The Design using the reluctance of Reluctive Pressure Transducer (릴럭턴스를 이용한 Reluctive Pressure Transducer의 설계)

  • 조항신;박희성;주형준;성세진;이기홍
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.328-331
    • /
    • 1998
  • Because of the powerful tolerance of overload, dynamic response and anti-erosion, Reluctive Pressure Transducer(RPT), as a measuring element of oil pressure equipment is applied to the measuring system of vessels, air craft. The Electrical reluctance appeared in the pressed diaphragm. To process the reluctance as a electric signal, bridge circuit is used. The design using the reluctance of pressure sensor is described in this paper. For the high efficiency of the sensitive RPT, pressure sensor structure is presented and electrical signal processing is simulated.

  • PDF

The Design and Experiment of Power Factor Improvement Circuit for a Underwater Electro Acoustic Transducer with Low Coupled Dual Resonances (상호 결합이 적은 두 개의 공진점을 갖는 수중용 광대역 전기 음향 변화기를 위한 역률 개선 회로 설계 및 실험)

  • Lim, Jun-Seok;Pyeon, Yong-Guk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.12
    • /
    • pp.967-975
    • /
    • 2013
  • In the design of underwater electro acoustic transducer, power factor improvement circuit is more required rather than impedance matching if the driving power amplifier has little inner resistance. Many research results have been focused on the power matching circuit designing for transferring maximum power in the wideband. There are few results in the designing study on the power factor improvement for the wide band underwater electro acoustic transducer. In this paper, we set up a new design method on the power factor improvement for the wide band electro acoustic transducer, and confirm its feasibility by the experiments.

Design and Fabrication of a 1.75D Ultrasonic Transducer (1.75D 초음파 트랜스듀서의 설계 및 제작)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In this paper, a $64{\times}8$ channel 1.75D ultrasonic transducer made of piezoelectric single crystals was designed, fabricated, and evaluated. First, a structure of the transducer was selected to be suitable for wiring on a planar array, and components were fabricated to correspond to the structure. Detailed structure of the transducer was designed through finite element analyses. As main performance factors, the crosstalk between neighboring elements was reduced through the control of kerf width and material, and desired frequency bandwidth of the transducer was achieved by designing the optimal thicknesses of the piezoelectric single crystal and matching layers. An experimental prototype of the transducer was fabricated following the design, and its performance was measured. Then the experimental results were compared with those of the finite element analysis, which led to the evaluation of the transducer developed in this work.

Design and Test of ElectroMagnetic Acoustic Transducer applicable to Wall-Thinning Inspection of Containment Liner Plates (격납건물 라이너 플레이트 감육 검사를 위한 전자기 초음파 트랜스듀서의 설계 및 성능 평가)

  • Han, Soon Woo;Cho, Seung Hyun;Kang, To;Moon, Seong In
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.46-52
    • /
    • 2019
  • This work proposes a noncontact ultrasonic transducer for detecting wall-thinning of containment liner plates of nuclear power plants by measuring their thickness without physical contact. Because the containment liner plate is designed to prevent atmospheric leakage of radioactive substances under severe nuclear accident, its wall-thinning inspection is important for safety of nuclear power plants. Wall-thinning investigation of containment liner plates have been carried out by measuring their thickness with contact-type ultrasonic thickness gauge by inspectors and needs a lot of time and cost. As an alternative, an electromagnetic acoustic transducer measuring precisely thickness of containment liner plates without any physical contact or couplant was suggested in this research. A transducer generating and measuring shear ultrasonic waves in thickness direction was designed and wave field produced by the transducer was analyzed to verify the design. The working performance of the suggested transducer was tested with carbon steel plate specimens with various thicknesses. The test result shows that the proposed transducer can measure thickness of the specimens precisely without any couplant and implies that swift scanning of wall-thinning of containment liner plates will be possible with the proposed transducer.

Design of Distributed Modal Transducer by Optimizing Gain-weights of Interface Circuit (인터페이스 회로의 이득 최적화를 통한 분포형 모달 변환기의 설계)

  • 김지철;황준석;유정규;김승조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.444-449
    • /
    • 1998
  • A modal transducer in two-dimensional structure can be implemented by varying the distributed transducer's gain spatially. In this paper, a method based on finite element method is developed for optimizing spatial gain distribution of PVDF transducer to create the modal transducer for specific modes. Using this concept, one can design the modal transducer in two-dimensional structure having arbitrary geometry and boundary conditions. As a practical means for implementing this continuous gain distribution without repoling die PVDF film, the gain distribution is approximated by optimizing gain-weights of interface circuit. The whole spatial area of the PVDF film is divided into several electrode segments and the signals from each segment are properly weighted and summed by interface circuit. This corresponds to the approximation of a continuous function using discrete values. The electrode partition is optimized using the genetic algorithm. Gain-weights are optimized using the simplex search method. A modal sensor for first to fourth modes of aluminum plate is designed using PVDF film with gain-weighted interface circuit. Various lamination angles of PVDF film are taken into consideration to utilize the anisotropy of the PVDF film. Performance of the optimized' PVDF sensor is demonstrated by numerical simulations..

  • PDF

Design and Development of a Broadband Ultrasonic Transducer Operating over the Frequency Range of 40 to 75 kHz (40-75 kHz의 주파수 범위에서 동작하는 광대역 초음파 변환기의 설계 및 개발)

  • Lee, Dae-Jae;Kwak, Min Son;Kang, Hee-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.3
    • /
    • pp.292-301
    • /
    • 2014
  • The objective of this study was to design and develop a broadband ultrasonic transducer that has both wide bandwidth and high sensitivity to measure broadband echoes related to identifying fish species. A broadband ultrasonic transducer providing a nearly flat transmitting response band of 40.2-75.5 kHz with a -12 dB bandwidth of 35.3 kHz was achieved by integrating 12 tonpilz transducer elements operating at different resonance frequencies. The average transmitting voltage response, receiving sensitivity, and figure of merit values in this frequency band were 168.4 dB (re $1{\mu}Pa/V$ at 1 m), -196.8 dB (re $1V/{\mu}Pa$), and -28.4 dB, respectively. The results suggest that bandwidth and sensitivity can be widened and improved by adjusting the array pattern and the structure of tonpilz transducer elements.

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.

Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation (치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작)

  • Kim, Na Ri;Jeon, Dae Woo;Kim, Jin Ho;Kim, Sun Woog;Hwang, Jong Hee;Lee, Jeong Bae;Choi, Sung Jae;Im, Dae Jin;Lee, Young Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.

Design of Isolation-Type Matching Network for Underwater Acoustic Piezoelectric Transducer Using Chebyshev Filter Function (체비셰프 필터함수를 이용한 수중 음향 압전 트랜스듀서의 절연형 정합회로 설계)

  • Lee, Jeong-Min;Lee, Byung-Hwa;Baek, Kwang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.491-498
    • /
    • 2009
  • This paper presents the design method of an impedance matching network using an isolation transformer and the Chebyshev filter function for the high efficiency and the flat power driving of an underwater acoustic piezoelectric transducer. The proposed impedance matching network is designed for minimizing the reactance component of transducer and having the flat power response in the wide frequency range. We design a low pass filter with ladder-type circuit using the Chebyshev function as standard prototype filter function. In addition, we design the impedance matching network which is suitable for the equivalent circuit of transducer and the turn ratio of transformer through the bandpass frequency transformation. The proposed method is applied to the simulated dummy load of the tonpilz-type transducer operating in the middle frequency range. The simulation results are compared with the measured characteristics and the validity of the proposed method is verified.

Development of a High-power Ultrasonic System for Sonochemistry Reaction (음향화학 반응용 강력초음파 개발)

  • Lee, Yang-Lae;Kim, Hyun-Se;Baek, Min-Hyuck
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.142-148
    • /
    • 2013
  • High-power ultrasonic promotes a chemical reaction by its own energy, thus it has been used for sonochemistry applications. For example, it has been mostly used for mixing, reaction catalyst, dispersion and disintegration. High-power ultrasonic transducer is made with structure based on a Bolt-clamped Langevin type Transducer (BLT), But it has difficulty in the development because degradation of piezoelectric ceramic by the heat generation of BLT. In this study, for a development of the transducer of 25 kHz and 1000 W used in sonochemistry and industrial cleaning, BLT with a hole in its center and tubular type waveguide of the transducer were designed based on finite element method (FEM). The transducer was fabricated based on the design parameter, and the impedance characteristics are measured experimentally and compared with the numerical results.