• Title/Summary/Keyword: Tracking prevention

Search Result 106, Processing Time 0.025 seconds

The Study on the Fire Monitoring Dystem for Full-scale Surveillance and Video Tracking (전방위 감시와 영상추적이 가능한 화재감시시스템에 관한 연구)

  • Baek, Dong-hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2018
  • The omnidirectional surveillance camera uses the object detection algorithm to level the object by unit so that broadband surveillance can be performed using a fisheye lens and then, it was a field experiment with a system composed of an omnidirectional surveillance camera and a tracking (PTZ) camera. The omnidirectional surveillance camera accurately detects the moving object, displays the squarely, and tracks it in close cooperation with the tracking camera. In the field test of flame detection and temperature of the sensing camera, when the flame is detected during the auto scan, the detection camera stops and the temperature is displayed by moving the corresponding spot part to the central part of the screen. It is also possible to measure the distance of the flame from the distance of 1.5 km, which exceeds the standard of calorific value of 1 km 2,340 kcal. In the performance test of detecting the flame along the distance, it is possible to be 1.5 km in width exceeding $56cm{\times}90cm$ at a distance of 1km, and so it is also adaptable to forest fire. The system is expected to be very useful for safety such as prevention of intrinsic or surrounding fire and intrusion monitoring if it is installed in a petroleum gas storage facility or a storing place for oil in the future.

An Instrumentation System Design for Electrical Accident Prevention of 3-Phase Electrical Control Panel (3상 전기제어반 전기사고 예방을 위한 계측시스템 설계)

  • Kwak, D.K.;Choi, J.K.;Kim, J.J.;Kwon, Y.J.;Song, G.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.36-37
    • /
    • 2016
  • The main cause of electrical fires are caused due to short circuit and open circuit. This is generates an instantaneous electric arc or spark accompanied with such electric faults. These arcs generate a pressed wire, contact badness, and a weakness in the wire coating etc.. This research proposes a protection circuit to prevent open-phase accident due to contact failure of electromagnetic contactor, tracking arc fault, open-phase within the three-phase electrical control panel which is the most commonly applied in the industry. The proposed circuit also alarms and cuts off of power system when electrical faults occurs. In addition, the proposed circuit is validated by various electric accident simulator.

  • PDF

A study on the detection of poor contact and arcing fault using a fuzzy logic (퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구)

  • Kim, Hyun-Woo;Kim, In-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF

A Study on Requirement Analysis of Unmanned Combat Vehicles: Focusing on Remote-Controlled and Autonomous Driving Aspect (무인전투차량 요구사항분석 연구: 원격통제 및 자율주행 중심으로)

  • Dong Woo, Kim;In Ho, Choi
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.18 no.2
    • /
    • pp.40-49
    • /
    • 2022
  • Remote-controlled and autonomous driving based on artificial intelligence are key elements required for unmanned combat vehicles. The required capability of such an unmanned combat vehicle should be expressed in reasonable required operational capability(ROC). To this end, in this paper, the requirements of an unmanned combat vehicle operated under a manned-unmanned teaming were analyzed. The functional requirements are remote operation and control, communication, sensor-based situational awareness, field environment recognition, autonomous return, vehicle tracking, collision prevention, fault diagnosis, and simultaneous localization and mapping. Remote-controlled and autonomous driving of unmanned combat vehicles could be achieved through the combination of these functional requirements. It is expected that the requirement analysis results presented in this study will be utilized to satisfy the military operational concept and provide reasonable technical indicators in the system development stage.

Life Prevention Service for COVID-19 using Machine Learning (머신러닝을 활용한 코로나 바이러스 생활방역 서비스)

  • Lee, Se-Hoon;Kim, Young-jin;Jeong, Ji-Seok;Seo, Hee-Ju;Kwon, Hyeon-guen
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.07a
    • /
    • pp.95-96
    • /
    • 2020
  • 본 논문은 발열 검사시에 QR코드를 이용해 1차적인 본인인증 단계 후 K-NN알고리즘을 통한 얼굴인식으로 2차적인 본인인증 을 거친후 비대면식으로 발열검사가 가능한 방법을 제시하였다. 이를 통해서 추적관리 뿐만 아니라 CCTV영상을 통하여 확진자 발생시 인접 인원 추적까지 가능하고, 신속한 추적관리가 가능하게 제공하였다.

  • PDF

Spatial Analysis to Capture Person Environment Interactions through Spatio-Temporally Extended Topology (시공간적으로 확장된 토폴로지를 이용한 개인 환경간 상호작용 파악 공간 분석)

  • Lee, Byoung-Jae
    • Journal of the Korean Geographical Society
    • /
    • v.47 no.3
    • /
    • pp.426-439
    • /
    • 2012
  • The goal of this study is to propose a new method to capture the qualitative person spatial behavior. Beyond tracking or indexing the change of the location of a person, the changes in the relationships between a person and its environment are considered as the main source for the formal model of this study. Specifically, this paper focuses on the movement behavior of a person near the boundary of a region. To capture the behavior of person near the boundary of regions, a new formal approach for integrating an object's scope of influence is described. Such an object, a spatio-temporally extended point (STEP), is considered here by addressing its scope of influence as potential events or interactions area in conjunction with its location. The formalism presented is based on a topological data model and introduces a 12-intersection model to represent the topological relations between a region and the STEP in 2-dimensional space. From the perspective of STEP concept, a prototype analysis results are provided by using GPS tracking data in real world.

  • PDF

Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference (GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Finger Printing Based Radio Positioning Scheme for Maritime Safety (수상 안전을 위한 Finger Printing 기반 무선 위치추적 기술)

  • Seok, Keun Young;Ryu, Jong Yeol;Lee, Jung Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1001-1008
    • /
    • 2018
  • In this paper, we propose an efficient location tracking scheme using wireless signals for various situations in marine environment that requires location information for many reasons such as lifesaving, accident prevention, and facility management. Our proposed location tracking scheme not only monitors user's location, but also minimizes the risk under the user's limited battery power budget. The position of a user can be obtained at base stations from the strengths of the received signals from the user. In this case, it may require to prevent the user from getting out of the predetermined safe area. For each location in the safe area, we define a risk function, which is influenced by many factors such as location accuracy, depth, flow rate, and geometry. Our proposed scheme is based on finger printing technique and aims at minimizing the average risk of each user in the safe area.

A Study on Long Range Image Monitoring and Tracking System Using Laser Range-Gate Method in Inclement Weather Conditions (악천후 상황에서 Laser Range-Gate 방식을 이용한 원거리 영상 감시 및 추적 시스템에 대한 연구)

  • Oh, Sung-Kwun;Yoo, Sung-Hoon;Ku, Kyong-Wan;Kim, Su-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.257-263
    • /
    • 2013
  • In case of image observation equipments, CCTV for short distance visual field is usually installed and operated mostly as the means of crime-prevention. However, the extensive demand for monitoring problems in case of the increase in intelligent crimes and disasters has led to the necessity of the development of long-distance observation equipments embedded with Night View functions. In case of the Night View equipments, the relevant market is set up to be focused mostly on Thermal Observation Device(hereinafter, TOD), but some shortcomings such as the limitation of image visibility and excessive maintenance cost, etc. have actually caused the necessity of new long distance Night View equipment. Moreover there might follow lots of difficulties in long-distance visualization in the event that irregular reflection is generated by minute particles in the atmosphere such as fog, smog, and dust, etc. These factors are motivate the work presented in this study. Our study is aimed at the realization of Pulsed Laser Illuminator and newly proposed Range-Gated image acquisition technology. And also the implementation of Tracker for continuous trace of the objects of interest from the obtained sequence images.

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.