• 제목/요약/키워드: Transfer device

검색결과 1,122건 처리시간 0.028초

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • 대한물리치료과학회지
    • /
    • 제29권1호
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

연료전지 냉각용 헬리컬 인서트디바이스 이중관열교환기의 열전달 성능 향상에 관한 연구 (A Study on the Improvement of Efficiency of Heat Transfer of Double Pipe Heat Exchanger with Helical Insert Device on Cooling of a Fuel Cell)

  • 조동현
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1872-1879
    • /
    • 2015
  • The present study was conducted on the improvement of the heat transfer performance of double pipe heat exchangers with helical insert device. Double pipe heat exchangers with helical insert device were studied for improvement of the heat transfer performance of double pipe heat exchangers with helical insert device and plain double pipe heat exchangers were also studied to comparatively analyze heat transfer performance. Experimental results were derived on changes in the Reynold's numbers of the cooling water flowing in helical and plain double pipe heat exchangers and changes in the heat flux of the air. Thereafter, to verify the reliability of the experimental results, the theoretical total energy and the experimental total energy were comparatively analyzed and the following results were derived. The thermal energy of the calorie lost by the hot air and that of the calorie obtained by the cooling water were well balanced. The experiments of plain double pipe heat exchangers and double pipe heat exchangers with helical insert device were conducted under normal conditions and the theoretical overall heat transfer coefficient value and the experimental overall heat transfer coefficient value coincided well with each other. In both plain double pipe heat exchangers and double pipe heat exchangers with helical insert device, heat transfer rates increased as the cooling water flow velocity increased. Under the same experimental conditions, the heat transfer performance of double pipe heat exchangers with helical insert device was shown to be higher by approximately 1.5 times than that of plain double pipe heat exchangers.

가진입력에 의한 손떨림 보정용 이송장치의 둔화현상 방지대책 (A Method to Prevent Transfer Device of Image Stabilizer from Blunting by Artificial Vibration)

  • 염동회
    • 제어로봇시스템학회논문지
    • /
    • 제15권11호
    • /
    • pp.1076-1079
    • /
    • 2009
  • This article deals with an optical image stabilizer which moves an image sensor in the direction of cancelling the vibration caused by hand shaking to prevent a photographed image from blurring. The ball-guide way method adopted as a transfer device of the image sensor is easy to be manufactured because of its simple structure and is suitable to minimize the friction between mechanisms, but has weakness of a chance of physical defect such as groove and rising. In case that the movement of the transfer device equipped with the image sensor is blunted because a ball is stuck in defects of guide way, the performance of the image stabilizer falls down drastically. We propose a method to prevent the transfer device from blunting by applying artificial vibration. At this time, the artificial vibration should be designed under consideration of dynamic characteristics and specifications of the system to be discriminated from the vibration caused by hand shaking.

프레스 공정 단축을 위한 회전식 트랜스퍼 성형장치 개발 (Development of Rotary Transfer Forming Device for Process Reduction in Forming)

  • 김승기;윤재웅
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.413-420
    • /
    • 2014
  • Although the transfer forming process has various advantages, it is also inefficient for the use of multiple press machines, especially for small part sizes. In this study, a new forming process was proposed to use multiple tandem dies in a single press machine. A rotary transfer forming device was developed to combine the advantages of the progressive and transfer forming process. In this study, a detailed forming process using this device was analyzed, and the device was designed to perform four series of tandem forming processes in a single press. In order to analyze the feasibility of this forming process, simple forming dies were made. As a result, the position accuracy was 4 arcsec, and the forming speed reached up to 20 strokes per minute. It is thought that this rotary transfer forming device can help to save initial setup costs through the more efficient use of space in a press machine.

Development and usability test of transfer device with customized sling lifts

  • SeYeon Jeong;KiHun Cho;SoungKyun Hong;WonJae Choi;Kwangkook Lee;Kyeongbong Lee;GyuChang Lee
    • 대한물리치료과학회지
    • /
    • 제30권4호
    • /
    • pp.9-16
    • /
    • 2023
  • Background: Bedridden patients and disabled persons need help from a guardian or caregiver even in performing simple activities of daily living. In particular, for body transfer of them, the use of a transfer lift has been recommended. However, the devices currently in use have limitations in terms of support according to the individual's characteristics. This study aimed to develop a transfer lift device utilizing the patients' body-fitting sling equipped with an air tube inside the sling. In addition, we have conducted usability tests to examine the safety, effectiveness, and satisfaction with this device. Design: This study conducted usability tests with 10 healthy adults. Methods: Customized sling lifts are generally floor-based devices that consisted of a sling that holds the patient's body and a lift that moves the sling to the desired position. One characteristic feature of the device is an air tube, which is used on the sling to allow the patient's body can be adjusted. A usability test was performed in terms of the operators, who operated the device to transfer the patients. Ten operators tried the device and tested its usability. Results: The mean of 10 question for Questions was 4.18. Conclusion: The device can be useful in the advance- ment and commercialization of customized sling lifts, to ensure the safe and efficient transfer of persons with disabilities.

Circuit Properties and Device Characteristics of Printed Circuit Board Windings Employed as Contactless Energy Transfer Device

  • Nho Jaehyun;Lim Wonseok;Choi Byungcho;Ahn Taeyoung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.11-16
    • /
    • 2001
  • Recent publications showed that a pair of neighboring printed circuit board (PCB) windings can be used as a contactless energy transfer device. As a continued study on this area, the current paper presents the modeling, analysis, and application of the neighboring PCB windings with an emphasis on their circuit properties and device characteristics as a contactless energy transfer device. Theoretical results of the paper are confirmed with experiments on a prototype contactless energy transfer circuit that delivers 24W output power at $68\%$ efficiency through two 35mm-diameter PCB windings separated each other by 2.4mm.

  • PDF

혈관 내 폐 보조장치에서의 산소전달속도 예측에 관한 연구 (A Study of Prediction of Gas Transfer rate in Intravascular Lung Assist Device)

  • 김기범;나도춘;김성종;정인수;정경락;권대규
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.18-25
    • /
    • 2004
  • 본 연구의 목적은 정맥 내 폐 보조장치 설계에 있어서 기체전달을 예측하기 위하여 혈관 내 폐 보조장치를 정맥 내에 삽입하기 전, 여러 가지 설계조건에서 실험적 모델링을 통하여 예측식을 찾고자 시도하였다. 실험결과 중공사 충진율의 함수에 따라 기체전달을 예측할 수 있었다. 실험에 의하여 얻어진 기체전달은 예측식에 의한 기체전달과 유사하여, 식에 대한 신뢰성을 얻을 수 있었다. 그러므로, 중공사의 충진율의 함수에 따라 기체전달을 예측할 수 있으며, 혈관 내 폐 보조장치의 기체전달을 예측하는데 매우 유용하였다.

Application of a foil transfer for CRT Screen processing

  • Ryu, Sang-Chul;Kim, Sang-Mun;Lee, Koo-Hwa;Keun, Yoon-Kyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.864-867
    • /
    • 2002
  • LG Electronics developed a perfect flat color display tube which was named "FLATRON" . This tube provides ergonomic performances with perfectly flat face and innovative manufacturing process. Foil transfer is a new technology for manufacturing screen layer for Flatron. Its main features include several properties of film, releasing agent, adhesive, aluminum layer, holes after bake-out and foil transfer process. It will be used innovative and cost oriented process for FLATRON for in CRT mass production..

  • PDF

전력변환차단기의 트리거 기구 최적화 (Optimization ova Mechanism for Power Transfer Breakers)

  • 조두현;김권희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.735-739
    • /
    • 2002
  • PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.

  • PDF

식물공장용 포트묘 로봇 이식기 개발 (Development of a Robotic Transplanter for Pot-Seedlings of Plant Factory)

  • 류관희;김기영;류영선;한재성;신태웅
    • Journal of Biosystems Engineering
    • /
    • 제23권3호
    • /
    • pp.277-284
    • /
    • 1998
  • This study was conducted to develop m automatic pot-seedling transplanter for plant factory. The transplanter consists of a gripper, row-spacing control device, nursing tray transfer system, growing trough transfer system, and gripper moving device. The gripper picks up pot-seedling. The gripper moving device moves the gripper between nursing tray and growing-flat. Nursing trays are moved to workspace by the nursing tray transfer system. The growing trough transfer system was developed to move growing trough to workspace. The row-spacing control device was used to adjust the distance between adjacent plants traversely. The results of this study are as follows. The transplanting capacity of the developed transplanter was 7.1 seconds per cycle or 1.18 second per pot-seedling. Successful planting was 98.9% without seedlings and 95.8% with seedlings.

  • PDF