• 제목/요약/키워드: Transfer Conductance

검색결과 64건 처리시간 0.03초

소리를 시각화하는 다양한 방법 (Sound Visualization Gallery: A means to express sound field in space and time)

  • 최정우;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.629-632
    • /
    • 2005
  • What does sound look like if we can see it? It might depend on the acoustic variables we want to see. In this article, we propose various ways to visualize or express sound field in much more intuitive manner. In particular, new visualization schemes that can effectively visualize sound intensity and 3D pressure field are proposed. This allows us to represent sound pressure, particle velocity and acoustic conductance at the same time, even in three-dimensional coordinate. Visualization examples corresponding to the proposed techniques show that we can successfully transfer the meaning of physical variable to visual space.

  • PDF

야외조건하(野外條件下)에서 독일가문비(Picea abies Karst) 침엽(針葉)의 순(純) 광합성률(光合成率)의 단기(短期) 변화(變化)에 대한 실험적(實驗的) 연구(硏究) (Experimental Studies of the Short-Term Fluctuations of Net Photosynthesis Rate of Norway Spruce Needles under Field Conditions)

  • ;;진현오;주영특;정동준
    • 한국산림과학회지
    • /
    • 제88권1호
    • /
    • pp.38-46
    • /
    • 1999
  • 독일 중부(Solling Hills)의 가문비림 임관의 구조적인 수분증산 통도특성은 LE와 H의 유동량으로 측정되고, 1996년 6월중 재배열된 Penman-Monteith 식을 이용하여 SVAT 모형을 설계하여 도출하였다. 또한 SLODSVAT 모형을 통한 전체 임관 내 각 침엽의 연속적인 수분통도성을 평가하여 임관기공의 통도성을 비교하였다. 이와 같은 결과에서 나온 임관 표면 통도성과 유동량을 설계하고, SLODSVAT 모형에 의해 설계된 기공 통도성 사이에서 중요한 차이점을 알 수 있었다. 이 차이점은 산림 임관의 범위내에 빗물리적인 요소에 의해 영향을 받았음을 알 수 있으며, 일반적으로 임관 표변의 통도성은 전체 측정 기간 동안 임관 기공 전도력보다 크게 나타났다. 또한 산림의 전체 증발산량에 대한 하층부의 공헌도는 작았고, 임관의 복사에너지 균형에 의존하지는 않는 것으로 나타났다. 하층부 증발산량의 기각은 독일 가문비림에 대한 임관 표면 전도력의 과대 평가로서 나타난 결과이다.

  • PDF

축열조용 복합 다층 단열재의 단열 성능 연구 (A Study on the Insulation Performance of Composite Multilayer Insulation by Applciation of Heat Storage Tank)

  • 최규홍;황승식;신동훈;박우성;박대웅;손승길;정태용
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.82-87
    • /
    • 2014
  • 적층 단열재(multi-layer insulation, MLI)는 초전도 마그넷과 초전도 전력 케이블과 같은 초전도 응용기기의 냉각에 사용되는 저온유지장치(cryostat)에 외부 열침입을 차단하여 단열성능을 향상시키기 위해 사용된다. 적층 단열재는 인공위성에 사용되는 단열재로 적층단열재를 구성하는 자재의 종류와 적층층수 등에 따라 단열 성능이 변화한다. 본 연구에서는 적층 단열재의 원리를 이용한 축열조용 복합 다층 단열재(composite multilayer insulation, CMI)의 구성 재질 종류를 변경하고 적층 방식을 바꿈으로서 단열 성능이 바뀌는 것을 확인하였다. 실험은 KS C 9805의 방법을 이용하였으며, 복합 다층 단열재의 단열 성능 확인을 위해 동일한 조건의 축열조에 스티로폼을 적용하여 비교하였다. 또한, 실험 결과를 분석하기 위한 방법으로 기존 단열재에 대한 등가 두께를 비교하고 type별 CMI의 열전도율을 구해 비교하였다. 그 결과 복합 다층 단열재의 등가 두께는 스티로폼 보다 작아 동일 두께인 경우 스티로폼 보다 단열성능이 더 우수함을 확인할 수 있었다. 또한, 복합 다층 단열재의 구성 소재 및 적층 방식에 따라 전도, 대류 및 복사와 관련된 값들의 변화가 총괄 열전달계수에 영향을 미치는 것을 확인할 수 있었다.

햄스터 난자에서 존재하는 Chloride 통로 (Identification of Chloride Channels in Hamster Eggs)

  • 김양미;김종수;홍성근
    • 한국수정란이식학회지
    • /
    • 제19권2호
    • /
    • pp.101-112
    • /
    • 2004
  • 본 연구는 포유류인 $Cl^-$통로의 존재 여부를 확인하기 위하여 수행되었다. $Cl^-$통로는 비흥분성 세포에서 용적변화와 pH 조절, 이온운반계 등에 중요한 역할을 수행하므로 활발한 세포분화가 이루어지는 난자의 생존과 기능에 필수적 $Cl^-$통로 존재 여부를 확인하고자 하였다. 단일통로 전류를 기록하는 patch clamp 기법을 이용하였다. 세포외(pipette) 용액을 140 mM NaCl로 하고 세포내(bath) 용액을 70 mM, 140 mM, 280 mM NaCl로 바꾸어 주었을 때, 역전압($E_{rev}$) 은 $Cl^-$평형전압을 반영하는 -9.8${\pm}$0.5mV, 0mV, 11.5${\pm}$0.2mV로 변화하였다(n=4). 이런 결과는 이론치와 약간의 편차를 보이고 있으므로 이를 보정하기 위항 Goldman-Hodgkin-Katz(GHK) 식을 이용한 결과 $Cl^-$에 대한 $Na^+$의 투과성 ($P_{Na}$/$P_{Cl}$/)은 0.25로 추측할 수 있었다. Inside out patch mode에서 Pipette 용액과 bath 용액에 imperment인 NMDG-Cl로 구성하였을 경우 단일 통로가 기록되었다.(n=22). 막전압이 증가함에 따라 전도도(conductance)가 같이 증가하였으며 전류-전압 관계는 outward rectification을 보였다. 이런 특성을 나타내는 단일통로로 전류는 선택적 $Cl^-$통로 차단제인 IAA-94(indanyloxyacetic acid 94)에 의해 농도 의존적으로 차단되었으며 가역적으로 회복되었다. IAA의 $IC_{50}$은 32.6$\mu\textrm{M}$이었다. DIDS(4,4'-diisothiocyan ostillben-2-2'disulfonic acid)에 의해서는 전류크기가 감소 되는 빠른 억제기전을 나타내는 차단효과를 보였으며 시간경과에 따라 seblevel로 감소되는 subconductance block 이 나타났다. 이상의 결과는 햄스터 난자에서 chloride 통로가 존재하여, 물질이동과 pH 조절기능을 나타내는 외향성 전류-전압관계를 보이는 $Cl^-$ 통로의 성상으로 미루어 볼 때 난자의 pH 조절과 용적조절과 같은 생리적 환경 조성에 관여할 것으로 추정된다.

초정밀 스프레이 방법을 이용한 단일벽 탄소나노튜브 pH센서 개발 (Development of single walled-carbon nanotubes based pH sensor using ultra-precision spray method)

  • 권재홍;이경수;이윤희;주병권
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.127-133
    • /
    • 2006
  • Recent studies demonstrated the ability of carbon nanotube (CNT) to promote electron transfer reactions of important compounds and to impart higher stability onto electrochemical sensors. CNT-based sensors measured by hydroxyl radical concentration or pH value suggest great promise for biosensors. This paper describes a new method for fabricating a very simple and inexpensive pH sensor compose of single walled-carbon nanotubes (SW-CNTs) using an ultra-precision spray. CNT-based sensor shows pH sensitivity in buffer solution at different pH range. Our experimental results show the sensor responses to pH buffer solution and the conductance of depends on the pH values. These results support application possibility of SW-CNTs based pH sensor for mass production.

Resistance Distribution in Thin Film Type SFCL Elements with Shunt Layers of Different Thicknes

  • Kim, Hye-Rim;Hyun, Ok-Bae;Lee, Seung-Yup;Yu, Kwon-Kyu;Kim, In-Seon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.41-45
    • /
    • 2003
  • Resistance distribution in thin film type SFCL elements of different shunt layer thickness was investigated. The 300 nm thick film of 2 inch diameter was coated with a gold layer and patterned into 2 mm wide meander lines. The shunt layer thickness was varied by ion milling the shunt layer with Ar ions, and also by having the shunt layer grown in different thickness. The SFCL element was subjected to simulated AC fault current for measurements. It was immersed in liquid nitrogenduring the experiment. The resistance distribution was not affected by the shunt layer thickness at applied voltages that brought the temperature of the elements to similar values. This result could be explained with the concept of heat transfer from the film to the surroundings. The resistance distribution was independent of the shunt layer thickness because thick sapphire substrates of high thermal conductivity dominated the thermal conductance of the elements.

물 부족 현상으로 인한 잔디의 생리학적 반응: 리뷰 (Turfgrass Responses to Water Deficit: A Review)

  • 이준희
    • 아시안잔디학회지
    • /
    • 제25권2호
    • /
    • pp.125-132
    • /
    • 2011
  • 잔디가 건조 스트레스를 받은 상태에서 잔디의 생리학적 메커니즘과 건조 상태에서 식물이 회복하는 생리학적 메커니즘을 보다 깊이 이해하고자 한다. 증산작용과 Stomatal Conductance의 상호 관계로 인한 광합성량의 변화, 식물 세포 내부의 변화, 삼투압 조절능력의 변화, 호르몬의 변화, 단백질 변성 등의 생리학적 반응들을 이해하고 건조 스트레스 상태에서 회복하는데 세포내부의 적응 과정, 뿌리의 반응과 같은 생리학적인 측면에 대해 이해하고 건조 스트레스 상태에서 엽록소가 흡수하고 반사하는 Spectral Reflectance의 변화를 이해하고자 한다. 하지만 건조스트레스로 인한 식물의 생리학적 메커니즘에는 아직 많은 의문점을 가지고 있으며 향 후 외부환경 스트레스에 의한 식물의 Self-defense 메커니즘을 더욱 깊게 이해하여 보다 수준 높은 관리기법들을 연구하는데 초점을 맞추어야 할 것이다.

Highly Sensitive and Transparent Pressure Sensor Using Double Layer Graphene Transferred onto Flexible Substrate

  • Chun, Sungwoo;Kim, Youngjun;Jin, Hyungki;Jung, Hyojin;Park, Wanjun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.229.2-229.2
    • /
    • 2014
  • Graphene, an allotrope of carbon, is a two-dimensional material having a unique electro-mechanical property that shows significant change of the electrical conductance under the applied strain. In addition of the extraordinary mechanical strength [1], graphene becomes a prospective candidate for pressure sensor technology [2]. However, very few investigations have been carried out to demonstrate characteristics of graphene sensor as a device form. In this study, we demonstrate a pressure sensor using graphene double layer as an active channel to generate electrical signal as the response of the applied vertical pressure. For formation of the active channel in the pressure sensor, two single graphene layers which are grown on Cu foil (25 um thickness) by the plasma enhanced chemical vapor deposition (PECVD) are sequentially transformed to the poly-di-methyl-siloxane (PDMS) substrate. Dry and wet transfer methods are individually employed for formation of the double layer graphene. This sensor geometry results a switching characteristic which shows ~900% conductivity change in response to the application of pulsed pressure of 5 kPa whose on and off duration is 3 sec. Additionally, the functional reliability of the sensor confirms consistent behavior with a 200-cycle test.

  • PDF

유한한 열용량의 열원 및 열침 조건에서 열기관의 출력 극대화 (Power Maximization of a Heat Engine Between the Heat Source and Sink with Finite Heat Capacity Rates)

  • 백영진;김민성;장기창;이영수;라호상
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.556-561
    • /
    • 2011
  • In this study, the theoretical maximum power of a heat engine was investigated by sequential Carnot cycle model, for a low-grade heat source of about $100^{\circ}C$. In contrast to conventional approaches, the pattern search algorithm was employed to optimize the two design variables to maximize power. Variations of the maximum power and the optimum values of design variables were investigated for a wide range of UA(overall heat transfer conductance) change. The results show that maximizing heat source utilization does not always maximize power.

Synthesis and Electrochemical Studies of Cu(II) and Ni(II) Complexes with Tetradentate Schiff Base Ligands

  • 조기형;정병구;김정희;전승원;임채평;최용국
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권8호
    • /
    • pp.850-856
    • /
    • 1997
  • A series of tetradentate Schiff-base ligands; 1,3-bis(salicylideneimino) propane, 1,4-bis(salicylideneimino)butane, and 1,5-bis(salicylideneimino)pentane, and their Cu(Ⅱ) and Ni(Ⅱ) complexes have been synthesized. The properties of ligands and complexes have been characterized by elemental analysis, IR, NMR, UV-Vis spectra, molar conductance, and thermogravimetric anaylsis. The mole ratio of Schiff base to metal at complexes was found to be 1 : 1. All complexes were four-coordinated configuration and non-ionic compound. The electrochemical redox processes of the ligands and their complexes in DMF solution containing 0.1 M TEAP as supporting electrolyte have been investigated by cyclic voltammetry, chronoamperometry, differential pulse voltammetry at glassy carbon electrode, and by controlled potential coulometry at platinum gauze electrode. The redox process of the ligands was highly irreversible, whereas redox process of Cu(Ⅱ) and Ni(Ⅱ) complexes was observed as one electron transfer process of quasi-reversible and diffusion-controlled reaction. Also the electrochemical redox potentials of complexes were affected by chelate ring size of ligands. The diffusion coefficients of Cu(Ⅱ) and Ni(Ⅱ) complexes in DMF solution were determined to be 4.2-6.6×10-6 cm2/sec. Also the exchange rate constants were determined to be 3.6-9.7×10-2 cm/sec.