• Title/Summary/Keyword: Transfer Operation

Search Result 1,530, Processing Time 0.033 seconds

Study on the Structure Optimization and the Operation Scheme Design of a Double-Tube Once-Through Steam Generator

  • Wei, Xinyu;Wu, Shifa;Wang, Pengfei;Zhao, Fuyu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.1022-1035
    • /
    • 2016
  • A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure.

A Comparative Study on Early Algebra between Korea and USA Textbooks -focusing to operation sense in the elementary mathematics- (우리나라와 미국의 초기대수 비교 연구 -초등수학 교과서에 제시된 연산 감각을 중심으로-)

  • Kim, Sung Joon
    • East Asian mathematical journal
    • /
    • v.29 no.4
    • /
    • pp.355-392
    • /
    • 2013
  • Generally school algebra is to start with introducing variables and algebraic expressions, which have major cognitive obstacles to students in the transfer from arithmetic to algebra. But the recent studies in the teaching school algebra argue the algebraic thinking from an early algebraic point of view. We compare the Korean elementary mathematics textbooks with Americans from this perspective. First, we discuss the history of school algebra in the school curriculum. And Second, we investigate the recent studies in relation to early algebra. We clarify the goals of this study(the importance of early algebra in the elementary school) through these discussions. Next we examine closely the number sense in the arithmetic and the symbol sense in the algebra. And we conclude that the operation sense can connect these senses within early algebra using the algebraic thinking. Finally, we compare the elementary mathematics books between Korean and American according to the components of the operation sense. In this comparative study, we identify a possibility of teaching algebraic thinking in the elementary mathematics and early algebra can be introduced to the elementary mathematics textbooks from aspects of the operation sense.

Arterial Switch Operation: The Technical Modification of Coronary Reimplantation and Risk Factors for Operative Death (동맥전환술: 판상돔맥이식 수기변형과 수술사망의 위험인자)

  • 성시찬;이형두;김시호;조광조;우종수;이영석
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.235-244
    • /
    • 2004
  • Anatomic correction of the transposition of the great arteries (TGA) or Taussig-Bing anomaly by means of the arterial switch operation is now accepted as the therapeutic method of choice. This retrospective study was conducted to evaluate the risk factors for operative deaths and the efficacy of technical modification of the coronary transfer. 85 arterial switch operations for TGA or Taussig-Bing anomaly which were performed by one surgeon from 1994 to July 2002 at Dong-A university hospital were included in this retrospective study Multivariate analysis of perioperative variables for operative mortality including technical modification of the coronary transfer was peformed. Overall postoperative hospital mortality was 20.0% (17/85). The mortality before 1998 was 31.0% (13/42), but reduced to 9.3% (4/43) from 1998. The mortality in the patients with arch anomaly was 61.5% (8/13), but 12.5% (9/72) in those without arch anomaly. In patients who underwent an open coronary reimplantation technique, the operative mortality was 28.1% (18/64), but 4.8% (1/21) in patients undergoing a technique of reimplantation coronary buttons after neoarotic reconstruction. Risk factors for operative death from multivariated analysis were cardiopulmonary bypass time ($\geq$ 250 minutes), aortic cross-clamping time ($\geq$ 150 minutes), aortic arch anomaly, preoperative event, and open coronary reimplantation technique. Operative mortality has been reduced with time. Aortic arch anomaly and preoperative events were important risk factors for postoperative mortality. However atypical coronary artery patterns did not work as risk factors. We think that the technical modification of coronary artery transfer played an important role in reducing the postoperative mortality of arterial switch operation.

ANALYSIS OF HEAT TRANSFER ON SPENT FUEL DRY CASK DURING SHORT-TERM OPERATIONS (사용후핵연료 건식 용기의 단기운영공정 열전달 평가)

  • Kim, H.;Lee, D.G.;Kang, G.U.;Cho, C.H.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • When spent fuel assemblies from the reactor of nuclear power plants(NPPs) are transported, the assemblies are exposed to short-term operations that can affect the peak cladding temperature of spent fuel assemblies. Therefore, it needs to perform the analysis of heat transfer on spent fuel dry cask during the operation. For 3 dimensional computational fluid dynamnics(CFD) simulation, it is proposed that the short-term operation is divided into three processes: Wet, dry, and vacuum drying condition. The three processes have different heat transfer mode and medium. Metal transportation cask, which is Korea Radioactive Waste Agency(KORAD)'s developing cask, is evaluated by the methods proposed in this work. During working hours, the boiling at wet process does not occur in the cask and the peak cladding temperatures of all processes remain below $400^{\circ}C$. The maximum peak cladding temperature is $173.8^{\circ}C$ at vacuum drying process and the temperature rise of dry, and vacuum drying process occurs steeply.

Reconstruction of the Shoulder using Rotational Latissimus Dorsi Flap in the Malignant Fibrous Histiocytoma (악성 섬유성 조직구종에서 광배근피판을 이용한 견관절 재건술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Young-Ho;Im, Yang-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • Introduction : The Functional muscle transfer is used to reconstruct the injuried muscle and paralysis of the shoulder. Especially transfer of the trapezius has been the treatment of choice but it has disadvantages of inadequate function and deformed contour, and instability of humeral head in case of acromion resection. We report an operation for shoulder reconstruction after wide resection of malignant fibrous histiocytoma, using rotational latissimus dorsi flap and review the operation method and clinical outcome. Materials and Methods : A patient, 53 year old, with malignant fibrous histiocytoma in the acromioclavicular joint area had been underwent wide excision, including the deltoid, clavicular head of pectoralis major, part of trapezius, lateral 1/3 of clavicle and acromion including scapular spine. The rotational latissimus dorsi flap with its neurovascular pedicle was dissected and then placed over the resected area and transfer of muscle attached at coracoid process was done to achieve stability of the humeral head. The range of motion of the shoulder and test of muscle power were evaluated for functional outcome. Total follow-up period is 2 years 11 months. Results : At last follow-up, the range of motion of the shoulder is abduction $90^{\circ}$, flexion $90^{\circ}$, internal rotation $40^{\circ}$, external rotation $50^{\circ}$ and the muscle power is 4 grade in all direction and then we obtained good functional results. There are no complications such as instability or subluxation of the humeral head and deformed contour and he is a disease-free survival state. Conclusions : The transfered latissimus dorsi flap provides adequate lever arm and stabilization and covering of the humeral head by sufficient muscle volume and width. This procedure can be useful not only for the paralysed deltoid reconstruction but also for use in reconstructive surgery after wide resection of the shoulder for malignant tumor.

  • PDF

Toe to Finger Transfer in Traumatic Amputated Index Finger (외상성 시지 결손 환자에서 족지를 이용한 수지 재건술)

  • Lee, Kwang-Suk;Park, Sang-Won;Kang, Oh-Yong;Choi, Yong-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1993
  • Traumatic loss of the fingers present significant functional disability and the index finger is an important component of hand function. Since 1900, many attempts and efforts have been done in reconstruction of amputated fingers with toes. Authors clinically analyzed 8 cases of toe-to-finger transfer in traumatic amputation of the index finger to be followed for more than one year at Korea University Hospital from August 1982 to December 1991. The results were as follows: 1. The most common cause of injury was mechanical accident in 7 of 8 cases. 2. Average interval between injury and operation was 8 year 3 months. 3. Average operation time was 5 hours 58 minutes and average ischemic time of transferred toe was 1 hour 52 minutes. 4. Skin flaps have survived in 7 of 8 cases, and the functional results in 6 of 8 cases were over than fair.

  • PDF

The Operation of the Yard in a Terminal (터미널의 장치장 운영)

  • Ahn, Eun Yeong;Kang, Byoungho;Kang, Jaeho;Ryu, Kwang Ryel;Kim, Kap Hwan
    • Journal of Intelligence and Information Systems
    • /
    • v.12 no.3
    • /
    • pp.47-65
    • /
    • 2006
  • These days, the number of automated container terminals is increasing to encourage the productivity of the container terminal inside and outside of the country. So far, there have been a lot of researches on the operating one type of equipments in a container terminal. However, there is still room for further improvement as none of equipment works itself but cooperate each other to finish a job, which means synchronization among the equipments is necessary. Among lots of equipments in a terminal, this paper concerns with the operation of ATCs (Automated Transfer Crane) and YTs (Yard Truck). The purpose of this paper is to find the efficient heuristic methods for operating ATCs and YTs that can set up a schedule in a real time. Moreover, using simulation this paper shows the efficient stacking strategy to decide the location of containers to be put and the proper selection range of YTs.

  • PDF

A Feasibility Study for the Application of the Cold-heat Storage System Considering the Real Operation Status of the Showcase (쇼케이스의 실제 운전상태를 고려한 축냉시스템 적용 가능성 평가 기초 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.52-58
    • /
    • 2012
  • Experimental study was performed to understand the real operation conditions of a showcase working usually in a convenient store and discount store. The purpose of this study was to show the possibility for practical use of cold-heat storage systems being operated for the showcase. To do that, evaporator and condenser temperatures were measured and the compressor electric power consumption were measured simultaneously. To use the ice storage system, the ice making process was typically operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was subcooled using the stored cold-heat after being discharged from the condenser during daytime. So, the cooling performance was increased with the sub-cooling of refrigerant during daytime,hence the actual running time of the compressor could be effectively decreased. Through the experiments, this study showed that the compressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling. So, for the convenient store, the maximum load transfer rates for each working cooler and showcase were estimated about 31.1% and 19.9% respectively. And for the discount store, the maximum load transfer rates for each refrigeration and freezing showcase were estimated about 34.1% and 49.0% respectively.

Performance Compensation of the Satellite Imager below Normal Altitude Using Line-Of-Sight Tilt over Spherical Earth Surface (구면 지표에서 경사촬영을 이용한 위성 영상기의 고도 저하 성능 보정)

  • 조영민
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2004
  • A spherical earth surface is used for realistic analysis of the geometrical performance characteristics generated by 2-dimensional line-of-sight (LOS) tilt of the satellite imager using the Time Delay and Integration(TDI) technique. A 2-dimensional LOS tilt ever the spherical Earth surface is proposed to compensate geometric performance degradation caused by the satellite altitude decrease below the normal operation altitude. The compensation can be achieved by TDI re-match without degradation of modulation transfer function and with ground sample distance slightly increased. Effective methods of LOS tilt for the compensation are investigated. This study can be useful for mission assurance and flexibility in imager operation.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.