• Title/Summary/Keyword: Transfer Factor Analysis

Search Result 554, Processing Time 0.032 seconds

DESIGN OPTIMIZATION OF A STAGGERED DIMPLED CHANNEL TO ENHANCE TURBULENT HEAT TRANSFER (열전달성능 향상을 위한 엇갈린 딤플 유로의 최적설계)

  • Shin, D.Y.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.159-162
    • /
    • 2007
  • This study presents a numerical procedure to optimize the shape of a staggered dimpled surface to enhance the turbulent heat transfer in a rectangular channel. A optimization technique based on neural network is used with Reynolds-averaged Navier-Stakes analysis of the fluid flow and heat transfer with Shear Stress Transport turbulence model. The dimple depth-to-dimple print diameter ratio, channel height-to-dimple print diameter ratio, and dimple print diameter-to-pitch ratio are chosen as design variables. The objective function is defined as a linear combination of terms related to heat transfer and friction loss with a weighting factor. Latin Hypercube Sampling is used to determine the training points as a mean of the Design of Experiment. Optimal values of the design variables were obtained in a range of the weighting factor.

  • PDF

Numerical Optimization of Heat Transfer Surfaces with Staggered Ribs (엇갈린 리브가 부착된 열전달면의 수치최적설계)

  • Kim, Hong-Min;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.735-740
    • /
    • 2003
  • In this study, a numerical optimization to find the optimal shape of streamwise periodic ribs mounted on both of the principal walls is performed to enhance turbulent heat transfer in a rectangular channel. The optimization is based on Navier-Stokes analysis of flow and heat transfer with $k-{\varepsilon}$ turbulence model and is implemented using response surface method. The width-to-height ratio of a rib, rib height-to-channel height ratio, rib pitch to rib height ratio and distance between opposite ribs to rib height ratio are chosen as design variables. The object function is defined as a function of heat transfer coefficient and friction drag coefficient with weighting factor. Optimum shapes of the rib have been investigated for the range of 0.0 to 0.1 of weighting factor.

  • PDF

Comparison of Safety factor for an Anchored Slope in Accordance with the Effects of Load Transfer (앵커 하중전이에 따른 사면의 안전율 비교 연구)

  • Kim, Sung-Kyu;Kim, Wak-Kyung;Park, Jong-Sik;Joo, Yong-Sun;Kim, Tae-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.55-60
    • /
    • 2008
  • This paper presents how the load transfer mechanism of the ground anchor affects on the stability analysis of anchored slope. The finite element analysis and the conventional limit equilibrium analysis on the anchored slope were performed and compared. The limit equilibrium analysis of the anchored slope is widely used in design practice due to the easiness of the analysis. However, the load transfer mechanism is not considered properly for the analysis. When the failure surface passes through the bonded length of an anchor, the anchor load is disregarded and the factor of safety for the anchored slope is smaller than it should be. In this study, the load transfer distribution was incorporated into the limit equilibrium stability analysis of the anchored slope and the results were compared with those of finite element analysis.

Analysis of Geometrical Effects on Heat Transfer Characteristics in a Modular Flat Tube-Bundle Heat Exchanger (모듈형 편평원관군 열교환기의 열전달 특성 해석)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1014-1021
    • /
    • 2005
  • Flow channels with non-circular cross-sections are encountered in a wide variety of heat exchangers. Accurate friction factor and Colburn j factor data are essential for the design and viable applications of such heat exchangers. In this study, an analysis is con ducted on heat transfer and pressure drop characteristics for tube-bundle heat exchanger with various arrangements of tubes, of which their geometry could easily be modified from a circular one in a harsh environment. The parameters investigated are aspect ratio, pitch, and inclined angle of tubes. The results obtained are: (1) Aspect ratio has larger influence on the j and f factor than pitch; (2) As aspect ratio increases, both j and f factors decrease; (3) The high performance is achieved when the pitch and aspect ratio are in the range of 1.5${\~}$2.5 and 1.25${\~}$2.0, respectively; and (4) the inclined arrangements of tubes show unfavorable results for both heat transfer and pressure drop characteristics in spite of the positive possibility of condensate removals in a latent heat recovery system.

The Influence of Self-esteem and Transfer of Learning on Organizational Commitment, in Korean Work-Learning Dual System of Engineering Students - Mediated by Self-efficacy (공학계열 일학습병행제 학생의 자아존중감과 학습전이가 조직몰입도에 미치는 영향 - 자기효능감을 매개로)

  • Kim, Changhwan
    • Journal of Engineering Education Research
    • /
    • v.27 no.1
    • /
    • pp.32-40
    • /
    • 2024
  • This study attempted to develop an efficient management plan that allows both workers and organizations to coexist by analyzing the factors that influence the level of organizational immersion of engineering students. Analysis methods included frequency analysis, t-test, pearson correlation analysis, and hierarchical analysis. Firstly, self-esteem and transfer of learning were influential factors on organizational commitment. Second, self-esteem and transfer of learning were influencing factors of self-efficacy. Third, self-efficacy was an influential factor in organizational commitment. Fourth, self-efficacy appeared as a mediating effect on self-esteem and organizational immersion in learning transfer. Therefore, it is necessary to look for various factors that can increase self-efficacy, and to find opportunities for students to be highly immersed in the organization while studying at the same time.

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

Analysis of Key Parameters for Inductively Coupled Power Transfer Systems Realized by Detuning Factor in Synchronous Generators

  • Liu, Jinfeng;Li, Kun;Jin, Ningzhi;Iu, Herbert Ho-Ching
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1087-1098
    • /
    • 2019
  • In this paper, a detuning factor (DeFac) method is proposed to design the key parameters for optimizing the transfer power and efficiency of an Inductively Coupled Power Transfer (ICPT) system with primary-secondary side compensation. Depending on the robustness of the system, the DeFac method can guarantee the stability of the transfer power and efficiency of an ICPT system within a certain range of resistive-capacitive or resistive-inductive loads. A MATLAB-Simulink model of a ICPT system was built to assess the system's main evaluation criteria, namely its maximum power ratio (PR) and efficiency, in terms of different approaches. In addition, a magnetic field simulation model was built using Ansoft to specify the leakage flux and current density. Simulation results show that both the maximum PR and efficiency of the ICPT system can reach almost 70% despite the severe detuning imposed by the DeFac method. The system also exhibited low levels of leakage flux and a high current density. Experimental results confirmed the validity and feasibility of an ICPT system using DeFac-designed parameters.

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

Male Factor Infertility and In vitro Fertilization-Embryo Transfer (남성불임증과 체외수정시술)

  • Kim, Sun-Haeng;Jung, Rae-Hwan;Ku, Pyong-Sahm
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 1992
  • In vitro fertilization and embryo transfer (IVF & ET) is widely used for the males with subnormal or abnormal semen quality, as this was recommended in view of the relatively small numbers of spermatozoa required for fertilization and subsequent pregnancies could be obtained. The aim of this study is to know how the various functional parameters of spermatozoa in semen analysis affect the outcome IVF. This study was carried out between 1988-1989, with male factor patients selected on the basis of the semen quality. The selection criteria was based upon the mean values of concentration,% motility and % normal morphology from at least two semen analysis. There is a significant decrease in the fertilization and embryo transfer rates in the study group compared with control group (35.9% vs. 68% and 48.6% vs. 85.5% respectively), however, there was no significant difference in the pregnancy or delivery rates (19.6% vs. 21.4% and 60.0% vs. 62.5% respectively) per embryo transfer cycles. Fertilization rate is variously affected by the type and degree of sperm defect. No pregnancy was occurred in triple defect group and asthenoteratospermia group. There is no significant increase in the abortion rate in the male factor group. Improvement have to be made with the fertilization rate, as the pregnancy rate per OPU cycle in male factor group is still lower than that of normal group (9.5% vs. 18.3%). In conclusion, IVF can be used as a treatment for male factor infertility and the preparation of the semen sample can be modified to improve sperm recovery and obtain fertilization from abnormal semen samples.

  • PDF

Numerical Analysis on the Heat Transfer Enhancement by Modified Lovour Fin (개량 루버핀에 의한 열전달 성능향상에 관한 연구)

  • Chung, Jae-Dong;Park, Byung-Kyu;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.408-413
    • /
    • 2001
  • Numerical analysis on the three-dimensional laminar flows (Re=1000) and heat transfer in a rectangular channel with punched longitudinal vortex generator have been conducted to explore the heat transfer enhancement and the combined effect of the angle of attack ${\alpha}$ and the lovour angle ${\beta}$. Rectangular winglets have been used as vortex generators. Velocity and temperature fields and spanwise averaged Nu and friction factor were presented. Enhancement of heat transfer and flow loss penalty are evidenced. The results show performance characteristics allowing a reduction in heat transfer surface area of 62% for fixed heat duty and for fixed pumping power compared with that of channel flow without vortex generator. However, adding lovour angle to the vortex generator shows no positive effect on the heat transfer enhancement.

  • PDF