• Title/Summary/Keyword: Traditional Wall Frame

Search Result 32, Processing Time 0.02 seconds

A Study on the Wall Components of Sarang-taechong in the Upper Class houses of Chosun Dynasty (조선시대 상류주택 사랑대청의 실내입면구성요소에 관한 연구)

  • 오혜경;홍이경
    • Journal of Families and Better Life
    • /
    • v.18 no.2
    • /
    • pp.191-202
    • /
    • 2000
  • The purpose of this study was to clarify the wall components of Sarang-taechong in the upper class houses of Chosun dynasty. Physical trace method was used for this study. The samples were taken from the Sarang-taechong of 6 traditional Korean houses; Yunkyungdang, the ancient Chusa estate, Sunkyojang, Chunghyodang, Yangjindant, Unjorn. The makor findings were summarized as follows; 1) The common components of each wall were pillars, sanginbangs(upper horizontal beams), hainbangs (lower horizontal beams), door and windows. Changbangs(wood eave pieces that suported decoration blocks), changyos(a pice of wood fitted between the tops of pillars and upper tori cross beams), and morums(the top wainscot board laid horizontally between the bottom beam and the bottom portion of a window frame) were additional. 2) The composition of every south wall was symmetrical and the other threes were mixed symmetrical and asymmetrical. 3) The image of wall was classified-fine, strong, and modera e, according to the symmetry or asymmetry of wall composition, the width of each components, the kind of window.

  • PDF

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo;Hwang, Kweon-Hwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.405-413
    • /
    • 2010
  • A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.

Experimental investigation of a frame retrofitted with carbon textile reinforced mortar

  • Sinan M., Cansunar;Kadir, Guler
    • Earthquakes and Structures
    • /
    • v.23 no.5
    • /
    • pp.473-491
    • /
    • 2022
  • The research investigates experimentally the effect of confinement on structural behavior at the ends of beam-column in reinforced concrete (RC) frames. In the experimental study, five specimens consisting of 1/3-scaled RC frames having single-bay, representing the traditional deficiencies of existing buildings constructed without receiving proper engineering service is investigated. The RC frame specimens were produced to represent most of the existing buildings in Turkey that have damage potential. To decrease the probable damage to the existing buildings exposed to earthquakes, the carbon Textile Reinforced Mortar (TRM) strengthening technique (fully wrapping) was used on the ends of the RC frame elements to increase the energy dissipation and deformation capacity. The specimens were tested under reversed cyclic lateral loading with constant axial loads. They were constructed satisfying the weak column-strong beam condition and consisting of low-strength concrete, such as compressive strength of 15 MPa. The test results were compared and evaluated considering stiffness, strength, energy dissipation capacity, structural damping, ductility, and damage propagation in detail. Comprehensive investigations of these experimental results reveal that the strengthening of a brittle frame with fully-TRM wrapping with non-anchored was effective in increasing the stiffness, ductility, and energy dissipation capacities of RC bare frames. It was also observed that the frame-only-retrofitting with an infill wall is not enough to increase the ductility capacity. In this case, both the frame and infill wall must be retrofitted with TRM composite to increase the stiffness, lateral load carrying, ductility and energy dissipation capacities of RC frames. The presented strengthening method can be an alternative strengthening technique to enhance the seismic performance of existing or moderately damaged RC buildings.

Shear Performance of Post and Beam Construction by Pre-Cut Process (프리컷 방식을 적용한 기둥-보 공법의 수평전단내력)

  • Hwang, Kweonhwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1-12
    • /
    • 2007
  • For the purpose of effective utilization of domestic second-grown larch as structural members, post and beam construction applying traditional construction to Japanese larch glulam members was adopted with processing by machine pre-cut method. In general, horizontal shear test by KS F 2154 is conducted to assess the horizontal shear properties of the wooden structure by post and beam construction. The frame was consisted of post and beam member with appropriate fasteners, and members have their own processed parts (notch, hole, etc.) that can be well-connected each other. The shear wall was consisted of the frame with screw-nail sheathed panel (OSB). The results of horizontal shear loading tests without vertical loads conducted on the frame and the shear wall structures, the maximum strengths were about 1.9 kN/m and about 9.7 kN/m, the shear rigidities were about 167 kN/rad, 8198 kN/rad, respectively. The strength proportion of the frame specimen was about 20% of the wall's and about 2% in initial stiffness. Nail failures are remarkable on the shear wall specimen with punching shears and shear failures. The shear load factor for the shear wall specimen by the method of Architectural Institute of Japan was 1.5, which was obtained by the bi-linear method. Loading method should be considered to obtain smooth load-deformation relationship. For the better shear performance of the structures, column base and post and beam connections and sheathed panel should be further examined as well.

The reduced-scale manufacture of a dirt-walled house for the development of a eco-friendly store house (환경친화형 저장고 개발을 위한 흙담집의 축소제작)

  • Kim, Keun-Young;Rhee, Shin-Ho;Song, Chang-Seob;Joo, Ho-Gil;Eom, Seong-Jun;Park, Jong-Beom;Jang, Moon-Ki
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.209-212
    • /
    • 2002
  • The construction method of a dirt-walled house is studied in order to develop eco-friendly store house. A dirt-walled house is constructed based on wall frame(Korean traditional style). The main material is soil (mud).

  • PDF

Development of Frictional Wall Damper and Its Analytical Applications in R/C frame Structures (벽식마찰감쇄기의 개발 및 R/C 골조구조물에의 해석적 적용)

  • 조창근;박문호;권민호;강구수;서상길
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.718-725
    • /
    • 2002
  • A wall type friction damper is newly Proposed in this paper to improve the performance of R/C framed structures under earthquake loads. Although traditional dampers are usually placed as bracing members, the application ot bracing-type dampers into R/C structures is not as simple as those of steel structures due to the connection between R/C members and dampers and the stress concentration in connection region. Proposed damper is consisted of Teflon-sheet slider and R/C shear wall. The damper can also avoid stress concentration and reduce P-Δ effect. To evaluate the performance of proposed damper, nonlinear dynamic analyses are carried on 10 story and 3 bay R/C structures with numerical model for the damper. It is shown that the damper reduces the inter-story drifts and the time-historic responses; especially the damper prevents from forming plastic hinges on the lower columns.

A Study to Analyze the Assembly Process of Precast Concrete Wall Panels in Beam-Column Frame Apartment Buildings (보-기둥구조 PC공동주택 PC벽체의 조립공정 분석 연구)

  • Kim, Ki-Ho;Lee, Bum-Sik;Kim, Min-Jun;Lee, Dong-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.4
    • /
    • pp.495-506
    • /
    • 2024
  • Unlike reinforced concrete(RC) construction, the primary determinant of construction schedule for precast concrete(PC) apartment buildings is the lifting equipment. To establish a dry process-centric construction schedule, this study analyzes the lifting unit process for core, internal, and external PC wall components, which differ from traditional PC components. By examining the assembly process of these wall types, the study aims to determine the construction cycle for a standard floor frame of a PC apartment building. The findings will serve as foundational data for developing construction schedules for PC apartment buildings utilizing PC walls.

A Historical Study on the Specifications of Traditional Handmade Roof-tile (전통수제기와 규격에 관한 고증 연구)

  • Jo, Sang-Sun
    • Journal of architectural history
    • /
    • v.23 no.6
    • /
    • pp.21-26
    • /
    • 2014
  • The purpose of this study is to retrospect the establishment process of specification of modern factory-made traditional Korean roof-tile. Its another purpose is to analyze the specification of watong(瓦桶, a wooden molding frame for roof tile making) which is recorded in the literature of Joseon dynasty. The results of this study are as follows. : First, the specification of modern factory-made Korean roof-tile that currently used was established in 1978. And it did not succeed old traditional specification. Second, in case of construction or repair of main building of palace, it was a principle to use Daewa(大瓦, the big size roof-tile). And Sangwa(常瓦, the ordinary size roof-tile) was used when needed. Also, Jungwa(中瓦, the middle size roof-tile) was used regardless of the size of group building. And Sowa(小瓦, the small size roof-tile) was used in house and wall of royal tomb. Third, it is needed to establish a specification of traditional handmade roof-tile based on the specification of watong through research of the litterateur. So, a standard draft for this was proposed. Finally, one can find the significance that this study has tried to find a specification of traditional roof-tile that can be applied to construction or repair of cultural heritage.

A Study on the Design Change and of the Anglican Church & Rectory in Onsuri, Ganghwa Island (강화 온수리 성공회 성당과 사제관 디자인 변형에 대한 조사연구)

  • 최정신;한주희
    • Korean Institute of Interior Design Journal
    • /
    • no.41
    • /
    • pp.11-18
    • /
    • 2003
  • This study was carried out to find the cases of change in the Anglican Church including its rectory in Onsuri, Gangwha island, which was built in Korean traditional architecture style. The materials used for the study were published books, old photos taken before the change, drawings, and field survey. The result are as followings. 1) Painting concealed natural wooden grain should be removed as well as carpet on the wooden floor. The way of ceiling finishing is to be restored as traditional way. 2) Refer to the rectory, it needs to be restored totally, since it has been changed many times through partial renovation. It lacks unification of design in entire elevation, windows and door. The practical spaces such as indoor flush toilet and boiler room are desirable not to be revealed or designed in harmony with other spaces. 3) Stript flooring in the rectory are to be restored to frame flooring, room finishing including vinyl flooring, vinyl wall paper and moulding along the cornice to the traditional paper finish. Lattice patterns of windows and doors are recommended to be restored according to the traditional design.

A Case Study on the Exhibition Reuse of Korean Traditional Houses designated as Modern Cultural Heritage -Focused on Rhiwhachang.Choi Sunu House- (문화재(文化財) 지정(指定) 근대기(近代期) 한옥(韓屋)의 전시용도(展示用途) 변경사례(變更事例) 연구(硏究) -"이화장"과 "최순우 옛집"을 중심으로-)

  • Kim, Hae-Ri;Lee, Min-Kyoung;Kim, Tai-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.156-161
    • /
    • 2008
  • The registered-properties guideline was adopted to preserve the facade of existing cultural assets with effect and alter the interior space freely. But many problems have been occurred over all the converted buildings with the passing of the years as a result of unfeasible design guidelines. Accordingly, the thesis is to propose the problem and assignment in a setting for a display through the conversion for exhibition of Korean traditional houses designated as modern cultural heritage focused on Riwhachang Choi Sunu House. The results are as follows; The exhibition circulation is continuously connected with each room, considering the previous life-style. The interior design elements are preserved according to the stand-up and sitting style. It is possible to put on one sided wall display in stand up style(Rhiwhachang), and island showcase display in sitting style(Choi Sunu House). And also these apparatus is suitable for the existing window pattern and frame. Therefore, this study is to suggest an assignment of design guideline for exhibition reuse in Korean Traditional Houses as well as the sustainable preservation of cultural assets as modern house.

  • PDF