complete recovery of varicella, relapsed after incubation in brain ganglion, latent virus sometimes suppressed activity by cell mediated immunity, and in cell ganglion with reduced cellular immunity. It proliferates and destroys neurons, causing pain while forming a rash and blisters. This can reduce cell necrosis and increase the phagocytosis and enzymatic activity through the movement of ions through the cell membrane, depolarization and membrane potential change, growth factor secretion, calcium ion transfer, chondrocyte synthesis, etc., And may offer treatment options for lesions of herpes zoster and post-herpetic neuralgia (PHN).Therefore, according to the present research, the diagnosis and treatment device of treating paing for herpes zoster and post-herpetic pain can be implemented in the early stage of herpes zoster, and conventional analgesic regulation, anti-inflammatory effect, post-herpetic neuralgia.

In situ Gelation of Monodisperse Alginate Hydrogel in Microfluidic Channel Based on Mass Transfer of Calcium Ions (미세 채널에서 칼슘이온 물질전달을 이용한 단분산성 알지네이트 하이드로젤 입자의 실시간 젤화)

  • Song, YoungShin;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.632-637
    • /
    • 2014
  • A microfluidic method for the in situ production of monodispersed alginate hydrogels using biocompatible polymer gelation by crosslinker mass transfer is described. Gelation of the hydrogel was achieved in situ by the dispersed calcium ion in the microfluidic device. The capillary number (Ca) and the flow rate of the disperse phase which are important operating parameters mainly influenced the formation of three distinctive flow regions, such as dripping, jetting, and unstable dripping. Under the formation of dripping region, monodispersed alginate hydrogels having a narrow size distribution (C.V=2.71%) were produced in the microfluidic device and the size of the hydrogels, ranging from 30 to $60{\mu}m$, could be easily controlled by varying the flow rate, viscosity, and interfacial tension. This simple microfluidic method for the production of monodisperse alginate hydrogels shows strong potential for use in delivery systems of foods, cosmetics, inks, and drugs, and spherical alginate hydrogels which have biocompatibility will be applied to cell transplantation.

Endothermic Forster Energy Transfer from DPVBi to BCzVBi in High Efficient Blue Organic Light-Emitting Diodes (고효율 청색 유기발광다이오드의 DPVBi와 BCzVBi 사이에서 발생하는 흡열 페르스터 에너지전이)

  • Kim, You-Hyun;Lee, Sang-Youn;Song, Wook;Shin, Sung-Sik;Ryu, Dae-Hyun;Wood, Richard;Yatulis, Jay;Kim, Woo-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.291-294
    • /
    • 2010
  • In this study, we demonstrated high-efficiency blue organic light-emitting diodes (OLEDs) employing BCzVBi as a blue fluorescent dye doped into blue host material, DPVBi with various concentration. The optimized blue OLED device having high-efficiency was constructed with structure of NPB (500 ${\AA}$) / DPVBi:BCzVBi-6% (150 ${\AA}$)/$Alq_3$(300 ${\AA}$) / Liq (20 ${\AA}$) / Al (1000 ${\AA}$). The maximum luminescence of blue OLED was 13200 cd/$m^2$ at 13.8 V and current density and maximum efficiency were 26.4 mA/$cm^2$ at 1000 cd/$m^2$ and 4.24 cd/A at 3.9 V, respectively. Luminous efficiency shows two times higher than comparing with non-doped BCzVBi blue OLED whereas $CIE_{x,y}$ coordinate was similar with bare DPVBi blue OLED such as (0.16, 0.19). Electroluminescence of BCzVBi-6% doped blue OLED has two major peaks at 445 nm and 470 nm whereas pure DPVBi's blue peak appears at 456 nm and it is happened through endothermic Forster energy transfer by molecule's vibration between LUMO of DPVBi as host material and LUMO of BCzVBi as dopant in device.

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

Study on Optical Characteristics of Organic Light-emitting Diodes Using Two Fluorescence Dopants in Single Emissive Layer (2개의 형광 도판트를 적용한 단일발광층 유기발광소자의 광학적 특성 연구)

  • Kim, Tae-Gu;Oh, Hwan-Sool;Kim, You-Hyun;Kim, Woo-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.184-189
    • /
    • 2010
  • Organic light-emitting diodes (OLEDs) with single emissive layer structures using two fluorescent dopants were fabricated and the device was composed of ITO / NPB ($700{\AA}$) / MADN : C545T - 1.0% : DCJTB - 0.3% ($300{\AA}$) / Bphen ($300{\AA}$) / LiF ($10{\AA}$) /Al ($1,000{\AA}$). C545T and DCJTB were functioned as green fluorescent dye and red fluorescent dye under MADN as host material. Concentrations of C545T and DCJTB was changed in emissive layer of MADN. Optimized OLED device using two fluorescence dopants shows emission efficiency of 8.42 cd/A and luminescence of 3169 cd/$m^2$at 6 V with CIE color coordinate, (0.43, 0.50). Electroluminescence of optimized OLED showed two peak at 500 and 564 nm according to C545T and DCJTB. These results indicate that F$\ddot{o}$ster energy transfer energy transfer was from MADN to C545T and rather than to DCJTB continuously.

Design and Performance Analysis of Magnetic Resonant Wireless Power Transfer Receiver for Implant Medical Device (인체 삽입형 자기 공진 무선전력전송 수신기 설계 및 성능 분석)

  • Kim, Sungjae;Ku, Hyunchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.935-941
    • /
    • 2018
  • In this study, we propose a suitable magnetic resonant wireless power transfer(WPT) system topology for size-limited implant medical devices(IMDs). The proposed modified series-parallel topology(mSPT) can be implemented by adding an inductor in series to the parallel-connected Rx coil and a capacitor. The topology achieves high efficiency when the Rx coil has a small inductance. The validity and operating conditions of the system are verified theoretically through circuit analysis. Experiments were conducted with bio-blocks, which are made of pork fat and muscle. When the Rx coils were inserted into the blocks at a depth of 2.5~10 mm, mSPT showed 17.79 % improved efficiency on average compared with the conventional series-series topology(SST). In the case of 32 dBm WPT in air, the Rx coil's heating rate for the mSPT was $0.18^{\circ}C/s$, whereas the SST was $0.75^{\circ}C/s$. It was confirmed that the mSPT is more suitable for an IMD-targeted WPT system.

A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System (심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구)

  • Lee, Jung-Hee;Lee, Young-Shin;Lee, Yong-Ho;Lim, Hyun-Kyoon;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • A magnetocardiogram (MCG) is a recording of the biomagnetic signals generated by cardiac electrical activity. Biomagnetic instruments are based on superconducting quantum interference devices (SQUIDs). A liquid cryogenic Dewar flask was used to maintain the superconductors in a superconducting state at a very low temperature (4 K). In this study, the temperature distribution characteristics of the liquid helium in the Dewar flask was investigated. The Dewar flask used in this study has a 30 L liquid helium capacity with a hold time of 5 d. The Dewar flask has two thermal shields rated at 150 and 40 K. The temperatures measured at the end of the thermal shield and calculated from the computer model were compared. This study attempted to minimize the heat transfer rate of the cryogenic Dewar flask using an optimization method about the geometric variable to find the characteristics for the design geometric variables in terms of the stress distribution of the Dewar flask. For thermal and optimization analysis of the structure, the finite element method code ANSYS 10 was used. The computer model used for the cryogenic Dewar flask was useful to predict the temperature distribution for the area less affected by the thermal radiation.