• 제목/요약/키워드: Tracer gas measurement

검색결과 22건 처리시간 0.023초

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구 (A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan.)

  • 이광명;함진식
    • 한국주거학회논문집
    • /
    • 제16권1호
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

가스를 연료로 사용한 주방에서의 오염물질 발생 특성에 대한 연구 (A Study on the Occurrence Character of Contaminant in the Kitchen that Use Gas Fuel)

  • 박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2001년도 학술발표대회논문집
    • /
    • pp.77-82
    • /
    • 2001
  • This paper is contents that measure the ventilation rates and temperature by driving condition of exhaust fan, vapor, contaminant occurrence amount of carbon dioxide etc. In kitchen of apartment house. The ventilation rates in the apartment kitchen measured by Tracer Gas Method. And, temperature of when cook by gas table hood lower part 10cm and floor upside 10cm of kitchen central part, 120cm, 210cm heights measure. As ventilation rates measurement result, ventilation number of times was 0.7(number of times/hour) when did not to operate exhaust fan. but we were measured by 2.3(number of times/hour) when drove strongly. As temperature measurement result at cooking by gas table, temperature showed highest in hood lower part 10cm of case that do not operate exhaust fan. Temperature at kitchen central was most low in 10cm height in talc floor, and 210cm were measured highest. Concentration of carbon dioxide is very high by 4,350ppm after measurement time 10 minutes in state who do not operate exhaust fan at cooking by gas table.

  • PDF

Modified Gas Tracer Method를 이용한 하천의 재폭기계수 (Field Measurement Methods of Stream Reaeration Coefficient - Modified Gas Tracer Method -)

  • 조영준;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.547-551
    • /
    • 1998
  • Reaeration coefficient is the physical absorption of oxygen from the atmosphere by water. It is the most important natural means by which a stream replaces the oxygen consumed in the biodegradation of organic wastes, and the rate constant describing this process is the reaeration coefficient, It. Reaeration coefficient is the dominant parameter affecting the use of water quality model. Therefore accurate estimation of the reaeration coefficient is essential for optimum water quality management. There is several method to estimate stream reaeration coefficient. In this study, it would be concluded that SI-peak method is of practical use when applied to small stream, and CRI method is adequate to large stream.

  • PDF

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.

공동주택 자연침기현상 측정연구 (A Study of Natural Infiltration Phenomenon in Apartment Buildings)

  • 정형호;송준원;홍구표;박철용;김진업;양경모;이복만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.944-949
    • /
    • 2006
  • An infiltration was realized as an important part of ventilation to change fresh air with contaminated air in a house. In this study, it was measured the infiltration in new apartment buildings according to Seasons, height etc. We measured the infiltration by using tracer gas method and did for 24hours. To quantify the infiltration, Sulfur Hexafluoride($SF_6$) gas was used. The Constant Concentration was conducted during experimental process and the concentration of the gas was measured with a gas monitor. In the results of the measurement, the infiltration were appeared over 0.6 ACH in winter and about 0.2 ACH in summer and autumn. Also the infiltration were measured more highly at high and low stories than middle stories in winter.

  • PDF

토양 내 PCE 제거과정에서 가스 분배추적자기법을 이용한 공기노출 PCE의 잔류량 검출 (Measurement of Gas-Accessible PCE Saturation in Unsaturated Soil using Gas Tracers during the Removal of PCE)

  • 김헌기;권한준;송영수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권5호
    • /
    • pp.42-52
    • /
    • 2011
  • In this laboratory study, the changes in gas-exposed perchloroethene (PCE) saturation in sand during a PCE removal process were measured using gaseous tracers. The flux of fresh air through a glass column packed with PCEcontaminated, partially water-saturated sand drove the removal of PCE from the column. During the removal of PCE, methane, n-pentane, difluoromethane and chloroform were used as the non-reactive, PCE-partitioning, water-partitioning, and PCE and water-partitioning tracers, respectively. N-pentane was used to detect the PCE fraction exposed to the mobile gas. At water saturation of 0.11, only 65% of the PCE was found to be exposed to the mobile gas prior to the removal of PCE, as calculated from the n-pentane retardation factor. More PCE than that detected by n-pentane was depleted from the column due to volatilization through the aqueous phase. However, the ratio of gas-exposed to total PCE decreased on the removal of PCE, implying gas-exposed PCE was preferentially removed by vaporization. These results suggest that the water-insoluble, PCE-partitioning tracer (n-pentane in this study), along with other tracers, can be used to investigate the changes in fluid (including nonaqueous phase liquid) saturation and the removal mechanism during the remediation process.

기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구 (A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System)

  • 구재현
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 실내 쾌적성 제어를 위하여 룸 에어컨의 환기성능을 분석한다. 실험장치는 환경공조챔버, 룸 에어컨, 추적가스 측정시스템, 급기팬과 제어기로 구성된다. 환기성능은 ASTM Standard E741-83 기준에 근거하여 환경공조챔버 내 CO2 추적가스기법을 사용한 체강법에 의해 재실자와 급기 환기량에 따라 평가된다. 급기 환기량 증가에 따라 환기성능이 증가함을 파악하였으며 재실자가 없는 경우 CO2 가스는 빠르게 감소하며 이때의 환기성능은 55%까지 증가한다. 그리고 1명의 재실자가 있는 경우 1시간 경과후 급기량 570 lpm에서 환기성능은 자연감쇠와 비교하여 25%까지 증가한다. 실험 데이터를 사용하여 환경공조챔버 내 룸 에어컨의 환기성능 모델링을 도출하였다.

난류 확산화염의 계측 위치에 따른 화염자발광 특성에 대한 연구 (A Study on chemiluminescence characteristics of a turbulent flame for different measurement location)

  • 권민준;이창엽;김세원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.219-222
    • /
    • 2014
  • The flame chemiluminescence is a good tracer of flame statement. In this study, the characteristics of flame chemiluminescence($OH^*$, $CH^*$, ${C_2}^*$) according different measuring locations using photomultiplier(PMT), spectrometer and CCD camera. Measurements are made for $OH^*$, $CH^*$, ${C_2}^*$ radicals in gas & light oil diffusion flames. At turbulent nonpremixed combustion mode, the equivalence ratio is varied. The experimental results showed that measuring location affects the result of flame chemiluminescence.

  • PDF

Measurement of Indoor Air Quality for Ventilation with the Existence of Occupants in Schools

  • Shin Hee-Soo;Lee Jai-Kwon;Ahn Young-Chull;Yeo Chang-Shin;Byun Sang-Hyun;Lee Jae-Keun;Kang Tae-Wook;Lee Kam-Gyu;Park Hyo-Soon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1001-1005
    • /
    • 2005
  • This paper evaluates the performance of ventilation for the removal of indoor pollutants as a function of ventilation rate and the number of occupants in a test room and school classroom. An experimental apparatus consists of a test room, a tracer gas supply system, a gas detector, and a fan for ventilation air supply with a controller. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 using $CO_{2}$ gas as a tracer gas in the test room of 35 $m^{3}.$ For the ventilation air flow rate of 1.0 ACH, a recommended ventilation flow rate of Korea school standard for acceptable indoor air quality in the case of one person, CO_{2}$ gas concentration decreases up to $55{\%}$ within 50 minutes without occupancy and increases up to $75{\%}$ in the case of one occupant. Also indoor air quality at the school classroom is investigated experimentally.