Analysis on Dynamic Characteristics of an Observatory Tower by Using Mobile-phone Application  

Moon, Sang-Hyouen (Seoul National University of Science and Technology, School of Architecture)
Yoon, Sung-Won (Seoul National University of Science and Technology, School of Architecture)
Publication Information
Journal of Korean Association for Spatial Structures / v.16, no.2, 2016 , pp. 47-54 More about this Journal
Abstract
It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.
Keywords
Tower; Mobile-phone; Vibration measurement; Ambient vibration; Natural frequency;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Son In-Sung, Shim Jae-Hyun, A Study on the Situation about Architectural Planning in Observatory Tower, Journal of KSSC, Vol.30, No.12, pp. 21-30, 2014
2 Yoon Sung-Won, Joo Young-Kyu, Natural Frequency of Tall building Through Ambient Vibration Measurement, Journal of KSSC, Vol.15, No.2, pp. 117-124, 2003
3 Gu Hye-Jin, Kim Hong-Jin, Natural period and Damping ratio of RC buildings in Korea, Gyeongbuk University master's theis, 2014.12
4 Ellis, R, Full-scale Measurements of Dynamic Characteristics of Buildings in the UK, Journal of Wind Engineering and Industrial Aerodynamics, Vol 59, pp. 365-382, 1998
5 Suda Kenichi et al, Damping Properties of Buildings in Japan, Journal of Wind Engineering and Industrial Aerodynamics, September, pp 383-392, 1995
6 Lagomarsino, S., Forcast model for damping and Vibration Periods of Buildings, Journal of Wind Engineering and Industrial Aerodynamics, pp 221-239, 1998
7 Do Ki-Young, Yoon Sung-Won, Analysis of Natural Frequency through Vibration Measurement of Foot-bridge, SNUST master's thesis, 2014.12
8 Yoon Sung-Won, Moon, Sang-Hyouen, Ambient Vibration Measurement of Buildings Horizontal Vibration Using a Mobile Phone Application, Journal of KSSC, Vol.15 No.3, pp. 77-83, 2015
9 Jung Young-Seok, Moon Sang-Hyun, Yoon sung-won, Ambient Vibration Measurement of High-Rise Building by Mobile Phone, Proceedings of KASS Vol. 11, No.1, pp.112-113, 2015
10 Architectural Institute of Japan (AIJ), Damping in buildings, Tokyo, 2000
11 Ellis, On Predictiong the response of Tall Buildings to Wind Excitation, Journal of Wind Engineering and Industrial Aerodynamics, pp. 173-182, 1983
12 EUROCODE 1, Basis of Design and Actions on Structures, Part 2-4, wind Action, CEN/TC 250/SC 1, Steering Panel Draft, 1994
13 Jeong Jin-Hee, Kim Hong-Jin, Choi Sun-Young, Comparison of Design Code Damping Formulae and Measured Damping Ratios of Tall Buildings under Wind Loads, Journal of AIK, Vol29. No.4, pp. 11-18, 2015