References
- S. W. Smith, G. E. Trahey, and O. T. von Ramm, "Twodimensional arrays for medical ultrasound," in Proc. IEEE Ultrason. Symp., 628-628 (1991).
- C. M. W. Daft, D. G. Wildes, L. J. Thomas, L. S. Smith, R. S. Lewandowski, W. M. Leue, K. W. Rigby C. L. Chalek, and W. T. Hatfield, "A 1.5D transducer for medical ultrasound," in Proc. IEEE Ultrason. Symp., 1491-1495 (1994).
- J. Zhang, Q. Xue, and S. Ogawa, "1.5 diemensional arrays for effective dynamic focusing and receiving," in Proc. IEEE Ultrason. Symp., 1531-1534 (1996).
-
P. Tournois, S. Calisti, Y. Doisy, J. M. Bureau, and F. Bernard, "A
$128{\times}4$ channels 1.5D curved linear array for medical imaging," in Proc. IEEE Ultrason. Symp., 1331- 1335 (1996). - D. G. Wildes, R. Y. Chiao, C. M. W. Daft, K. W. Rigby, L. S. Smith, and K. E. Thomenius, "Elevation performance of 1.25D and 1.5D transducer arrays," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 1027-1037 (1997). https://doi.org/10.1109/58.655628
- R. L. Goldberg and S. W. Smith, "Multilayer piezoelectric ceramics for two-dimensional array transducers," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 41, 761-771 (1994). https://doi.org/10.1109/58.308512
- S. S. Brunke and G. R. Lockwood, "Braod-bandwidth radiation pattern of sparse two-dimensional vernier arrays," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 1101- 1109 (1997). https://doi.org/10.1109/58.655635
- P. K. Weber, R. M. Schmitt, B. D. Tylkowksi, and J. Steck, "Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing," in Proc. IEEE Ultrason. Symp., 1503-1506 (1994).
- R. McKeighen, "Finite element simulation and modeling of 2-D arrays for 3-D ultrasonic imaging," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 1395-1495 (1997). https://doi.org/10.1109/58.656643
- W. Lee and Y. Roh, "New design of the kerfs of an ultrasonic two-dimensional array transducer to minimize cross-talk," Jpn. J. Appl. Phys., 49, 07HD06, 2010. https://doi.org/10.1143/JJAP.49.07HD06
- S. H. Lee and Y. R. Roh, "Characterization of all the elastic, piezoelectric and dielectric constants of tetragonal PMN-PT single crystals," Jpn. J. Appl. Phys. 46, 4462-4465 (2007). https://doi.org/10.1143/JJAP.46.4462
- C. S. Desilets, J. D. Fraser, and G. S. Kino, "The design of efficient broad-band piezoelectric transducers," IEEE Trans. on Sonics and Ultrasonics 25, 115-125 (1978). https://doi.org/10.1109/T-SU.1978.31001
- R. E. Davidsen and S. W. Smith, "Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 45, 338-.348 (1998). https://doi.org/10.1109/58.660144
- L. Daane and M. Greenstein, "A demountable interconnect system for a 50 X 50 ultrasonic imaging transducer array," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 978-982 (1997). https://doi.org/10.1109/58.655622
- R. E. McKeighen, "Design guidelines for medical ultrasonic arrays," Proc. SPIE Int'l Symposium on Medical Imaging 3341, 2-18 (1998).
- R. E. McKeighen, "Optimization of broadband transducer designs by use of statistical design of experiments," IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 43, 63-70 (1996). https://doi.org/10.1109/58.484464
Cited by
- Design and Fabrication of a 2D Array Ultrasonic Transducer vol.32, pp.5, 2013, https://doi.org/10.7776/ASK.2013.32.5.393