• Title/Summary/Keyword: Total hip revision

Search Result 15, Processing Time 0.021 seconds

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty

  • Hyun Sik Shin;Dong-Hong, Kim;Hyung Seok Kim;Hyung Seob Ahn;Yeesuk Kim
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.233-237
    • /
    • 2023
  • Purpose: The objective of this study was to analyze the results from a cohort of patients who underwent a revision total hip arthroplasty (THA) using a dual mobility cup (DMC) implant. Materials and Methods: A retrospective review of revised THAs was conducted using the database from a single tertiary referral hospital. A total of 91 revision THAs from 91 patients were included in the study. There were 46 male hips and 45 female hips. The mean age was 56.3±14.6 years, and the mean follow-up period was 6.4±5.9 years. In performance of revision THAs, the DMC implants were used in 18 hips (19.8%), and the conventional implants were used in 73 hips (80.2%). Results: During the follow-up period, three dislocations were identified, and the overall dislocation rate was 3.3%. Early dislocation (at one month postoperatively) occurred in one patient, while late dislocation (at a mean of 7.5 years) occurred in two patients. There was no occurrence of dislocation in the DMC group (0%), and three dislocations were detected in the conventional group (4.1%). However, no significant difference in the rate of dislocation was observed between the two groups (P=0.891). Conclusion: Although the rate of dislocation was higher in the conventional group, there were no statistically significant differences between the two groups due to the small number of patients. Nevertheless, we believe that the dual mobility design is advantageous in terms of reducing dislocation rate and can be recommended as an option for a revision THA.

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.

Comparative Analysis of the Stress and Strain of Material for Revision Total Hip Replacement (고관절 재치환술시 재료의 응력과 변형률의 비교 분석)

  • Shim D.H.;Kim J.H.;Ko S.H.;Kim K.H.;Kim D.Y.;Choi M.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.511-512
    • /
    • 2006
  • According to development of medical science and engineering, people has made efforts to solve tile discomfort of body accident as well as the life span. Many cases that reduce pain of a hip joint or limitation of motion using Revision Total Hip Replacement are getting increased. However it has not proved which material is the most appropriate. Scientists are still studying about materials of the artificial joint. In accordance with advance of science, the materials are Betting better. Recently, when Revision Total Hip Replacement is performed, typical materials are Ti-alloys Ceramics. We have studied materials of artificial joints and analyzed which one is better for human's body.

  • PDF

Clinical and Functional Outcomes of the Exeter V40 Short Stem in Primary and Revision Arthroplasty: Does the Indication Affect Outcomes in the Short Term?

  • Nemandra Amir Sandiford;Scott M. Bolam;Irrum Afzal;Sarkhell Radha
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.40-46
    • /
    • 2023
  • Purpose: A variety of short Exeter stems designed specifically for use in performance of total hip arthroplasty (THA) in primary and revision settings have recently been introduced. Some have been used 'off label' for hip reconstruction. The aim of this study is to report clinical and radiological results from the Exeter V40 125 mm stem in performance of primary THA and revision THA. Materials and Methods: This study had a retrospective design. Insertion of 58 (24 primary, 34 revision) Exeter V40 125 mm stems was performed between 2015 and 2017. The minimum follow-up period was two years. Assessment of the Oxford hip score (OHS), EuroQol-5 Dimension (EQ-5D), and radiological follow-up was performed at one and two years. Results: In the primary group, the preoperative, mean OHS was 13.29. The mean OHS was 32.86 and 23.39 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were at 0.14, 0.59, and 0.35, preoperatively, at one-year follow-up and two-year follow-up, respectively. In the revision group, the mean preoperative OHS was 19.41. The mean OHS was 30.55 and 26.05 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were 0.33, 0.61, and 0.48 preoperatively, at one-year follow-up and two-year follow-up, respectively. No progressive or new radiolucent lines were observed around any stem at the time of the final follow-up in all patients in both groups. Conclusion: Encouraging results regarding use of Exeter V40 125 mm stems have been reported up to two years following surgery in primary and revision THA settings.

Preoperative Serum Albumin Levels Predict Treatment Cost in Total Hip and Knee Arthroplasty

  • Rudasill, Sarah E.;Ng, Andrew;Kamath, Atul F.
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.398-406
    • /
    • 2018
  • Background: Hypoalbuminemia (serum albumin < 3.5 g/dL) is associated with increased morbidity and mortality in patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, costs associated with hypoalbuminemia remain unknown. This study investigated the effect of serum albumin on direct treatment costs, length of stay (LOS), and readmissions for primary and revision THA and TKA patients. Methods: All adult patients at a single institution undergoing primary or revision THA or TKA between January 2014 and December 2016 were retrospectively reviewed. Patients were stratified by preoperative serum albumin level. The primary outcome was total direct costs at index hospitalization. Secondary outcomes included LOS and readmission within 30 days. Multivariable regressions were utilized to adjust for demographics and comorbidities. Results: Of 3,785 patients, 114 (3.0%) had hypoalbuminemia. After adjustment, hypoalbuminemia was associated with a 16.2% increase in costs (${\beta}=0.162$; 95% confidence interval [CI], 0.112 to 0.213; p < 0.001), representing an average cost increase of $3,383 (95% CI, $2,281 to $4,485) relative to costs for serum albumin > 4.5 g/dL. The increased total costs were significantly higher in revision ($4,322, p = 0.034) than in primary ($3,446, p < 0.001) procedures. In adjusted regression, each 1.0 g/dL increase in serum albumin yielded a 6.6% reduction in costs (${\beta}=-0.066$; 95% CI, -0.090 to -0.042]; p < 0.001), for average savings of $1,282 (95% CI, $759 to $1,806) per unit albumin. Adjusted regressions demonstrated that a 1-point increase in serum albumin reduced readmissions by 53% (odds ratio, 0.47; 95% CI, 0.31-0.73; p = 0.001) and LOS by 0.6 days (${\beta}=-0.60$; 95% CI, -0.76 to -0.44; p < 0.001). Conclusions: Hypoalbuminemia is associated with increased total direct costs, LOS, and readmissions following primary and revision THA and TKA. Future efforts to predict and address total costs should take into consideration the patient's preoperative serum albumin levels.

Functional Outcome after Reimplantation in Patients Treated with and without an Antibiotic-Loaded Cement Spacers for Hip Prosthetic Joint Infections

  • Michele Fiore;Claudia Rondinella;Azzurra Paolucci;Lorenzo Morante;Massimiliano De Paolis;Andrea Sambri
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.32-39
    • /
    • 2023
  • Purpose: A staged revision with placement of a temporary antibiotic-loaded cement spacer after removal of the implant is the "gold standard" for treatment of chronic prosthetic joint infection (PJI). It enables local delivery of antibiotics, maintenance of limb-length and mobility, easier reimplantation. However, bacterial colonization of spacers and mechanical complications can also occur. The aim of this study is to evaluate functional results and infection control in two-stage treatment of total hip arthroplasty (THA) PJI with and without a spacer. Materials and Methods: A retrospective review of 64 consecutive patients was conducted: 34 underwent two-stage revision using a cement spacer (group A), 30 underwent two-stage revision without a spacer (group B). At the final follow-up, functional evaluation of patients with a THA in site, without PJI recurrence, was performed using the Harris hip score (HHS). Measurement of limb-length and off-set discrepancies was performed using anteroposterior pelvic X-rays. Results: Most patients in group B were older with more comorbidities preoperatively. Thirty-three patients (97.1%) in group A underwent THA reimplantation versus 22 patients (73.3%) in group B (P<0.001). No significant differences in limb-length and off-set were observed. The results of functional evaluation performed during the final follow-up (mean, 41 months) showed better function in patients in group A (mean HHS, 76.3 vs. 55.9; P<0.001). Conclusion: The use of antibiotic-loaded cement spacer seems superior in terms of functional outcomes and reimplantation rate. Resection arthroplasty might be reserved as a first-stage procedure in patients who are unfit, who might benefit from a definitive procedure.

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.

Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

  • Mathias van den Broek;Kris Govaers
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.54-61
    • /
    • 2023
  • Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.