• 제목/요약/키워드: Touch Voltage

검색결과 99건 처리시간 0.039초

접지계에서 위험전압의 측정과 분석 (Measurement and Analysis of Risk Voltages in a Grounding System)

  • 진창환;박대원;서재석;길경석;길형준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3099-3103
    • /
    • 2011
  • In measurement of risk voltages; the step and touch voltage, the distance between the current electrode and the ground electrode recedes up to several hundred meters as the scale of grounding system increases. This paper dealt with the measurement method of risk voltage in a restricted space. The risk voltage was analyzed depending on the distance and the direction of the current electrode from the ground electrode in a $10[m]{\times}10[m]$ mesh grounding system. The average value of risk voltages measured at a point 20 [m] away from the current electrode was deviated below 5 [%] from that measured at 100 [m] point. Consequently, the evaluation of risk voltage of a large-scale grounding system buried in a spatially restricted place is available if the current electrode is installed in symmetry to the ground electrode.

  • PDF

터치키 응용을 위한 풀 디지털 정전용량 센서 (A Full Digital Capacitive Sensor for Touch Key Applications)

  • 성광수;이무진
    • 대한전자공학회논문지SD
    • /
    • 제46권6호
    • /
    • pp.25-30
    • /
    • 2009
  • 본 논문에서는 터치키에 응용할 수 있는 풀 디지털 방식의 정전용량 센싱 기법을 제안한다. 제안된 회로는 측정하고자 하는 정전용량 두 개와 두 정전용량 사이 저항으로 구성된다. 각 정전용량과 저항으로 지연을 측정한 후 두 지연의 차이로 측정하고자 하는 두 정전용량의 차이를 구하는 방식으로 동작전압, 온도, 습도와 같은 동작환경변화의 영향을 완화시킬 수 있는 장점이 있다. 실험결과 제안된 방식의 정전용량 해상도가 1.02pF이어서 터치키에 적용할 수 있음을 보였다.

측정방식에 따른 Tabbing Cell에서의 전기적 특성 분석 (Analysis on Electrical Characteristics of Tabbing Cells According to Measurement Methods)

  • 최은지;김경수;강기환;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1304-1305
    • /
    • 2011
  • In this study, tabbing cell samples in the soft touch method are compared samples according to soldering voltage conditions. Series resistance and power loss is measured by two measurement method. As a result, probe measurement method was found optimized soldering voltage optimized according to voltage condition and clamp measurement method was not difference. The purpose of this paper is to analysis the principle of measurement method.

  • PDF

제작된 수직 마이크로미러 어레이의 특성 측정 (Characteristics measurement of fabricated micromirror array with vertical springs)

  • 신종우;김용권;박진구;신형재;문재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.618-620
    • /
    • 1997
  • A $50{\times}50{\mu}m^2$ aluminum micromirror array is fabricated using shadow evaporation process. The fabrication process is very simple with use of shadow evaporation process, and the micromirror array has a high fill-factor. The static and dynamic characteristics such as deflection angle vs. applied voltage, step response, and frequency response are measured using a contact free optical measurement technique. The downward threshold voltage was 8 V, step response time was $13.5{\mu}s$ when 32 V step voltage applied, and a resonance observed at 11kHz. The lifetime of micromirror with anti-stiction coating was tested and micromirror operated successfully over 200 million cycles of touch-down operations.

  • PDF

독립 전원설비에서의 접지방법 개선에 관한 연구 (A Study of Ground System improvement on Isolated Power Generation)

  • 류보혁;남택주;김정훈
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.96-102
    • /
    • 2001
  • In construction sites, portable generators and electrical equipments cause frequently electrical accidents due to the poor condition of their usage. However, there are very few technical guidelines on these equipments even though they have serious accident causing potentiality. In order to reduce such accidents in practical and economical, grounding methods are studied in this paper as the countermeasure of electrical accidents. Several Korean national standards and international standards regarding three grounding types are compared each other, and some prevention means of electrical accidents are reviewed in this study. This paper presents the most effective grounding methods by assuming the WCS with the isolated power systems.

  • PDF

전력계통 안정화를 위한 전압보상설비 운용 방안 (Operation method of Voltage Compensation Devices for power system stability)

  • 안창한;백영식
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.523-528
    • /
    • 2015
  • A new algorithm for a coordinative control method is proposed with respect to voltage control and system stabilization of local substations. This is accomplished using control cooperation between a static synchronous compensator (STATCOM) and the existing voltage compensation equipment in the steady state and emergency state of a power system. A real-time system analysis was developed by combining a system analysis program with InTouch, which has primarily been used in factory automation for verification. PSS/E was used for the load flow calculation software, Python for language, Intouch as an HMI program, and MS SQL for the database. To test this system, the system in the vicinity of the Migeum and the Migeum substations was modeled and simulated.

국내환경을 고려한 loop impedance 특성 분석 (Analysis of loop impedance characteristic based on korea internal electrical environment)

  • 정진수;한운기;김오환;안재민;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2174_2175
    • /
    • 2009
  • This Paper present about loop impedance characteristic based on korea internal electrical environment. Analysis parameters were touch voltage, electrical shock current and human body resistance. Result, For protect of electrical shock must measuring of loop impedance. And current capacity & loop impedance are must important parameters.

  • PDF

도시철도 통합접지망에서의 위험전압에 따른 연접접지봉의 최적 분기간격에 관한 연구 (A Study on the Optimal Divergence Spacing of the Connecting Grounding Rod to the Dangerous Voltage in the Global Earthing Network of Urban Rail Transit)

  • 정호성;박영;김형철;김진희;김재문;조대훈
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1374-1379
    • /
    • 2012
  • Urban rail transit tends to global grounding system in order to control ground potential rise and potential differences between electric equipments. In addition, global grounding system can discharge the large capacity surge current to the ground safely. Since some railway electric equipments are installed all section of line, the global grounding system connected with the connecting grounding wire is more effectively. However, if the fault occurred in the connecting grounding wire area, some dangerous voltage is generated. So, the installation of additional grounding rod will be required. In this study, the global grounding system is simulated using CDEGS program to analyze the divergence spacing of additional ground rod depending on dangerous electric potential characteristics. Grounding net of the each station is modelled in depending on the size of the platform, and the spacing of the connecting grounding rod are compared 50m, 100m, 250m and 400m. Simulation results considering of earth resistivity and underground condition of the connecting grounding wire, spacing of the connecting grounding rod is that less than 250m to spacing of the ground rod was appropriately confirmed.

인체감전 안전기준에 관한 최근 국제규격의 동향 (Recent Trend of International Standards on the Safety Criteria for Electric Shock Protection)

  • 이종철;김한수;이주철;강성만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.189-193
    • /
    • 2007
  • The grounding of an electrical system is one of the essential elements for public safety. Domestic practice of grounding system design has been to get grounding resistance values which are classified by facilities or equipment in the regulations. But the concept of grounding system design of IEC is, as a main factor of safety index, to consider touch voltage and step voltage instead of the resistance value itself. Recently IEC actively develops or revises safety related standards which are essential for the grounding system performance. In this paper, we present the recent trend of the international standards on the safety criteria for Electric Shock Protection.

  • PDF

국제 규격 접지시스템의 국내 적용을 위한 시뮬레이션 기반의 안전도 평가 방안 (Method for Safety-Decision to Apply International Standard Grounding Systems to Domestic Power System by Computer Simulation)

  • 이순;김정훈;박정욱
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.344-353
    • /
    • 2008
  • To apply the appropriate new grounding system to domestic power system, safety has to be guaranteed under the given circumstances. It is not possible to decide the safety of grounding systems by the experimental test because safety experiments directly relate to the human life and the installed electric machines. Therefore, the computer simulation program to decide the safety of grounding systems based on the IEC standard systems, has to be developed. This paper proposes the computer simulation based method to decide the safety of grounding system with the concepts of touch voltage, step voltage, human resistivity, and applied electric current according to the several conditions of human body located in the corresponding grounding systems. The proposed method is implemented by Matlab/Simulink and Visual C++ programming tools for its visualization.