• Title/Summary/Keyword: Transfer Path Analysis

Search Result 247, Processing Time 0.027 seconds

Prediction of Powertrain Structure-borne Noise Using Hybrid Model (하이브리드 모델을 이용한 파워트레인 가진에 의한 구조 기인 소음 예측)

  • Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.12-22
    • /
    • 2007
  • This paper presents to predict the powertrain structure-borne noise which is primary resource of interior noise. As the first step, it is built up a hybrid powertrain model which is based on the real powertrain which is verified with static and dynamic properties. The methods for verifying are modal analysis and running vibration testing which are experimentally implemented. Based on the Hybrid powertrain component model, an initial predictive assembly model is simulated. As the second step, the characteristic transfer functions are measured that are dynamic stiffness of rubber mounts and vibro-acoustic transfer function based on the acoustic reciprocity. Several techniques utilizing special experimental devices have been proposed for this research. Finally, the structure-borne noise by powertrain will be predict and verify with dynamic simulation and experiment.

  • PDF

Experimental Study and Evaluation Method for Sloshing Noise of Fuel Tank on Passenger Vehicle (승용차량용 연료탱크 슬로싱 현상에 대한 실험적 고찰 및 평가 방법에 대한 연구)

  • Ahn, Sejin;Yoon, Seongho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.444-451
    • /
    • 2014
  • The signal patterns of slosh noise produced by the fuel tank of a passenger vehicle are characterized by analyzing vehicle interior noise, fuel tank vibration, and near-field noise radiated from the fuel tank. This paper also shows the noise transfer path analysis results performed from the fuel tank to the vehicle inside. On top of them, physical index is described, demonstrating a good correlation with subjective feeling of slosh noise. It is essential to identify the main noise transfer paths for redesigning of the fuel tank system aiming at reducing slosh noise and also helpful to apply physical index in evaluating and reducing this noise. It is found that structure-borne path is the main root of slosh noise and a value reveals a good correlation with subjective feeling.

Re-evaluation of Force Transfer Mechanism of Reduced Beam Section (Dogbone) Seismic Steel Moment Connections (보 플랜지 절취형 (독본) 내진 철골모멘트 접합부의 응력전달 메카니즘 재평가)

  • 이철호;김재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.221-230
    • /
    • 2003
  • Employing classical beam theory for the design of RBS seismic steel moment connections was brought into question in this study, Both the experimental strain data and analytical results from the calibrated finite element analysis confirmed that the shear transfer mechanism in the RBS connection is completely different from that as predicted by classical beam theory Plausible explanations of a higher incidence of brittle fractures observed in the specimens with bolted-webs were presented. It was pointed out that the practice of providing web bolts uniformly along the beam depth is not consistent with the load path identified by both experimental and analytical results. More rational bolted-web details were proposed based on the identified principal load path,.

  • PDF

Analysis on the Thermal Performance of an Ammonia Unit Cooler (암모니아 유니트 쿨러의 열성능 해석)

  • 최재광;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

A Study on Selected Station Analysis of AFC-Based Integrated Transit Network - Focused on Subway Transfer Stations in Seoul Metropolitan Area - (AFC-기반 통합대중교통 네트워크의 Selected Station Analysis (SSA) 연구 - 수도권 지하철 환승역사를 중심으로 -)

  • Lee, Mee Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.6
    • /
    • pp.67-83
    • /
    • 2018
  • This research is motivated by the question, "Where, when, and through what mode does an individual passenger moving within a subway station use to travel from starting to final destinations ?" To answer this, the stations passed by the individual passenger, the path taken, and modes used need to be known beforehand. In the metropolitan integrated public transportation fare system, Automated Fare Collection System(AFC) can be a source of information on transit modes, stations, and paths of individual passengers. AFC calculates a fare for the passenger based on travel data such as boarding and alighting stations, time, and mode used. In this research, an Selected Station Analysis(SSA) method, in which AFC data is used to observe passenger movement in the metropolitan public transportation subway station from the perspective of subway transfer stations, is proposed. SSA subdivides individual passenger movement in transfer stations and analyzes initial station/time and final destination station/time information using the trip chain perspective.