• Title/Summary/Keyword: Transfer Floor

Search Result 204, Processing Time 0.026 seconds

Free Vibration of Vertica Pomp (대형수직펌프의 자유진동해석)

  • 배춘희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.267-272
    • /
    • 2004
  • Vertical pump are widely used owing to the fact that they occupy small floor space. In this type of pumps, however, the vibrational problems are very important, since, in many cases, they have less stiffness in comparison with later pumps. This study presents a simple solution method for calculating the natural frequencies and modes of vertical pumps. In this study, a model of a vertical pump was developed and the nondimensional parameters for the vibrational characteristics of it were determined. Added mass was calculated for the effects of water and the transfer matrix method was used.

  • PDF

Vibration Analysis of Vertical Pumps (수직펌프의 진동해석)

  • 홍진선
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.928-935
    • /
    • 1999
  • Vertical pumps are widely used owing to the fact that they occupy small floor space. In this type of pumps, however, the vibrational problems are very important, since, in many cases, they have less stiffness in comparison with lateral pumps. This study presents a simple solution method for calculating the natural frequencies and modes of vertical pumps. In this study, a mode of a vertical pump was developed and the nondimensional parameters for the vibrational characteristics of it were determined. Added mass was calculated for the effects of water and the transfer matrix method was used.

  • PDF

Development and usability test of transfer device with customized sling lifts

  • SeYeon Jeong;KiHun Cho;SoungKyun Hong;WonJae Choi;Kwangkook Lee;Kyeongbong Lee;GyuChang Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.4
    • /
    • pp.9-16
    • /
    • 2023
  • Background: Bedridden patients and disabled persons need help from a guardian or caregiver even in performing simple activities of daily living. In particular, for body transfer of them, the use of a transfer lift has been recommended. However, the devices currently in use have limitations in terms of support according to the individual's characteristics. This study aimed to develop a transfer lift device utilizing the patients' body-fitting sling equipped with an air tube inside the sling. In addition, we have conducted usability tests to examine the safety, effectiveness, and satisfaction with this device. Design: This study conducted usability tests with 10 healthy adults. Methods: Customized sling lifts are generally floor-based devices that consisted of a sling that holds the patient's body and a lift that moves the sling to the desired position. One characteristic feature of the device is an air tube, which is used on the sling to allow the patient's body can be adjusted. A usability test was performed in terms of the operators, who operated the device to transfer the patients. Ten operators tried the device and tested its usability. Results: The mean of 10 question for Questions was 4.18. Conclusion: The device can be useful in the advance- ment and commercialization of customized sling lifts, to ensure the safe and efficient transfer of persons with disabilities.

Study of the Effects of Supplier Monitoring on Shop floor Productivity (공급사 모니터링이 현장생산성에 미치는 영향에 관한 연구)

  • Cho, BooYun;Kang, Gi-Choon;Hyun, MinCheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7025-7039
    • /
    • 2014
  • Focal companies (hereafter called buyers) adopt outsourcing practices from a supply chain management strategy to be competitive. Buyers face the bridge transfer after outsourcing contracts, and the monitoring practices would be the only control mechanism left to prevent losing control over the suppliers. This study suggests the set of monitoring practices (i.e., capability, activity and outcome monitoring) as the independent variables to enhance the buyer-supplier collaboration and supplier's performance. In addition the buyer's efforts of monitoring are assumed to influence the buyer's shop floor productivity mediated by the supplier's performance and buyer-supplier collaboration. The results showed that the monitoring practices are meaningful antecedents to the supplier's performance and buyer-supplier collaboration, which fully mediates between the monitoring practices and buyer's shop floor productivity. The mediating role of the buyer-supplier collaboration between activity monitoring and shop floor productive has been rejected, because the negative effect of activity monitoring on buyer-supplier collaboration conflicts with the positive impact of buyer-supplier collaboration on shop floor productive. The theoretical contribution and managerial implications with limitations have been discussed.

A Study on the Thermal Comfort Zone and Energy Use of Radiant Floor Heating by Residential Style and Clothing Level (생활특성과 착의량에 따른 바닥복사난방 공간의 열쾌적 범위 및 에너지 사용량에 관한 연구)

  • Kim, Sang-Hun;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.24-31
    • /
    • 2015
  • The purpose of this study is to provide the thermal comfort range according to the residential style and clothing level at radiant floor heating space, and compare the annual energy consumption and energy cost for each condition. Lower neutral point temperature has been stood for floor sitting style than chair sitting style, which appears that the thermal sensation was affected by local heat transfer between floor surface and the human body. The result of research indicates that neutral point temperature was in inverse proportion with the clothing level. It is interpreted that the increasing of clothing level results decrement of heat loss from human body, and is available to achieve same thermal comfort at lower room temperature. It was analyzed that the floor sitting style is more economical residential style than the chair sitting style, because the energy consumption of the floor sitting style is saved by 6.0% in average to compare with that of the chair sitting style. It is analyzed that energy consumption has been decreased by 13.5% with the clothing level of 1.2 Clo than with that of 1.0 Clo, and decreased by 18.0% than with that of 0.8 Clo, which explains that the energy saving can be achieved with the variation in life habit to increase the clothing level.

A Study on Interior Noise Characteristics of High-speed Trains (고속철도 차량의 실내소음 특성 연구)

  • Noh, Hee-Min;Choi, Sunghoon;Kim, Seog-Won;Hong, Suk-Yoon
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • Because excessive interior noise when riding a high-speed train leads to annoyances, fatigue and stress for passengers, interior noise reduction methods should be considered. In particular, a high-speed train operated in various operation environments, and in South Korea, these include open fields and tunnels. Therefore, a specific study about changes in interior noise characteristics according to different environments is necessary. For this reason, the interior noise characteristics on a KTX train and on the KTX-Sancheon train were analyzed from noise measurements using microphones in this paper. Vibrations on the axles, bogies and floor were also measured, are these area are structural paths for interior noise. From this research, the interior noise characteristics according to the driving speed were deduced and the effects on interior noise by driving environments such as open fields and tunnels were investigated. Furthermore, the effect on interior noise by axles, bogies and floor vibrations were analyzed from a transfer function analysis.

Computerized Modules for Seismic Performance Evaluation of Existing Buildings (기존건축물 내진성능평가를 위한 전산시스템 모듈 개발)

  • Hwang, Sunwoo;Kim, Taejin;Kim, Jong-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2016
  • Seismic performance evaluation of existing building usually needs much time and man power, especially in case of nonlinear analysis. Many data interaction steps for model transfer are needed and engineers should spend much time with simple works like data entry. Those time-consuming steps could be reduced by applying computerized and automated modules. In this study, computational platform for seismic performance evaluation was made with several computerized modules. StrAuto and floor load transfer module offers a path that can transfer most linear model data to nonlinear analysis model so that engineers can avoid a lot of repetitive work for input information for the nonlinear analysis model. And the new nonlinear property generator also helps to get the nonlinear data easily by importing data from structural design program. To evaluate the effect of developed modules on each stages, seismic performance evaluation of example building was carried out and the lead time was used for the quantitative evaluation.

BEPAT: A platform for building energy assessment in energy smart homes and design optimization

  • Kamel, Ehsan;Memari, Ali M.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.321-339
    • /
    • 2017
  • Energy simulation tools can provide information on the amount of heat transfer through building envelope components, which are considered the main sources of heat loss in buildings. Therefore, it is important to improve the quality of outputs from energy simulation tools and also the process of obtaining them. In this paper, a new Building Energy Performance Assessment Tool (BEPAT) is introduced, which provides users with granular data related to heat transfer through every single wall, window, door, roof, and floor in a building and automatically saves all the related data in text files. This information can be used to identify the envelope components for thermal improvement through energy retrofit or during the design phase. The generated data can also be adopted in the design of energy smart homes, building design tools, and energy retrofit tools as a supplementary dataset. BEPAT is developed by modifying EnergyPlus source code as the energy simulation engine using C++, which only requires Input Data File (IDF) and weather file to perform the energy simulation and automatically provide detailed output. To validate the BEPAT results, a computer model is developed in Revit for use in BEPAT. Validating BEPAT's output with EnergyPlus "advanced output" shows a difference of less than 2% and thus establishing the capability of this tool to facilitate the provision of detailed output on the quantity of heat transfer through walls, fenestrations, roofs, and floors.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Design of an actuator for simulating wind-induced response of a building structure

  • Park, Eun Churn;Lee, Sang-Hyun;Min, Kyung-Won;Chung, Lan;Lee, Sung-Kyung;Cho, Seung-Ho;Yu, Eunjong;Kang, Kyung-Soo
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.85-98
    • /
    • 2008
  • In this paper, excitation systems using a linear mass shaker (LMS) and an active tuned mass damper (ATMD) are presented to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop functions are used to prevent the actuator from exciting unexpected modal responses and an initial transient response and thus, to minimize the error between the wind and actuator induced responses. The analyses results from a 76-story benchmark building problem for which the wind load obtained by a wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately reproduce the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.