• 제목/요약/키워드: Total ionizing dose effect

검색결과 30건 처리시간 0.031초

즉발감마선에 의한 상용전자소자의 피해현상분석 연구 (The Study of Transient Radiation Effects on Commercial Electronic Devices)

  • 오승찬;이남호;이흥호
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1448-1453
    • /
    • 2012
  • In this study, we carried out transient radiation test for identify failure situation by a transient radiation effect on operational amplifier devices. This experiments were carried out using a 60 MeV electron beam pulse of the LINAC(Linear Accelerator) facility in the Pohang Accelerator Laboratory. In this test, we has found that a serious failure as a burn-out effect due to overcurrent on the partial electronic devices.

Radiation-hardened-by-design preamplifier with binary weighted current source for radiation detector

  • Minuk Seung;Jong-Gyun Choi ;Woo-young Choi;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.189-194
    • /
    • 2024
  • This paper presents a radiation-hardened-by-design preamplifier that utilizes a self-compensation technique with a charge-sensitive amplifier (CSA) and replica for total ionizing dose (TID) effects. The CSA consists of an operational amplifier (OPAMP) with a 6-bit binary weighted current source (BWCS) and feedback network. The replica circuit is utilized to compensate for the TID effects of the CSA. Two comparators can detect the operating point of the replica OPAMP and generate appropriate signals to control the switches of the BWCS. The proposed preamplifier was fabricated using a general-purpose complementary metal-oxide-silicon field effect transistor 0.18 ㎛ process and verified through a test up to 230 kGy (SiO2) at a rate of 10.46 kGy (SiO2)/h. The code of the BWCS control circuit varied with the total radiation dose. During the verification test, the initial value of the digital code was 39, and a final value of 30 was observed. Furthermore, the preamplifier output exhibited a maximum variation error of 2.39%, while the maximum rise-time error was 1.96%. A minimum signal-to-noise ratio of 49.64 dB was measured.

Study on changes in electrical and switching characteristics of NPT-IGBT devices by fast neutron irradiation

  • Hani Baek;Byung Gun Park;Chaeho Shin;Gwang Min Sun
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3334-3341
    • /
    • 2023
  • We studied the irradiation effects of fast neutron generated by a 30 MeV cyclotron on the electrical and switching characteristics of NPT-IGBT devices. Fast neutron fluence ranges from 2.7 × 109 to 1.82 × 1013 n/cm2. Electrical characteristics of the IGBT device such as I-V, forward voltage drop and additionally switching characteristics of turn-on and -off were measured. As the neutron fluence increased, the device's threshold voltage decreased, the forward voltage drop increased significantly, and the turn-on and turn-off time became faster. In particular, the delay time of turn-on switching was improved by about 35% to a maximum of about 39.68 ns, and that of turn-off switching was also reduced by about 40%-84.89 ns, showing a faster switching.

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

Antioxidant Activity of Gamma-Irradiated Asparagus cochinchinensis (Asparagi radix) (Lour.) Merr. Extract and Inhibition Effect on Lipid Oxidation of Emulsion-Type Pork Sausage

  • Cho, Young Ho;Yang, Myung-Soon
    • 한국축산식품학회지
    • /
    • 제38권6호
    • /
    • pp.1196-1202
    • /
    • 2018
  • The objective of this study was to determine the antioxidant activity of gamma-irradiated Asparagus cochinchinensis (Asparagi radix) (Lour.) Merr. Extract (ARE) and its inhibition effect on food lipid oxidation using emulsion-type pork sausage as a model. ARE was prepared from dried Asparagi radix root and ARE solution (1.0 g/mL) was gamma-irradiated with designated doses at 5, 10, and 20 kGy. Antioxidant activity of ARE solution was determined by measuring 1,1-diphenyl-e-picrylhydrazyl (DPPH) and 2,2'-azino-bis (3-ethylbenzothiazoline-9-sulphonic acid) (ABTS) radicals. Activities of DPPH and ABTS radicals were decreased, whereas total phenolic contents increased after gamma irradiation with a dose dependence. Addition of gamma-irradiated ARE dose-dependently retarded lipid oxidation of emulsion-type pork sausage during storage at $4^{\circ}C$. These results indicated that gamma-irradiated ARE might have antioxidant activity more than non-irradiated ARE due to increase of the content of polyphenolic compounds by ionizing radiation.

발아억제 선량의 전리에너지가 마늘의 성분변화에 미치는 영향 (Chemical Changes in Garlic Bulbs Resulting from Ionizing Energy Treatment at Sprout-Inhibition Dose)

  • 권중호;윤형식;변명우;조한옥
    • Applied Biological Chemistry
    • /
    • 제31권2호
    • /
    • pp.147-153
    • /
    • 1988
  • 마늘의 품질보존을 위한 수단으로서 전리에너지인 장마선의 이응이 가능해짐에 따라, 발아억제 선량인 0.1kGy 처리와 저장조건$(3{\pm}1^{\circ}C,\;75{\sim}85%\;R.H.;\;12{\pm}5^{\circ}C,\;75{\sim}85%\;R.H.)$이 마늘의 몇가지 성분변화에 미치는 영향을 조사하였다. 0.1kGy의 감마선 조사는 시료의 수분함량에 거의 영향을 미치지 않았으나 실온저장 10개월 후의 대조시료는 조사시료에 비해 수분함량이 유의적으로 감소되었다(P<0.05). 발아억제 처리는 저장중 시료의 총당 함량의 변화를 완만하게 하였으며, 저온저장 8개월 후 대조시료의 유리당 함량은 조사시료에 비해 유의적으로 증가되었다. 발아억제 선량의 감마선 처리는 시료의 아스코르브산과 지방산 참량에 거의 영향을 주지 않았으나 아미노산 조성중 글루탐산과 아스파르트산 함량에는 영향을 미치는 것으로 나타났다.

  • PDF

Temperature determines post-harvest quality of spinach leaves after gamma irradiation

  • Kim, Jin-Hong;Kim, Ji Hong;Lee, Min Hee;Kim, Jin Kyu;Chung, Byung Yeoup
    • Rapid Communication in Photoscience
    • /
    • 제3권1호
    • /
    • pp.25-27
    • /
    • 2014
  • The relative importance of radiation dose, storage time, and temperature in radiation processing of spinach (Spinacia oleracea L.), was evaluated in terms of the postharvest quality through a model study using leaf disks. Physiological activity and chlorophyll and carotenoid contents were measured to represent the postharvest quality (in terms of external appearance) of spinach, a leafy green vegetable. At $22^{\circ}C$ and $30^{\circ}C$, the higher gamma-radiation dose caused a greater decrease in the physiological activity, depending on the storage time of 4 d. However, this decrease was not significant at $4^{\circ}C$ and $15^{\circ}C$. Total chlorophyll and carotenoid contents were substantially decreased by 3 kGy at $15^{\circ}C$, and dose-dependently by 0.5-3 kGy at $22^{\circ}C$. In contrast, the proportion of lutein in total carotenoid was significantly increased in the 2-3-kGy samples only at $22^{\circ}C$, while that of ${\beta}$-carotene was slightly decreased, indicating progression of leaf aging. These data suggest that the unfavorable effect of gamma irradiation on the postharvest quality of spinach could be avoided or controlled by the storage time or temperature rather than the radiation dose. The current study could be available to improve radiation processing of other leafy green vegetables.

우주방사선 환경 ICT 소자 영향 및 개발 동향 (ICT Device Impacts and Development Trends on Cosmic Radiation Environment)

  • 이윤식;정성근;황인록;양용석;이명래;서동우
    • 전자통신동향분석
    • /
    • 제37권2호
    • /
    • pp.21-29
    • /
    • 2022
  • Cosmic radiation environments having extremely high-energy particles and photons cause severe malfunctions of electrical components in space and terrestrial regions. In this study, we revisit basic knowledge on radiation effects in ICT electrical devices, such as single event effect, total ionizing dose, and displacement damage. To avoid such soft errors and system failures, we introduce essential technical approaches from the perspectives of materials, layouts, circuits, and systems, including current research trends. By considering several techniques and Space EEE part standards, we suggest possible directions that can invoke New Space Era technology.

Reduced Ovarian Cancer Incidence in Women Exposed to Low Dose Ionizing Background Radiation or Radiation to the Ovaries after Treatment for Breast Cancer or Rectosigmoid Cancer

  • Lehrer, Steven;Green, Sheryl;Rosenzweig, Kenneth E
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권6호
    • /
    • pp.2979-2982
    • /
    • 2016
  • Background: High dose ionizing radiation can induce ovarian cancer, but the effect of low dose radiation on the development of ovarian cancer has not been extensively studied. We evaluated the effect of low dose radiation and total background radiation, and the radiation delivered to the ovaries during the treatment of rectosigmoid cancer and breast cancer on ovarian cancer incidence. Materials and Methods: Background radiation measurements are from Assessment of Variations in Radiation Exposure in the United States, 2011. Ovarian cancer incidence data are from the Centers for Disease Control and Prevention. Standardized incidence ratios (SIR) of ovarian cancer following breast cancer and rectosigmoid cancer are from Surveillance, Epidemiology, and End Results (SEER) data. Obesity data by US state are from the Centers for Disease Control and Prevention. Mean ages of US state populations are from the United States Census Bureau. Results: We calculated standardized incidence ratios (SIR) from Surveillance, Epidemiology, and End Results (SEER) data, which reveal that in 194,042 cases of breast cancer treated with beam radiation, there were 796 cases of ovarian cancer by 120+ months of treatment (0.41%); in 283, 875 cases of breast cancer not treated with radiation, there were 1,531 cases of ovarian cancer by 120+ months (0.54%). The difference in ovarian cancer incidence in the two groups was significant (p < 0.001, two tailed Fisher exact test). The small dose of scattered ovarian radiation (about 3.09 cGy) from beam radiation to the breast appears to have reduced the risk of ovarian cancer by 24%. In 13,099 cases of rectal or rectosigmoid junction cancer treated with beam radiation in the SEER data, there were 20 cases of ovarian cancer by 120+ months of treatment (0.15%). In 33,305 cases of rectal or rectosigmoid junction cancer not treated with radiation, there were 91 cases of ovarian cancer by 120+ months (0.27%). The difference in ovarian cancer incidence in the two groups was significant (p = 0.017, two tailed Fisher exact test). In other words, the beam radiation to rectum and rectosigmoid that also reached the ovaries reduced the risk of ovarian cancer by 44%. In addition, there was a significant inverse relationship between ovarian cancer in white women and radon background radiation (r = - 0.465. p = 0.002) and total background radiation (r = -0.456, p = 0.002). Because increasing age and obesity are risk factors for ovarian cancer, multivariate linear regression was performed. The inverse relationship between ovarian cancer incidence and radon background was significant (${\beta}=-0.463$, p = 0.002) but unrelated to age (${\beta}=-0.080$, p = 0.570) or obesity (${\beta}=-0.180$, p = 0.208). Conclusions: The reduction of ovarian cancer risk following low dose radiation may be the result of radiation hormesis. Hormesis is a favorable biological response to low toxin exposure. A pollutant or toxin demonstrating hormesis has the opposite effect in small doses as in large doses. In the case of radiation, large doses are carcinogenic. However, lower overall cancer rates are found in U.S. states with high impact radiation. Moreover, there is reduced lung cancer incidence in high radiation background US states where nuclear weapons testing was done. Women at increased risk of ovarian cancer have two choices. They may be closely followed (surveillance) or undergo immediate prophylactic bilateral salpingo-oophorectomy. However, the efficacy of surveillance is questionable. Bilateral salpingo-oophorectomy is considered preferable, although it carries the risk of surgical complications. The data analysis above suggests that low-dose pelvic irradiation might be a good third choice to reduce ovarian cancer risk. Further studies would be worthwhile to establish the lowest optimum radiation dose.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.