• 제목/요약/키워드: Tower design

검색결과 639건 처리시간 0.027초

폴리머 절연암을 이용한 송전선로 전압 승압에 관한 연구 (A Study on the Voltage Upgrading of Transmission Lines using Polymer Insulation Arm)

  • 이원교;이정원;강연욱;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.870-878
    • /
    • 2009
  • The large increase in the use of electricity has resulted in an ever-growing electric power demand. It has created the need for the construction of power transmission facility located close to the load centers and it also has to require wide right-of-way and large lots, that are not always available, for especially the installation of the towers. The difficulties in acquiring right-of-way have put pressure on energy companies to either upgrade a line on an existing right-of-way to higher voltage or build a new line on a narrow right-of-way. This paper presents the design of a compact tower with polymer Insulation arm, in order to reduce the separation between phases. the compact tower can be built on a narrow right-of-way. the compact tower can be designed based on 345 kV Tower regarding electrical clearances and right of way, therefore the conventional 154 kV Tower can be upgrading transmission line voltages have moved to 345 kV levels.

A simplified design approach for modelling shear force demand on tower walls supported on a transfer structure in regions of lower seismicity

  • Yacoubian, Mehair;Lam, Nelson;Lumantarna, Elisa;Wilson, John L.
    • Earthquakes and Structures
    • /
    • 제15권1호
    • /
    • pp.97-111
    • /
    • 2018
  • Buildings featuring a transfer structure can be commonly found in metropolitan cities situated in regions of lower seismicity. A transfer structure can be in the form of a rigid plate or an array of deep girders positioned at the podium level of the building to support the tower structure of the building. The anomalous increase in the shear force demand on the tower walls above the podium is a major cause for concern. Design guidance on how to quantify these adverse effects is not available. In this paper a simplified method for quantifying the increase in the shear force demand on the tower walls is presented. In view of the very limited ductile nature of this type of construction the analysis presented herein is based on linear elastic behaviour.

휴대폰 애플리케이션을 통한 타워전망대 동적특성 분석 (Analysis on Dynamic Characteristics of an Observatory Tower by Using Mobile-phone Application)

  • 문상현;윤성원
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.47-54
    • /
    • 2016
  • It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.

OPTIMAL DESIGN ALGORITHM OF THE FOUNDATION OF TOWER CRANES

  • Kim, Sun-Kuk;Kim, Jang-Young;Ryu, Sang-Yeon
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1047-1052
    • /
    • 2009
  • As buildings nowadays become taller in height and larger in size the safety review of lifting plan takes larger portion in construction project management. However, the cost and safety in lifting plan have a contradictory effect on each other. Therefore, an optimization algorithm needs devising as a solution of the contradictory problem. In many cases at construction sites, selections and stability review of tower cranes are assigned to equipment suppliers or field managers, which cause the problems in safety and cost of the projects. To improve the part of the current situation, a study on the optimization algorithm for designing the foundation of tower cranes is conducted in this study, which can be utilized by equipment suppliers or field managers to check the stability of tower cranes easily and promptly without substantial knowledge.

  • PDF

파랑하중에 대한 Guyed Tower의 동적해석 (Dynamic Analysis of Guyed Tower Subjected to Wave Forces)

  • 류정선;윤정방
    • 대한토목학회논문집
    • /
    • 제5권4호
    • /
    • pp.87-94
    • /
    • 1985
  • 본 논문에서는 최근에 개발된 심해용 구조물인 guyed tower 의 동력학적 해석방법과 이의 주요 설계인자인 guying system 의 강성 및 구조물기초부에서의 회전강성이 구조물의 거동에 미치는 영향에 대하여 연구하였다. 해석기법으로는 guying system 의 초기강성을 사용하여 구한 자유진동 모우드의 중첩법을 주로 고찰하였으며, 그 결과를 몇가지의 다른방법에 의한 결과와 비교검토하였다. 예제해석은 세계최초의 guyed tower 인 Lena tower 를 표준구조물로 택하여 수행되었다.

  • PDF

백연 방지를 위한 NWD냉각탑의 성능해석에 관한 수치해석적 연구 (A Numerical Study on the Performance Analysis of the Plume Abatement NWD Cooling Tower)

  • 최창혁;최영기;소헌영
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1049-1058
    • /
    • 2001
  • The performance and design analysis for a NWD cooling tower using a combined wet and dry type fill are numerically investigated and compared with the experimental results. The Stoecker's method is applied to the wet section and LMTD or NTU-Effectiveness method to the wet and dry sections. The efficiency ratio of the NWD cooling tower to a wet type crossflow cooling tower is 59.34%. The predicted result shows a good agreement with the experimental data within 1.4% error. Plume abatement is far better with a NWD cooling tower than a counterflow cooling tower. It costs less than a conventional wet/dry tower because the finned exchanger is eliminated. This method also leaves out complexity in structure and Intricacy in operation.

  • PDF

Key Technologies for Super Tall Building Construction: Lotte World Tower

  • Kim, Gyu Dong;Lee, Joo Ho
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.205-211
    • /
    • 2016
  • This paper addresses the key technologies for supertall building construction based on the Lotte World Tower project in Korea. First, the mega-mat foundation construction technologies are shown, including ultra-low heat concrete, heat of hydration control programs, and the logistics plan. Then, high strength concrete technologies of 50~80 MPa are introduced and discussed within the context of the highest pumping record in Korea at 514.25 meters. Structural design concepts of gravity load and lateral force resistance systems are introduced, along with surveying systems using GNSS and temporary installation plans of special heavy equipment like tower cranes, hoists, and high pressure concrete pumps. If it is possible to coordinate these key technologies and others, optimizing for the building's design and construction, supertall building construction can be successfully completed.

Brief description of the Design and Construction of the Burj Dubai Project, Dubai, UAE.

  • Abdelrazaq Ahmad K.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.9-14
    • /
    • 2005
  • The Burj Dubai Project will be the tallest structure ever built by man; when completed the tower will be more than 700 meter tall and more than 160 floors. The early integration of aerodynamic shaping and wind engineering considerations played a major role in the architectural massing and design of this residential tower, where mitigating and taming the dynamic wind effects was one of the most important design criteria. This paper presents a brief overview of the structural system development and considerations of the tower and discusses the construction planning of the key structural components of the tower.

  • PDF

하나로 2차 냉각탑의 냉각능력 평가 (Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO)

  • 박용철;우종섭;조영갑;류정수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

Challenges in the Architectural Technical Design of the New Generation of Supertall Buildings

  • Weismantle, Peter A.
    • 국제초고층학회논문집
    • /
    • 제7권1호
    • /
    • pp.85-93
    • /
    • 2018
  • The design of a supertall building poses many challenges to the architect and engineer. Using Jeddah Tower as a case study; this paper intends to discuss a few of those challenges specifically related to the arrangement of programmed spaces in the tower, their functional connection by means of the vertical transportation system and physical connection with shafts which introduces the potential for stack effect in the building. The measures applied in response to and mitigation of these issues are discussed.