DOI QR코드

DOI QR Code

Analysis on Dynamic Characteristics of an Observatory Tower by Using Mobile-phone Application

휴대폰 애플리케이션을 통한 타워전망대 동적특성 분석

  • Moon, Sang-Hyouen (Seoul National University of Science and Technology, School of Architecture) ;
  • Yoon, Sung-Won (Seoul National University of Science and Technology, School of Architecture)
  • 문상현 (서울과학기술대학교 건축과) ;
  • 윤성원 (서울과학기술대학교 건축학부)
  • Received : 2016.02.15
  • Accepted : 2016.05.04
  • Published : 2016.06.15

Abstract

It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.

Keywords

References

  1. Son In-Sung, Shim Jae-Hyun, A Study on the Situation about Architectural Planning in Observatory Tower, Journal of KSSC, Vol.30, No.12, pp. 21-30, 2014
  2. Yoon Sung-Won, Joo Young-Kyu, Natural Frequency of Tall building Through Ambient Vibration Measurement, Journal of KSSC, Vol.15, No.2, pp. 117-124, 2003
  3. Gu Hye-Jin, Kim Hong-Jin, Natural period and Damping ratio of RC buildings in Korea, Gyeongbuk University master's theis, 2014.12
  4. Ellis, R, Full-scale Measurements of Dynamic Characteristics of Buildings in the UK, Journal of Wind Engineering and Industrial Aerodynamics, Vol 59, pp. 365-382, 1998
  5. Suda Kenichi et al, Damping Properties of Buildings in Japan, Journal of Wind Engineering and Industrial Aerodynamics, September, pp 383-392, 1995
  6. Lagomarsino, S., Forcast model for damping and Vibration Periods of Buildings, Journal of Wind Engineering and Industrial Aerodynamics, pp 221-239, 1998
  7. Do Ki-Young, Yoon Sung-Won, Analysis of Natural Frequency through Vibration Measurement of Foot-bridge, SNUST master's thesis, 2014.12
  8. Yoon Sung-Won, Moon, Sang-Hyouen, Ambient Vibration Measurement of Buildings Horizontal Vibration Using a Mobile Phone Application, Journal of KSSC, Vol.15 No.3, pp. 77-83, 2015
  9. Jung Young-Seok, Moon Sang-Hyun, Yoon sung-won, Ambient Vibration Measurement of High-Rise Building by Mobile Phone, Proceedings of KASS Vol. 11, No.1, pp.112-113, 2015
  10. Architectural Institute of Japan (AIJ), Damping in buildings, Tokyo, 2000
  11. Ellis, On Predictiong the response of Tall Buildings to Wind Excitation, Journal of Wind Engineering and Industrial Aerodynamics, pp. 173-182, 1983
  12. EUROCODE 1, Basis of Design and Actions on Structures, Part 2-4, wind Action, CEN/TC 250/SC 1, Steering Panel Draft, 1994
  13. Jeong Jin-Hee, Kim Hong-Jin, Choi Sun-Young, Comparison of Design Code Damping Formulae and Measured Damping Ratios of Tall Buildings under Wind Loads, Journal of AIK, Vol29. No.4, pp. 11-18, 2015

Cited by

  1. The Evaluation of Effectiveness on Horizontal Ambient Vibration Measurement of Tall Building Using Wireless MEMS Sensor vol.18, pp.2, 2018, https://doi.org/10.9712/KASS.2018.18.2.51